Search results for "STED"
showing 10 items of 2256 documents
Optical properties of ZnO deposited by atomic layer deposition (ALD) on Si nanowires
2018
International audience; In this work, we report proof-of-concept results on the synthesis of Si core/ ZnO shell nanowires (SiNWs/ZnO) by combining nanosphere lithography (NSL), metal assisted chemical etching (MACE) and atomic layer deposition (ALD). The structural properties of the SiNWs/ZnO nanostructures prepared were investigated by X-ray diffraction, Raman spectroscopy, scanning and transmission electron microscopies. The X-ray diffraction analysis revealed that all samples have a hexagonal wurtzite structure. The grain sizes are found to be in the range of 7-14 nm. The optical properties of the samples were investigated using reflectance and photoluminescence spectroscopy. The study o…
Morphological and optical property study of Li doped ZnO produced by microwave-assisted solvothermal synthesis
2021
Abstract ZnO materials have been at the centre of many studies for decades. Doping of ZnO by lithium atoms is a prospective approach for compensation of n-type conductivity in the unintentionally doped ZnO aimed at obtaining p-type semiconductor. In this study, we have synthesized ZnO rod-like powders doped with lithium ions (0–0.65 atom%) by the new microwave-assisted solvothermal method in order to obtain greater photoluminescence intensity of ZnO emissions in the UV region. The obtained powders contain nanoparticles from 20 nm up to 250 nm depending on Li content. X-ray diffractometry and Raman spectroscopy were employed to characterise the structure of ZnO powders, scanning electron mic…
Megakaryocytic features useful for the diagnosis of myeloproliferative disorders can be obtained by a novel unsupervised software analysis
2006
An unsupervised method for megakaryocyte detection and analysis is proposed, in order to validate supplementary tools which can be of help in supporting the pathologist in the classification of Philadelphia negative chronic myeloproliferative disorders with thrombocytosis. The experiment was conducted on high power magnification photomicrographs taken from hematoxylin-and-eosin 3 µm thick sections of formalin fixed, paraffin embedded bone marrow biopsies from patients with reactive thrombocytosis or chronic myeloproliferative disorders. Each megakaryocyte has been isolated in the photos through an image segmentation process, mainly based on mathematical morphology and wavelet analysis. A se…
Wearable, Fiber-less, Multi-Channel System for Continuous Wave Functional Near Infrared Spectroscopy Based on Silicon Photomultipliers Detectors and …
2019
Development and in-vivo validation of a Continuous Wave (CW) functional Near Infrared Spectroscopy (fNIRS) system is presented. The system is wearable, fiber-less, multi-channel (16×16, 256 channels) and expandable and it relies on silicon photomultipliers (SiPMs) for light detection. SiPMs are inexpensive, low voltage and resilient semiconductor light detectors, whose performances are analogous to photomultiplier tubes (PMTs). The advantage of SiPMs with respect to PMTs is that they allow direct contact with the scalp and avoidance of optical fibers. In fact, the coupling of SiPMs and light emitting diodes (LEDs) allows the transfer of the analog signals to and from the scalp through thin …
Theory of quantum-circuit refrigeration by photon-assisted electron tunneling
2017
We focus on a recently experimentally realized scenario of normal-metal-insulator-superconductor tunnel junctions coupled to a superconducting resonator. We develop a first-principles theory to describe the effect of photon-assisted electron tunneling on the quantum state of the resonator. Our results are in very good quantitative agreement with the previous experiments on refrigeration and heating of the resonator using the photon-assisted tunneling, thus providing a stringent verification of the developed theory. Importantly, our results provide simple analytical estimates of the voltage-tunable coupling strength and temperature of the thermal reservoir formed by the photon-assisted tunne…
Nonlinear photon-assisted tunneling transport in optical gap antennas.
2014
International audience; We introduce strongly coupled optical gap antennas to interface optical radiation with current-carrying electrons at the nanoscale. The transducer relies on the nonlinear optical and electrical properties of an optical gap antenna operating in the tunneling regime. We discuss the underlying physical mechanisms controlling the conversion involving d-band electrons and demonstrate that a simple two-wire optical antenna can provide advanced optoelectronic functionalities beyond tailoring the electromagnetic response of a single emitter. Interfacing an electronic command layer with a nanoscale optical device may thus be facilitated by the optical rectennas discussed here.
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.
2014
Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…
Phantom size in brachytherapy source dosimetric studies
2004
An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…
Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events
2014
The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low su…