Search results for "SCOPE"
showing 10 items of 2420 documents
Zvaigžņotā Debess: 2009, Pavasaris (203)
2009
Contents: E.R.Mustel, President of the Astronomical Council of the USSR Academy of Sciences. Congratulations to Editorial Board of “Zvaigžņotā debess” ; Z.Alksne. Gould’s Belt ; I.Daube. At the Radioastrophysical Observatory of the Latvian Academy of Sciences ; Z.Alksne, A.Alksnis. Lopsided Galaxies ; A.Alksnis. HII Region Gum 29 – a Stellar Nursery ; D.Docenko. On Collision of Asteroid 2008 TC3 with the Earth ; V.Lapoška. On „Leap Second” ; I.Vilks, M.Gills. Beginning of the International Year of Astronomy in Paris: Impressions by Latvian Delegates ; J.Jaunbergs. Equatorial Ridge on Iapetus ; M.Sudārs. Space Shuttle Is Not Likely to Retire Next Year ; I.Vilks. Planet Satellite Names in Lat…
Surface structure determination by SEM image processing and electrochemical impedance of graphite+polyethylene composite electrodes
2004
Abstract The electrochemical impedance behaviour of heterogeneous or/and rough electrodes has usually been associated with some geometrical parameters of the surface structure or to a statistical description of the surface properties. An experimental method for sample preparation of graphite + polyethylene composite electrodes based on plasma etching is proposed. After plasma etching, the statistical properties of the electrode, such as the graphite particle size distribution and fractional coverage are measured from scanning electron microscopy pictures using image processing software. The statistical information obtained for the surface is combined with impedance equations of independent …
Localization of antigens PwA33 and La on lampbrush chromosomes and on nucleoplasmic structures in the oocyte of the urodele Pleurodeles waltl: Light …
1994
Monoclonal antibodies A33/22 and La11G7 have been used to study the distribution of the corre-sponding antigens, PwA33 and La, on the lampbrush chromosome loops and nucleoplasmic structures of P. waltl oocytes, using immunofluorescence, confocal laser scanning microscopy and immunogold labeling. The results obtained with these antibodies have been compared with those obtained with the Sm-antigen-specific monoclonal antibody Y12. All these monoclonal antibodies (mAbs) labeled the matrices of the majority of normal loops along their whole length. Nucleoplasmic RNP granules showed a strong staining with the mAbs La11G7 and Y12 throughout their mass, but with the mAb A33/22, they showed only a …
The INTEGRAL IBIS/ISGRI System Point Spread Function and Source Location Accuracy
2003
The imager on board INTEGRAL (IBIS) presently provides the most detailed sky images ever obtained at energies above 30 keV. The telescope is based on a coded aperture imaging system which allows to obtain sky images in a large field of view 29deg x 29deg with an angular resolution of 12'. The System Point Spread Function of the telescope and its detailed characteristics are here described along with the specific analysis algorithms used to derive the accurate point-like source locations. The derived location accuracy is studied using the first in-flight calibration data on strong sources for the IBIS/ISGRI system. The dependence of the calibrated location accuracy with the signal to noise r…
Flux and color variations of the quadruply imaged quasar HE 0435-1223
2011
aims: We present VRi photometric observations of the quadruply imaged quasar HE 0435-1223, carried out with the Danish 1.54m telescope at the La Silla Observatory. Our aim was to monitor and study the magnitudes and colors of each lensed component as a function of time. methods: We monitored the object during two seasons (2008 and 2009) in the VRi spectral bands, and reduced the data with two independent techniques: difference imaging and PSF (Point Spread Function) fitting.results: Between these two seasons, our results show an evident decrease in flux by ~0.2-0.4 magnitudes of the four lensed components in the three filters. We also found a significant increase (~0.05-0.015) in their V-R …
Quasi-spherical focal spot in two-photon scanning microscopy by three-ring apodization
2005
International audience; We present a beam-shaping technique for two-photon excitation (TPE) fluorescence microscopy. We show that by inserting a properly designed three-ring pupil filter in the illumination beam of the microscope, the effective optical sectioning capacity of such a system improves so that the point spread function gets a quasi-spherical shape. Such an improvement, which allows the acquisition of 3D images with isotropic quality, is obtained at the expense of only a small increase of the overall energy in the axial sidelobes. The performance of this technique is illustrated with a scanning TPE microscopy experiment in which the image of small beads is obtained. We demonstrat…
Fast multi-directional DSLM for confocal detection without striping artifacts
2020
In recent years light-sheet fluorescence microscopy (LSFM) has become a cornerstone technology for neuroscience, improving the quality and capabilities of 3D imaging. By selectively illuminating a single plane, it provides intrinsic optical sectioning and fast image recording, while minimizing out of focus fluorescence background, sample photo-damage and photo-bleaching. However, images acquired with LSFM are often affected by light absorption or scattering effects, leading to un-even illumination and striping artifacts. In this work we present an optical solution to this problem, via fast multi-directional illumination of the sample, based on an acousto-optical deflector (AOD). We demonstr…
Axial resolution in two-color excitation fluorescence microscopy by phase-only binary apodization
2005
We study the effect of a kind of binary phase-only filters, the Toraldo filters, in two-color excitation fluorescence microscopy. We show that by simple insertion of a properly designed Toraldo filter in one of the illumination arms the axial resolution of the system is significantly improved. Specifically, the main peak of the point spread function is narrowed by 22% along the axial direction.
Long working range light field microscope with fast scanning multifocal liquid crystal microlens array
2018
The light field microscope has the potential of recording the 3D information of biological specimens in real time with a conventional light source. To further extend the depth of field to broaden its applications, in this paper, we proposed a multifocal high-resistance liquid crystal microlens array instead of the fixed microlens array. The developed multifocal liquid crystal microlens array can provide high quality point spread function in multiple focal lengths. By adjusting the focal length of the liquid crystal microlens array sequentially, the total working range of the light field microscope can be much extended. Furthermore, in our proposed system, the intermediate image was placed i…
Sidelobe decline in single-photon 4Pi microscopy by Toraldo rings.
2003
We demonstrate theoretically the feasibility of single-photon 4Pi-confocal microscopy. By inserting a pair of properly designed multi-ring phase-only pupil filters in the illumination path of a 4Pi microscope the height of the sidelobes of the point spread function substantially reduced, so that there is no ambiguity in the 3D image. Then, an axial resolution up to four times higher than that of single-photon confocal microscope can be effectively achieved.