Search results for "STING"
showing 10 items of 3756 documents
Harvesting rainfall energy by means of piezoelectric transducer
2013
In this paper a detailed study on the piezoelectric energy harvesting of rainfall is presented. Different features have been taken into account in order to define the limits in this energy harvesting. Only commercial transducers have been considered: a lead zirconate titanate and polyvinylidene difluoride transducer.
Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel
2017
Background Titanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions. Material and Methods Seventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statis…
Effect of alloy type and casting technique on the fracture strength of implant-cemented structures.
2010
Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR…
Outgrowth endothelial cells isolated and expanded from human peripheral blood progenitor cells as a potential source of autologous cells for endothel…
2006
One challenge of particular importance in tissue engineering is to improve vascularization of larger size defects, which would then facilitate a sufficient supply with oxygen and nutrients to the central regions of a larger tissue-engineered construct or in highly vascularized tissues. In this study, we show that outgrowth endothelial cells (OECs) derived from human peripheral blood can serve as a source of human autologous endothelial cells and can be used in combination with fibroin silk fiber meshes for applications in tissue engineering. OEC reveal a highly differentiated endothelial phenotype as well as a high phenotypic stability during their expansion. Furthermore, OEC showed very pr…
Tissue-like self-assembly in cocultures of endothelial cells and osteoblasts and the formation of microcapillary-like structures on three-dimensional…
2007
The survival and functioning of a bone biomaterial requires a rapid and stable vascularization after implantation. However, the mechanisms involved in the context of the complex healing microenvironment are poorly understood. To evaluate the vascularization potential of bone biomaterials, angiogenic stimuli were added to human dermal microvascular endothelial cells (HDMEC) growing on three-dimensional (3-D) bone biomaterials consisting of porous hydroxyapatite, porous calcium phosphate, porous nickel-titanium, successfully being used in humans, and also silk fibroin nets. HDMEC did not migrate to form microcapillary-like structures as they did on cell culture plastic. In cocultures of HDMEC…
Endothelialization of a non-woven silk fibroin net for use in tissue engineering: growth and gene regulation of human endothelial cells
2004
Abstract We have previously shown that a biomaterial consisting of a non-woven fibroin net produced from silk (Bombyx mori) cocoons is an excellent scaffolding material for a wide variety of human cells of different tissue types. Endothelialization must take place for a biomaterial to be successful after implantation. Therefore, primary human endothelial cells and the human endothelial cell lines, HPMEC-ST1.6R and ISO-HAS-1, were examined for adherence and growth patterns on the fibroin nets by confocal laser scanning microscopy after vital staining of the cells and by electron microscopy. Endothelial cells adhered and spread along individual fibers of the nets and did not fill the gaps bet…
Fibronectin-mediated endothelialisation of chitosan porous matrices.
2009
Chitosan (Ch) porous matrices were investigated regarding their ability to be colonized by human microvascular endothelial cells (HPMEC-ST1.6R cell line) and macrovascular endothelial cells namely HUVECs. Specifically we assessed if previous incubation of Ch in a fibronectin (FN) solution was effective in promoting endothelial cell (EC) adhesion to Ch matrices with different degrees of acetylation (DAs). Upon FN physiadsorption, marked differences were found between the two DAs investigated, namely DA 4% and 15%. While cell adhesion was impaired on Ch with DA 15%, ECs were able to not only adhere to Ch with DA 4%, but also to spread and colonize the scaffolds, with retention of the EC pheno…
Vascularization and gene regulation of human endothelial cells growing on porous polyethersulfone (PES) hollow fiber membranes.
2004
Abstract Open-cell hollow fibers made of polyethersulfone (PES) manufactured in the absence of solvents with pore diameters smaller than 100 μm were examined for vascularization by human endothelial cells. The goal of this study was to determine whether the 3-D porous character of the PES surface affected human endothelial cell morphology and functions. Freshly isolated human endothelial cells from the skin (HDMEC), from the lung (HPMEC) and from umbilical cords (HUVEC) and two human endothelial cell lines, HPMEC-ST1.6R and ISO-HAS.c1 were added to PES fibers and cell adherence and growth was followed by confocal laser scanning microscopy. Prior coating of PES with gelatin or fibronectin wa…
Mesenchymal stem cell proliferation and differentiation on load-bearing trabecular Nitinol scaffolds.
2013
Bone tissue regeneration in load-bearing regions of the body requires high-strength porous scaffolds capable of supporting angiogenesis and osteogenesis. 70% porous Nitinol (NiTi) scaffolds with a regular 3-D architecture resembling trabecular bone were produced from Ni foams using an original reactive vapor infiltration technique. The "trabecular Nitinol" scaffolds possessed a high compressive strength of 79 MPa and high permeability of 6.9×10(-6) cm2. The scaffolds were further modified to produce a near Ni-free surface layer and evaluated in terms of Ni ion release and human mesenchymal stem cell (hMSC) proliferation (AlamarBlue), differentiation (alkaline phosphatase activity, ALP) and …
Tuning of the Mg Alloy AZ31 Anodizing Process for Biodegradable Implants
2021
Coatings were grown on the AZ31 Mg alloy by a hard anodizing process in the hot glycerol phosphate-containing electrolyte. Anodizing conditions were optimized, maximizing corrosion resistance estimated by impedance measurements carried out in Hank's solution at 37 °C. A post anodizing annealing treatment (350 °C for 24 h) allowed us to further enhance the corrosion resistance of the coatings mainly containing magnesium phosphate according to energy-dispersive X-ray spectroscopy and Raman analyses. Gravimetric measurements revealed a hydrogen evolution rate within the limits acceptable for application of AZ31 in biomedical devices. In vitro tests demonstrated that the coatings are biocompati…