Search results for "SPECTROSCOPY"
showing 10 items of 10293 documents
Early imaging predicts later cognitive impairment in primary progressive multiple sclerosis
2010
Background: Cognitive impairment in primary progressive multiple sclerosis (PPMS) is common and correlates modestly with contemporary lesion burden and brain volume. Using a cohort/case control methodology, we explore the ability of MRI abnormalities, including those in the normal-appearing brain tissue, to predict future cognitive dysfunction in PPMS. Methods: Thirty-one patients recruited into a longitudinal study within 5 years of onset of PPMS were assessed neuropsychologically on average 5.5 years later along with 31 matched healthy controls. MRI data obtained at entry into the study (lesion metrics, brain volumes, magnetization transfer ratio histogram metrics, and magnetic resonance …
Resistance Training Induces Antiatherogenic Effects on Metabolomic Pathways
2019
INTRODUCTION Arising evidence suggests that resistance training has the potential to induce beneficial modulation of biomarker profile. To date, however, only immediate responses to resistance training have been investigated using high-throughput metabolomics whereas the effects of chronic resistance training on biomarker profile have not been studied in detail. METHODS A total of 86 recreationally active healthy men without previous systematic resistance training background were allocated into (i) a resistance training (RT) group (n = 68; age, 33 ± 7 yr; body mass index, 28 ± 3 kg·m) and (ii) a non-RT group (n = 18; age, 31 ± 4 yr; body mass index, 27 ± 3 kg·m). Blood samples were collecte…
Prognosis Biomarkers of Severe Sepsis and Septic Shock by 1H NMR Urine Metabolomics in the Intensive Care Unit.
2015
Early diagnosis and patient stratification may improve sepsis outcome by a timely start of the proper specific treatment. We aimed to identify metabolomic biomarkers of sepsis in urine by (1)H-NMR spectroscopy to assess the severity and to predict outcomes. Urine samples were collected from 64 patients with severe sepsis or septic shock in the ICU for a (1)H NMR spectra acquisition. A supervised analysis was performed on the processed spectra, and a predictive model for prognosis (30-days mortality/survival) of sepsis was constructed using partial least-squares discriminant analysis (PLS-DA). In addition, we compared the prediction power of metabolomics data respect the Sequential Organ Fai…
MRS SHOWS ABNORMALITIES BEFORE SYMPTOMS IN FAMILIAL ALZHEIMER DISEASE
2006
Background: Pathologic change in Alzheimer disease (AD) begins some years before symptoms. MRS has the potential to detect metabolic abnormalities reflecting this early pathologic change. Presenilin 1 (PS1) and amyloid precursor protein (APP) mutation carriers have a nearly 100% risk of developing AD and may be studied prior to symptom onset. Methods: Short echo time proton MR spectra were acquired from a midline posterior cingulate voxel in presymptomatic carriers of PS1 or APP mutations (“presymptomatic mutation carriers” [PMCs]; n = 7) and age- and sex-matched control subjects (n = 6). Ratios of N-acetyl aspartate (NAA), myo-inositol (MI), and choline-containing compounds (Cho) to creati…
Differential Effects of Dry Eye Disorders on Metabolomic Profile by 1H Nuclear Magnetic Resonance Spectroscopy
2014
We used1H NMR spectroscopy to analyze the metabolomic profile of reflex tears from patients with dry eye disorders (DEDs). 90 subjects were divided into 2 groups: (1) patients with DEDs (DEDG;n = 55) and (2) healthy subjects (CG;n = 35). Additionally, the DEDG was subdivided into 2 subgroups based on DED severity: mild-to-moderate and moderate (n = 22andn = 33, resp.). Personal interviews and systematized ophthalmologic examinations were carried out. Reflex tears (20–30 μL) were collected by gently rubbing in the inferior meniscus of both eyelids with a microglass pipette and stored at −80°C until analysis. NMR spectra were acquired using a standard one-dimensional pulse sequence with water…
Benign and Atypical Meningioma Metabolic Signatures by High-Resolution Magic-Angle Spinning Molecular Profiling
2008
Meningiomas are neoplasms that arise from the leptomeningeal covering of the brain and spinal cord, accounting for 15%-20% of CNS tumors. The WHO classifies meningiomas into three histological grades: benign, atypical, and anaplasic in accordance with the clinical prognosis. Atypical and anaplasic meningiomas tend to recur. Sometimes, meningiomas with histological diagnosis of benign meningioma show clinical characteristics of atypical meningioma. In this context, high-resolution magic-angle spinning (HR-MAS) spectroscopy of intact tissue from brain tumor biopsies has shown great potential as a support diagnostic tool. In this work, we show differences between benign and atypical meningioma…
Electrical impedance spectroscopy as a potential adjunct diagnostic tool for cutaneous melanoma.
2012
Background Previous studies have shown statistically significant differences in electrical impedance between various cutaneous lesions. Electrical impedance spectroscopy (EIS) may therefore be able to aid clinicians in differentiating between benign and malignant skin lesions. Objectives The aim of the study was to develop a classification algorithm to distinguish between melanoma and benign lesions of the skin with a sensitivity of at least 98% and a specificity approximately 20 per cent higher than the diagnostic accuracy of dermatologists. Patients/Methods A total of 1300 lesions were collected in a multicentre, prospective, non-randomized clinical trial from 19 centres around Europe. Al…
Clinical performance of the Nevisense system in cutaneous melanoma detection: an international, multicentre, prospective and blinded clinical trial o…
2014
Summary Background Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. Objectives To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. Methods This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were exami…
Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.
2007
A segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thala…
Ex vivo high resolution magic angle spinning metabolic profiles describe intratumoral histopathological tissue properties in adult human gliomas.
2010
In gliomas one can observe distinct histopathological tissue properties, such as viable tumor cells, necrotic tissue or regions where the tumor infiltrates normal brain. A first screening between the different intratumoral histopathological tissue properties would greatly assist in correctly diagnosing and prognosing gliomas. The potential of ex vivo high resolution magic angle spinning spectroscopy in characterizing these properties is analyzed and the biochemical differences between necrosis, high cellularity and border tumor regions in adult human gliomas are investigated. Statistical studies applied on sets of metabolite concentrations and metabolite ratios extracted from 52 high resolu…