Search results for "SOUND"

showing 10 items of 1845 documents

Muscle‐tendon morphology and function following long‐term exposure to repeated and strenuous mechanical loading

2020

We mapped structural and functional characteristics of muscle‐tendon units in a population exposed to very long‐term routine overloading. Twenty‐eight military academy cadets (age: 21.00 ± 1.1 yrs; height: 176.1 ± 4.8 cm; mass: 73.8 ± 7.0 kg) exposed for over 24 months to repetitive overloading were profiled via ultrasonography with a senior subgroup of them (n = 11; age = 21.4 ± 1.0 yrs; height = 176.5 ± 4.8 cm; mass = 71.4 ± 6.6 kg) also tested while walking and marching on a treadmill. A group of eleven ethnicity‐ and aged‐matched civilians (age = 21.6 ± 0.7 yrs; height = 176.8 ± 4.3 cm; mass = 74.6 ± 5.6 kg) was also profiled and tested. Cadets and civilians exhibited similar morphology…

rasitusultrasoundlihaksetylikuormitusfascicle mechanicsoverloadingjänteetmarchinghermo-lihastoimintamedial gastrocnemiustriceps suraefaskiatbiomekaniikkahuman activitiespatellar tendon
researchProduct

Perceived differences in recordings produced with four 5.0 surround microphone techniques

2007

recordingäänentoistolaitteetlistening testmicrophone techniquesmikrofonitsurround sound
researchProduct

Choroidal thickness in glaucoma patients and glaucoma suspects measured by spectral domain coherence optical tomography

2012

Purpose: The aim of our study was to evaluate and compare retro-foveolar choroidal thickness (RFCT) of healthy subjects, individuals with intraocular hypertension, patients with primary open-angle glaucoma (POAG), patients with normal tension glaucoma (NTG) and patients with primary angle-closure glaucoma (PACG) by spectral domain optical coherence tomography (SD-OCT).Methods: Sixty-five healthy eyes, 30 eyes with intraocular hypertension, 90 eyes with POAG, 30 eyes with NTG and 20 eyes with PACG were included in this cross-sectional study. RFCT, foveolar retinal thickness and average retinal nerve fiber layer thickness (RNFL) were measured by SD-OCT (Spectralis HRA-OCT, Heidelberg Engineer…

retinaFA584 macula/foveagenetic structuresophtalmologieSLOtomography[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathology[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansICG[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologyœileye diseasestomographieultrasound)ophthalmologyRTAglaucomaOCT[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs[ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory Organsglaucome551 imaging methods (CTsense organs[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology452 choroidMRI
researchProduct

Ultrasound bioeffects in rats: quantification of cellular damage in the fetal liver after pulsed Doppler imaging

2011

Objective To determine whether pulsed Doppler examination of the ductus venosus in rat fetuses could damage exposed tissue. Methods On gestational day 18, the livers of a mean of approximately five fetuses per mother (n = 5.14, SD = 1.6), in a cohort of 35 pregnant female rats, were exposed individually to pulsed Doppler and these were considered the 'exposed group'. The remaining fetuses in each pregnant rat (n = 5.16, SD = 2.1) formed the 'control group'. We tested for 600, 300, 60, 20, 15, 10 and 3 s of exposure of the fetal ductus venosus and the damage was evaluated measuring a cell death index of apoptotic activity at 7 h post-exposure (n = 16). In addition, subgroups of mothers were …

safetyPathologymedicine.medical_specialtyTime FactorsApoptosisWistar ratUltrasonography Prenatalductus venousFetusPregnancymedicineAnimalsRadiology Nuclear Medicine and imagingRats WistarVeinFetusPregnancyPulsed dopplerRadiological and Ultrasound Technologybusiness.industryUltrasoundDopplerObstetrics and GynecologyGeneral Medicinemedicine.diseaseRatsmedicine.anatomical_structureLiverReproductive MedicineUltrasonography Doppler PulsedApoptosisGestationFemalebusinessDuctus venosus
researchProduct

Functional outcomes of peripheral nerve repair and regeneration: clinical and experimental study

This study investigated pre- and post-operative evaluation of peripheral nerve injuries and functional outcomes of peripheral nerve regeneration after different type of injuries and different type of treatments. Neuromas/scar neuritis and brachial plexus injuries are specifically addressed; literature and experimental evidence on the outcomes of vascularized nerve grafts are presented.

scar neuritisnerve regeneration; vascularized nerve grafts; brachial plexus injuries; nerve ultrasound; neuroma; scar neuritisnerve ultrasoundSettore MED/19 - Chirurgia Plasticaneuromavascularized nerve graftnerve regenerationbrachial plexus injurie
researchProduct

A Shape-based Statistical Method to Retrieve 2D TRUS-MR Slice Correspondence for Prostate Biopsy

2012

International audience; This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to per…

shape-contextProstate biopsyComputer science[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030230 surgeryTranslation (geometry)[ INFO.INFO-CV ] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]urologic and male genital diseasesRectal ultrasound030218 nuclear medicine & medical imagingProstate biopsy03 medical and health sciences0302 clinical medicine[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]ProstateBiopsymedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingComputer visionnormalized mutual information.normalized mutual informationmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industry[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Magnetic resonance imagingTissue samplingmedicine.anatomical_structure2D TRUS/3D MR correspondenceArtificial intelligenceUltrasonographybusiness
researchProduct

Vecākā pirmsskolas vecuma bērnu skaņu izrunas pilnveides sekmēšana grāmatu gatavošanas procesā

2019

Kvalifikācijas darbs ir izstrādāts par tematu „Vecākā pirmsskolas vecuma bērnu skaņu izrunas pilnveide grāmatu gatavošanas procesā” Kvalifikācijas darba autore: Mārīte Aldere Darbā izvēlētā temata aktualitāte pamatojama ar to , ka kopā gatavotās spēles un grāmatas, bērnos izraisa pozitīvas emocijas un sekmē ne tikai bērnu runāt prasmi, bet attīsta arī citas dzīvē nepieciešamās prasmes, tādēļ būtiski izpētīt kā skaņu izrunas pilnveidi var sekmēt ar grāmatas gatavošanas procesu. Pētījuma mērķis: Veikt teorētisku un praktisku pētījumu par 5-6 gadus vecu bērnu skaņas izrunu, izmantojot grāmatas, tapšanas procesu. Pētījums sastāv no divām daļām – teorētiskā un empīriskā pētījuma. Pētījuma teorēt…

skaņas izrunasound phonic pronunciationPirmsskolas pedagoģijapedagoģiskais processgrāmatavecākā pirmsskolas vecuma bērnni
researchProduct

miMic

2016

miMic, a sonic analogue of paper and pencil is proposed: An augmented microphone for vocal and gestural sonic sketching. Vocalizations are classified and interpreted as instances of sound models, which the user can play with by vocal and gestural control. The physical device is based on a modified microphone, with embedded inertial sensors and buttons. Sound models can be selected by vocal imitations that are automatically classified, and each model is mapped to vocal and gestural features for real-time control. With miMic, the sound designer can explore a vast sonic space and quickly produce expressive sonic sketches, which may be turned into sound prototypes by further adjustment of model…

sonic interaction design system architecture vocal sketching sound designSound (medical instrument)Settore INF/01 - InformaticaInformationSystems_INFORMATIONINTERFACESANDPRESENTATION(e.g.HCI)Computer scienceMicrophoneSound designSpeech recognition05 social sciencesModel parameterssystem architecturevocal sketchingsonic interaction designAugmented microphone050105 experimental psychologysound designGestureInertial measurement unitSonic interaction designSettore ICAR/13 - Disegno Industriale0501 psychology and cognitive sciences050107 human factorsPencil (mathematics)GestureProceedings of the TEI '16: Tenth International Conference on Tangible, Embedded, and Embodied Interaction
researchProduct

Soundscape design through evolutionary engines

2008

Abstract Two implementations of an Evolutionary Sound Synthesis method using the Interaural Time Difference (ITD) and psychoacoustic descriptors are presented here as a way to develop criteria for fitness evaluation. We also explore a relationship between adaptive sound evolution and three soundscape characteristics: keysounds, key-signals and sound-marks. Sonic Localization Field is defined using a sound attenuation factor and ITD azimuth angle, respectively (Ii, Li). These pairs are used to build Spatial Sound Genotypes (SSG) and they are extracted from a waveform population set. An explanation on how our model was initially written in MATLAB is followed by a recent Pure Data (Pd) impleme…

sonic spatializationeducation.field_of_studySoundscapesound synthesisGeneral Computer Scienceartificial evolutionComputer scienceSpeech recognitionacoustic descriptorsPopulationEvolutionary algorithmInteraural time differencegenetic algorithmsPure DataPsychoacousticseducationcomputerAcoustic attenuationParametric statisticscomputer.programming_languageComputer Science(all)
researchProduct

Shoulder ultrasound: current concepts and future perspectives

2021

Ultrasonography is an established and effective imaging technique that can be used to evaluate articular and periarticular structures around the shoulder. It has been shown to be useful in a wide range of rotator cuff diseases (e.g. tendon tears, rotator cuff calcific tendinopathy and bursitis) as well as non-rotator cuff abnormalities (instability, synovial joint diseases and nerve entrapment syndrome). A scanning protocol is highly recommended to reduce the rate of operators’ errors by following a standardized scheme including a list of main structures. Shoulder ultrasound has several advantages: it is a relatively cheap and widely available technique, free from ionizing radiation, that c…

sonographymusculoskeletal diseasesmedicine.medical_specialtyPercutaneousRadiological and Ultrasound Technologymedicine.diagnostic_testBursitisultrasoundshoulderbusiness.industryUltrasoundMagnetic resonance imagingTendonitismedicine.diseasemedicine.anatomical_structureSynovial jointCuffmedicineMedicineRadiology Nuclear Medicine and imagingRotator cuffRadiologybusinessJournal of Ultrasonography
researchProduct