Search results for "STED"

showing 10 items of 2256 documents

Preliminary study of the Craniofacial Pain and Disability Inventory-11:validation for patients with head and neck cancer

2021

Background Cancer involves numerous physical, psychological and emotional changes and has a negative impact on patients. Although there are a wide variety of questionnaires for general use in patients with cancer, very few are available that assess the pain, disability and craniomandibular functionality of patients with head and neck cancer (HNC) in a more specific manner. The purpose of this study is to present the preliminary behavior of the CF-PDI in its reduced version adapted for patients with HNC. Material and Methods A total of 61 patients with HNC were included in a study to preliminarily analyze the internal consistency of the instrument, the convergent validity and the floor and c…

medicine.medical_specialtyPsychometricscone-beam computed tomographyMasseter muscleCronbach's alphaQuality of lifeFacial PainRating scaleOral Cancer and Potentially malignant disordersSurveys and QuestionnairesThreshold of painimpactedHumansMedicinetoothGeneral DentistryUNESCO:CIENCIAS MÉDICASPain Measurementbusiness.industryResearchHead and neck cancerReproducibility of Resultsbone densitymedicine.diseasehumanitiesimage processingOtorhinolaryngologyConvergent validityHead and Neck Neoplasmscomputer-assistedQuality of LifePhysical therapymaxillaSurgeryPain catastrophizingbusiness
researchProduct

Quantitative magnetic resonance imaging for focal liver lesions: bridging the gap between research and clinical practice

2021

Magnetic resonance imaging (MRI) is highly important for the detection, characterization, and follow-up of focal liver lesions. Several quantitative MRI-based methods have been proposed in addition to qualitative imaging interpretation to improve the diagnostic work-up and prognostics in patients with focal liver lesions. This includes DWI with apparent diffusion coefficient measurements, intravoxel incoherent motion, perfusion imaging, MR elastography, and radiomics. Multiple research studies have reported promising results with quantitative MRI methods in various clinical settings. Nevertheless, applications in everyday clinical practice are limited. This review describes the basic princ…

medicine.medical_specialtyQuantitative magnetic resonance imagingContrast MediaPerfusion scanningReview Article030218 nuclear medicine & medical imaging03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingIn patientIntravoxel incoherent motionRadiomicsmedicine.diagnostic_testbusiness.industryLiver NeoplasmsMagnetic resonance imagingGeneral MedicinePerfusion imagingImage EnhancementPrognosisMagnetic Resonance ImagingClinical PracticeDiffusion Magnetic Resonance Imaging030220 oncology & carcinogenesisElasticity Imaging TechniquesDiffusion-weighted imagingRadiologyElastographyElastographySettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessThe British Journal of Radiology
researchProduct

D2-receptor imaging with [123I]IBZM and Single Photon Emission Tomography in psychiatry: a survey of current status

1995

D2-dopamine receptors can be visualized in the human brain in vivo by Single Photon Emission Tomography (SPECT) and the radiolabeled benzamide [123I]IBZM. The present paper reviews the current status of this type of functional brain imaging with respect to basic methodological aspects, data analysis and quantification. The results from published clinical studies in different psychiatric patient populations and normal controls with [123I]IBZM are reviewed. [123I]IBZM-SPECT is a powerful tool for the investigation of D2-dopamine receptor status in psychiatric disorders, different types of drug treatment as well as therapeutic and side effects of pharmacologic agents. However, there still is a…

medicine.medical_specialtyReceptor StatusPyrrolidinesNeurologyContrast MediaDrug treatmentDopamine receptor D2Image Processing Computer-AssistedmedicineSingle Photon Emission TomographyHumansPsychiatryBiological PsychiatryBrain ChemistryTomography Emission-Computed Single-Photonmedicine.diagnostic_testReceptors Dopamine D2business.industryBrainHuman brainPsychiatry and Mental healthmedicine.anatomical_structureNeurology123i ibzmPositron emission tomographyBenzamidesDopamine AntagonistsNeurology (clinical)Nuclear medicinebusinessPsychologyJournal of Neural Transmission
researchProduct

Soluble ligands and their receptors in human embryo development and implantation.

2014

Extensive evidence suggests that soluble ligands and their receptors mediate human preimplantation embryo development and implantation. Progress in this complex area has been ongoing since the 1980s, with an ever-increasing list of candidates. This article specifically reviews evidence of soluble ligands and their receptors in the human preimplantation stage embryo and female reproductive tract. The focus will be on candidates produced by the human preimplantation embryo and those eliciting developmental responses in vitro, as well as endometrial factors related to implantation and receptivity. Pathways to clinical translation, including innovative diagnostics and other technologies, are al…

medicine.medical_specialtyReproductive Techniques AssistedEndocrinology Diabetes and Metabolismmedicine.medical_treatmentReproductive medicineEmbryonic DevelopmentReceptors Cell SurfaceBiologyEndometriumBioinformaticsLigandsHuman chorionic gonadotropinEmbryo Culture TechniquesEndometriumEndocrinologyPregnancymedicineHumansReceptors Growth FactorBlastocystEmbryo ImplantationReceptors CytokineReceptorGrowth SubstancesFallopian TubesIn vitro fertilisationEmbryoCoculture TechniquesHormonesCulture MediaMicroRNAsmedicine.anatomical_structureBlastocystImmunologyCytokinesFemaleEmbryo qualityEndocrine reviews
researchProduct

Rate of Post-Operative Pancreatic Fistula after Robotic-Assisted Pancreaticoduodenectomy with Pancreato-Jejunostomy versus Pancreato-Gastrostomy: A R…

2021

Background: Different techniques of pancreatic anastomosis have been described, with inconclusive results in terms of pancreatic fistula reduction. Studies comparing robotic pancreaticogastrostomy (PG) and pancreaticojejunostomy (PJ) are scarcely reported. Methods: The present study analyzes the outcomes of two case-matched groups of patients who underwent PG (n = 20) or PJ (n = 40) after pancreaticoduodenectomy. The primary aim was to compare the rate of post-operative pancreatic fistula. Results: Operative time (375 vs. 315 min, p = 0.34), estimated blood loss (270 vs. 295 mL, p = 0.44), and rate of clinically relevant post-operative pancreatic fistula (12.5% vs. 10%, p = 0.82) were simil…

medicine.medical_specialtyRobotic assistedmedicine.medical_treatmentAnastomosisArticlerobotic pancreatic surgery03 medical and health sciences0302 clinical medicinepancreatic fistulaBlood lossMedicinePost operativebusiness.industryRGeneral MedicinePancreaticoduodenectomymedicine.diseaseGastrostomySurgeryPancreatic fistulapancreato-gastrostomy030220 oncology & carcinogenesisJejunostomyMedicine030211 gastroenterology & hepatologybusinessJournal of Clinical Medicine
researchProduct

Tangential Venous Resections during Robotic-Assisted Pancreaticoduodenectomy: the Results of a Case Series (with Video)

2020

Introduction: Despite the potential advantages in terms of microdissection and microsuturing capabilites, the robotic approach for borderline resectable pancreatic cancer is scarcely reported. Methods: We report our technique for a robotic-assisted pancreaticoduodenectomy with tangential Portal/ Superior Mesenteric Vein resection/reconstruction (RPD PV/SMV).We also compared the surgical outcomes of eight consecutive patients undergoing RPD PV/SMV with that of sixty patients who underwent robotic-assisted pancreaticoduodenectomy (RPD) in the same period of time. Results: A total of eight consecutive patients underwent RPD PV/SMV. We observed an increased estimated blood loss (550 vs 280 mL, …

medicine.medical_specialtyRobotic assistedmedicine.medical_treatmentPancreaticoduodenectomyResection03 medical and health sciencesMesenteric VeinsPancreatectomy0302 clinical medicineRobotic Surgical ProceduresBlood lossBorderline resectablemedicineHumansSuperior mesenteric veinRetrospective StudiesPortal Veinbusiness.industryGastroenterologyPancreaticoduodenectomyVascular resectionSurgeryPancreatic NeoplasmsVideo techniqueTreatment Outcome030220 oncology & carcinogenesisOperative time030211 gastroenterology & hepatologySurgeryRobotic-assisted pancreaticoduodenectomybusinessHospital stay
researchProduct

Effect of Computer-Aided Navigation Techniques on the Accuracy of Endodontic Access Cavities: A Systematic Review and Meta-Analysis

2021

Simple Summary The endodontic access cavity is an essential step in the root canal treatment allowing the access and location of the root canal system. The inaccuracy during the endodontic access cavitie can lead to intraoperative complications such as missed root canals or root perforations, and hence affect the prognosis of the root canal treatment. The development of computer-aided static and dynamic navigation techniques has improved the accuracy of endodontic access cavities and root canal location; however, it is necessary a comparative analysis to clarify which of the computer-aided navigation system is more accurate. This systematic review and meta-analysis aims to clarify the root …

medicine.medical_specialtyRoot canalDentistryReviewBiologyGeneral Biochemistry Genetics and Molecular Biologyendodontic access cavity03 medical and health sciences0302 clinical medicineQualitative analysis0502 economics and businessmedicinelcsh:QH301-705.5real-time trackingGeneral Immunology and Microbiologybusiness.industry05 social sciencesNavigation systemPrediction interval030206 dentistryEndodonticscomputer-assisted treatmentimage-guided treatmentendodonticsSystematic reviewmedicine.anatomical_structurelcsh:Biology (General)Meta-analysisComputer-aidednavigation system050211 marketingGeneral Agricultural and Biological SciencesbusinessBiology
researchProduct

Cost-effectiveness of sofosbuvir plus ribavirin with or without pegylated interferon for the treatment of chronic hepatitis C in Italy.

2015

Objective:Across Italy up to 7.3% of the population is infected with hepatitis C virus (HCV), with long-term complications resulting in high medical costs and significant morbidity and mortality. Current treatment options have limitations due to side effects, interferon intolerability and ineligibility, long treatment durations and low sustained virological response (SVR) rates, especially for the most severe patients). Sofosbuvir is the first nucleotide polymerase inhibitor with pan-genotypic activity. Sofosbuvir, administered with ribavirin (RBV) and with or without pegylated interferon (PEG-INF), resulted in >90% SVR across treatment-naïve (TN) genotype (GT) 1-6 patients. It is also t…

medicine.medical_specialtySofosbuvirGenotypeCost effectivenessHepatitis C virusCost-Benefit AnalysisAlpha interferonmedicine.disease_causeGastroenterologyPolyethylene GlycolAntiviral AgentsSeverity of Illness IndexTelaprevirTelaprevirPolyethylene Glycolschemistry.chemical_compoundPegylated interferonBoceprevirInternal medicineQuality-Adjusted Life YearRibavirinmedicineCost-effectiveness analysiHumansCost-Benefit AnalysiAntiviral AgentBoceprevirbusiness.industryHealth PolicyRibavirinInterferon-alphaMarkov ChainHepatitis C ChronicPatient Acceptance of Health CareVirologyChronic hepatitis C infectionMarkov ChainschemistryItalyDrug Therapy CombinationQuality-Adjusted Life YearsSofosbuvirbusinessmedicine.drugHumanJournal of medical economics
researchProduct

Causal analysis of short-term cardiovascular variability: state-dependent contribution of feedback and feedforward mechanisms.

2016

Baroreflex function is usually assessed from spontaneous oscillations of blood pressure (BP) and cardiac RR interval assuming a unidirectional influence from BP to RR. However, the interaction of BP and RR is bidirectional—RR also influences BP. Novel methods based on the concept of Granger causality were recently developed for separate analysis of feedback (baroreflex) and feedforward (mechanical) interactions between RR and BP. We aimed at assessing the proportion of the two causal directions of the interactions between RR and systolic BP (SBP) oscillations during various conditions, and at comparing causality measures from SBP to RR with baroreflex gain indexes. Arterial BP and ECG sig…

medicine.medical_specialtySupine position0206 medical engineeringBiomedical EngineeringBlood Pressure02 engineering and technologyBaroreflex03 medical and health sciencesElectrocardiographyYoung Adult0302 clinical medicineInternal medicineHeart ratemedicineSupine PositionHumanscardiovascular diseasesSimulationFeedback PhysiologicalHead-up tiltFeed forwardComputer Science Applications1707 Computer Vision and Pattern RecognitionSignal Processing Computer-AssistedBaroreflex020601 biomedical engineeringCausalityComputer Science ApplicationsTerm (time)Blood pressureMental arithmeticState dependentSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaGranger causalityCardiologyInformation domainPsychology030217 neurology & neurosurgeryStress Psychologicalcirculatory and respiratory physiologyMedicalbiological engineeringcomputing
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct