Analogical reasoning and aging: the processing speed and inhibition hypothesis.

2014

This study was designed to investigate the effect of aging on analogical reasoning by manipulating the strength of semantic association (LowAssoc or HighAssoc) and the number of distracters' semantic analogies of the A:B::C:D type and to determine which factors might be responsible for the age-related differences on analogical reasoning by testing two different theoretical frameworks: the inhibition hypothesis and the speed mediation hypothesis. We compared young adults and two groups of aging people (old and old-old) with word analogies of the A:B::C:D format. Results indicate an age-related effect on analogical reasoning, this effect being greatest with LowAssoc analogies. It was not asso…

Analogical reasoningAdultMaleMediation (statistics)AgingInjury controlAccident preventionAnalogyPoison controlWord Association TestsExperimental and Cognitive PsychologySemantic associationDevelopmental psychologyYoung AdultReaction TimeHumansProblem SolvingAgedAged 80 and overMiddle AgedSemanticsPsychiatry and Mental healthNeuropsychology and Physiological PsychologyFemaleGeriatrics and GerontologyPsychologyPsychomotor PerformanceCognitive psychologyNeuropsychology, development, and cognition. Section B, Aging, neuropsychology and cognition
researchProduct

Démarche statistique pour la sélection des indicateurs par Random Forests pour la surveillance de la qualité des sols

2013

The volume of data, and the large number of biological variables to be tested (one hundred), require analytical techniques, such asRandom Forests, which can overcome the problem of multi-colinearity for the selection of indicators, sensitive to various factors.Random Forests methodology is appropriate for the selection of the most discriminant variables. So, we searched for the best wayto select them, by bringing together all biological variables, representing the Microflora and Fauna. This approach focuses on impactindicators from the Bio2 program, indicators of flora and indicators of accumulation (snails) were not included.This work has been implemented on the three factors of discrimina…

Analyse discriminanteRandom Forestscontaminantes orgánicosindicateurs pédologiquesland use.organic pollutantspolluants organiques[ SHS.ENVIR ] Humanities and Social Sciences/Environmental studies[ SHS.GEO ] Humanities and Social Sciences/Geography[SHS]Humanities and Social Sciencesbioindicateurs[ SHS ] Humanities and Social Sciencesoccupation des sols.sélectionméthodes statiquesbioindicadoresRandom Forets[ SHS.STAT ] Humanities and Social Sciences/Methods and statisticsComputingMilieux_MISCELLANEOUS[SHS.STAT]Humanities and Social Sciences/Methods and statisticspédologieuso del sueloDiscriminant Analysis[SHS.GEO]Humanities and Social Sciences/Geographysols[SDE.ES]Environmental Sciences/Environmental and Societymetal contaminationETMselección[SHS.ENVIR]Humanities and Social Sciences/Environmental studiesbioindicatorsanálisis discriminante[SDE.ES] Environmental Sciences/Environmental and Society[ SDE.ES ] Environmental Sciences/Environmental and Societyqualité des sols
researchProduct

Statistical methods for the comparison of measurements derived from orthodontic imaging

2000

Biometric comparison procedures for dental imaging methods with continuous outcome were reviewed, mainly concentrating on assessment and comparison of accuracy and precision according to the study design. Univariate graphical and numerical representations of corresponding deviations were summarized to derive a 'check list' of minimum information necessary to compare the measurement methods. The methods reviewed in this investigation are illustrated by the comparison of conventional (radiographic) cephalometry versus assessment using the DigiGraph in 50 female children. A paired t-test and the corresponding confidence interval approach were used to assess deviations in location of two imagin…

Analysis of VariancePaired DataAccuracy and precisionMeasure (data warehouse)BiometryModels StatisticalBiometricsCephalometryComputer scienceUnivariateReproducibility of ResultsOrthodonticsOrthodontics CorrectiveConfidence intervalRadiographic Image EnhancementData Interpretation StatisticalCephalometryStatisticsConfidence IntervalsMedical imagingHumansFemaleChildAlgorithmsSoftwareThe European Journal of Orthodontics
researchProduct

Error estimation and reduction with cross correlations

2010

Besides the well-known effect of autocorrelations in time series of Monte Carlo simulation data resulting from the underlying Markov process, using the same data pool for computing various estimates entails additional cross correlations. This effect, if not properly taken into account, leads to systematically wrong error estimates for combined quantities. Using a straightforward recipe of data analysis employing the jackknife or similar resampling techniques, such problems can be avoided. In addition, a covariance analysis allows for the formulation of optimal estimators with often significantly reduced variance as compared to more conventional averages.

Analysis of covarianceStatistical Mechanics (cond-mat.stat-mech)Monte Carlo methodHigh Energy Physics - Lattice (hep-lat)EstimatorFOS: Physical sciencesMarkov chain Monte CarloHybrid Monte Carlosymbols.namesakeHigh Energy Physics - LatticeResamplingStatisticssymbolsJackknife resamplingCondensed Matter - Statistical MechanicsMathematicsMonte Carlo molecular modeling
researchProduct

Investigating the level of significance of the coherence function in cardiovascular variability analysis

2002

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…

Analysis of covarianceThreshold limit valueFrequency domainStatistical significanceStatisticsSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaEstimatorCoherence (signal processing)Cardiology and Cardiovascular MedicineTransfer functionSoftwareMathematicsSurrogate data
researchProduct

Principal component analysis for the selection of variables in the application of the H-point and generalised H-point standard addition method

2000

The present paper deals with the selection of variables for the H-point and generalised H-point standard additions methods (HPSAM and GHPSAM, respectively). Both methods are applied for the resolution of spectroscopic interfered signals in the UV-vis range. The HPSAM is a suitable method for the resolution of binary and ternary mixtures when the interferent is known. The GHPSAM is applied for the resolution of samples that contain unknown interferents. In this paper, a method based on the study of a principal components analysis (PCA) for the selection of variables for the HPSAM and GHPSAM is proposed. The PCA results show the isolation of the analyte signal from the sample signal, achieved…

AnalyteChemistryStandard additionPrincipal component analysisStatisticsRange (statistics)A priori and a posterioriBinary numberBiological systemTernary operationSelection (genetic algorithm)Analytical ChemistryTalanta
researchProduct

Simultaneous spectrophotometric determination of calcium and magnesium in mineral waters by means of multivariate partial least-squares regression.

1997

A method for simultaneous spectrophotometric determination of calcium and magnesium in mineral waters using multivariate calibration methods is proposed. The method is based on the development of the reaction between the analytes and Methylthymol Blue at pH 11. Two operational modes were used: static (spectral information) and flow injection (FI) (spectral and kinetic information). The selection of variables was studied. A series of synthetic solutions containing different concentrations of calcium and magnesium were used to check the prediction ability of the partial least-squares models. The method was applied to the analysis of mineral waters and the results were compared with those obta…

AnalyteMultivariate statisticsAnalytical chemistrychemistry.chemical_elementCalciumBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundSpectrophotometryPartial least squares regressionElectrochemistrymedicineEnvironmental ChemistryMagnesiumLeast-Squares AnalysisSpectroscopyMineralmedicine.diagnostic_testMagnesiumchemistrySpectrophotometryMultivariate AnalysisCalciumMineral WatersTriarylmethane dyeThe Analyst
researchProduct

Optimisation of chromatographic resolution using objective functions including both time and spectral information.

2014

The optimisation of the resolution in high-performance liquid chromatography is traditionally performed attending only to the time information. However, even in the optimal conditions, some peak pairs may remain unresolved. Such incomplete resolution can be still accomplished by deconvolution, which can be carried out with more guarantees of success by including spectral information. In this work, two-way chromatographic objective functions (COFs) that incorporate both time and spectral information were tested, based on the peak purity (analyte peak fraction free of overlapping) and the multivariate selectivity (figure of merit derived from the net analyte signal) concepts. These COFs are s…

AnalyteMultivariate statisticsChromatographyChromatographyAcetonitrilesTime FactorsResolution (mass spectrometry)ChemistryOrganic ChemistryOrthographic projectionWaterGeneral MedicineBiochemistrySignalChemistry Techniques AnalyticalAnalytical ChemistryPhenolsAlternating least squaresFigure of meritDeconvolutionJournal of chromatography. A
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

More about sampling and estimation of mercaptans in air samples

2013

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

AnalyteSorbentAir samplesAlkaliesHigh-performance liquid chromatographyAnalytical ChemistryCartridgeO-Phthalaldehydechemistry.chemical_compoundMercaptansQUIMICA ANALITICAHumansSulfhydryl CompoundsIsoleucineDerivatizationAir sampling systemFluorescent DyesAir PollutantsChromatographyAirSampling (statistics)DerivatizationSolutionsSpectrometry FluorescencechemistryReagentCalibrationHPLCo-PhthalaldehydeChromatography Liquid
researchProduct