Search results for "Scanning"

showing 10 items of 1808 documents

Histological and ultrastructural study of corneal tunnel incisions using diamond and steel keratomes

1998

Abstract Purpose: To study the morphology of corneal tunnel incisions using diamond and steel keratomes. Setting: Department of Ophthalmology, University of Giessen, Germany. Methods: Corneal tunnel incisions were performed in six human cadaver eyes using three types of diamond keratomes and a steel keratome. The incision profile and morphology were evaluated and compared using light and scanning electron microscopy. Results: The steel keratome caused more disruption of corneal stromal tissue, while the diamond keratomes produced a more regular, smoother incision. The dissecting incision resulted in a smoother surface of cut stromal tissue than the stab incision. Conclusions: The high quali…

Human cadaverWound HealingMaterials scienceDiamondCataract ExtractionAnatomyengineering.materialSensory SystemsCorneabody regionsOphthalmologymedicine.anatomical_structureCadaverCorneaCadaverMicroscopy Electron ScanningUltrastructuremedicineengineeringHumansSurgerySurgical incisionBiomedical engineeringJournal of Cataract and Refractive Surgery
researchProduct

Inulin-based polymer coated SPIONs as potential drug delivery systems for targeted cancer therapy

2014

This paper deal with the synthesis and characterization of PEGylated squalene-grafted-inulin amphiphile capable of self-assembling and self-organizing into nanocarriers once placed in aqueous media. It was exploited as coating agent for obtaining doxorubicin loaded superparamagnetic iron oxide nanoparticles (SPIONs) endowed with stealth like behavior and excellent physicochemical stability. Inulin was firstly modified in the side chain with primary amine groups, followed in turn by conjugation with squalenoyl derivatives through common amidic coupling agents and PEGylation by imine linkage. Polymer coated SPIONs were so obtained by spontaneous self-assembling of inulin copolymer onto magnet…

Hydrodynamic radiusCell SurvivalPolymersSurface PropertiesPharmaceutical ScienceTherapeutic indexSpectroscopy Fourier Transform InfraredAmphiphileZeta potentialmedicineSPIONs Inulin copolymer Doxorubicin Magnetic targeting Squalene PegylatedHumansOrganic chemistryDoxorubicinParticle SizeMagnetite NanoparticlesDrug CarriersAntibiotics AntineoplasticMolecular StructureChemistryInulinGeneral MedicineHCT116 CellsCombinatorial chemistryDrug LiberationDoxorubicinDrug deliveryMicroscopy Electron ScanningPEGylationNanocarriersBiotechnologymedicine.drugEuropean Journal of Pharmaceutics and Biopharmaceutics
researchProduct

The Parasitic Colonization of the Horny Layer in Tinea Versicolor

1972

Observations of vertical sections and of tape strippings of areas infested with tinea versicolor indicate that because of their dimorphic state, these parasites can colonize the horny layer. Mycelial hyphae progress downwards into the intercellular spaces of the horny cells where they feed on nonkeratinous substances and extrude proliferating yeast cells which form clusters in nest-like cavities. The yeast-mycelial conversion gives rise to new mycelial hyphae and the cycle is complete. The parasites are actually lodged in tunnels and nests hollowed out in the horny layer. A dynamic balance between the cycle of the parasites and the renewal rate of the horny layer is responsible for the long…

HyphaHorny layerfungiCell BiologyDermatologyBiologymedicine.diseaseBiochemistryTinea versicolorMicrobiologyBotanyTinea VersicolormedicineMicroscopy Electron ScanningHumansColonizationMitosporic FungiShort durationMolecular BiologyMyceliumSkinJournal of Investigative Dermatology
researchProduct

Protective effect of mesoporous silica particles on encapsulated folates.

2016

Mesoporous silica particles (MSPs) are considered suitable supports to design gated materials for the encapsulation of bioactive molecules. Folates are essential micronutrients which are sensitive to external agents that provoke nutritional deficiencies. Folates encapsulation in MSPs to prevent degradation and to allow their controlled delivery is a promising strategy. Nevertheless, no information exists about the protective effect of MSPs encapsulation to prevent their degradation. In this work, 5-formyltetrahydrofolate (FO) and folic acid (FA) were entrapped in MSPs functionalized with polyamines, which acted as pH-dependent molecular gates. The stability of free and entrapped vitamins af…

INGENIERIA DE LA CONSTRUCCIONFolic acidTECNOLOGIA DE ALIMENTOSLightSilicon dioxideBioactive moleculesPharmaceutical Science02 engineering and technology010402 general chemistry01 natural sciencesMesoporous silica particleschemistry.chemical_compoundFolic AcidMicroscopy Electron TransmissionControlled deliveryControlled releasechemistry.chemical_classificationChromatographyBiomoleculeQUIMICA INORGANICATemperatureGeneral Medicine5-FormyltetrahydrofolateMesoporous silicaHydrogen-Ion Concentration021001 nanoscience & nanotechnologySilicon DioxideControlled release0104 chemical sciencesBioavailabilitychemistryFolic acidChemical engineeringMicroscopy Electron ScanningEncapsulation0210 nano-technologyStabilityPorosityPowder DiffractionBiotechnologyEuropean journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V
researchProduct

Microradiography and confocal laser scanning microscopy applied to enamel lesions formed in vivo with and without fluoride varnish treatment

1996

The aim of the present investigation was to combine 2 techniques suitable for lesion characterization: quantitative microradiography (TMR) and confocal laser scanning microscopy (CLSM) on in vivo induced lesions with and without a fluoride varnish (Duraphat(R)) treatment. Orthodontic bands were attached to premolars to be extracted for orthodontic reasons to induce enamel caries on the buccal surfaces. In the caries development part of the study, 1 tooth of each pair received at the start 1 topical application with the fluoride varnish Duraphat(R), the contralateral tooth serving as untreated control. All teeth were extracted after 4 weeks. In the caries progression part, the premolars were…

INVIVODentistrymicroradiographychemistry.chemical_compoundPaintPremolarChemical PrecipitationScattering RadiationFluorides TopicalChildTooth DemineralizationOrthodonticsMineralsconfocal laser scanning microscopyMicroscopy ConfocalSOUNDEnamel paintCARIESdemineralizationDURAPHATmedicine.anatomical_structureLIGHTvisual_artvisual_art.visual_art_mediumDisease Progressionmedicine.symptomcarious lesionFluorideAdolescentConfocalDental CariesLesionOrthodontic Appliancesstomatognathic systemmedicineHumansBicuspidDental EnamelGeneral DentistryINSITUINVITRObusiness.industryFluoride varnishfluoride varnishBuccal administrationDemineralizationstomatognathic diseaseschemistrySodium FluoridebusinessEuropean Journal of Oral Sciences
researchProduct

Depth profiles of aggregate centers and nanodefects in LiF crystals irradiated with 34 MeV 84Kr, 56 MeV 40Ar and 12 MeV 12C ions

2018

I. Manika, J. Maniks and R. Zabels acknowledge the national project IMIS2. A. Dauletbekova, A. Akilbekov, M. Zdorovets and A. Seitbayev acknowledge the GF AP05134257of Ministry of Education and Science the Republic of Kazakhstan.

IONSMaterials sciencePhotoluminescenceF2 AND F3^+ CENTERSDislocationsAGGREGATESFLUORINE COMPOUNDS02 engineering and technologyETCHING7. Clean energy01 natural sciencesFluenceENERGY DISSIPATIONIonIRRADIATION EXPERIMENTSLIF CRYSTALION BOMBARDMENT0103 physical sciencesF2 and F3 + centersMaterials Chemistry:NATURAL SCIENCES:Physics [Research Subject Categories]IrradiationLUMINESCENCE INTENSITYPhotoluminescenceLITHIUM COMPOUNDS010302 applied physicsLiF crystalsNANOHARDNESSDISLOCATIONS (CRYSTALS)Surfaces and InterfacesGeneral ChemistryNanoindentation021001 nanoscience & nanotechnologyCondensed Matter PhysicsIsotropic etchingSurfaces Coatings and FilmsLASER SCANNING CONFOCAL MICROSCOPYNANOINDENTATION TECHNIQUESIon irradiationCOLOR CENTERSHardeningELECTRONIC ENERGY LOSSAtomic physicsDislocationLUMINESCENCE SIGNALS0210 nano-technologyLuminescenceDamage depth profiles
researchProduct

Defect detection in additively manufactured titanium prosthesis by flying laser scanning thermography

2018

Abstract Metal additive manufacturing is nowadays a well-established technology for cutting edge applications in the automotive, aerospace, defense and medical sectors. Since additive metal deposition is basically a welding method, which creates parts by successively adding layers of material, there is a chance for defects like pores, cracks, inclusions and lack of fusion to develop. As a matter of fact, interlayer and intralayer defects are often observed in additive manufactured components. However, if one considers the typical end applications along with the high costs involved in metal additive manufactured components, a “zero defect” target is close to mandatory for this technology. Pl…

IR ThermographyMaterials scienceLaser scanningbusiness.industryAdditive ManufacturingLaser thermographyAutomotive industryTitanium alloyMechanical engineeringWeldingEdge (geometry)Defect Sensitivity01 natural scienceslaw.invention010309 opticsSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchinelawNondestructive testing0103 physical sciencesThermographybusinessAerospace010301 acousticsEarth-Surface ProcessesProcedia Structural Integrity
researchProduct

Exploring the atomic structure of 1.8 nm monolayer-protected gold clusters with aberration-corrected STEM

2017

Abstract Monolayer-protected (MP) Au clusters present attractive quantum systems with a range of potential applications e.g. in catalysis. Knowledge of the atomic structure is needed to obtain a full understanding of their intriguing physical and chemical properties. Here we employed aberration-corrected scanning transmission electron microscopy (ac-STEM), combined with multislice simulations, to make a round-robin investigation of the atomic structure of chemically synthesised clusters with nominal composition Au 144 (SCH 2 CH 2 Ph) 60 provided by two different research groups. The MP Au clusters were “weighed” by the atom counting method, based on their integrated intensities in the high …

Icosahedral symmetrymonolayer-Protected Gold Clusters02 engineering and technology010402 general chemistry01 natural sciencesMolecular physicsatomic structureatom counting methodMonolayerScanning transmission electron microscopyAu144(SR)60ta116InstrumentationQuantumaberration-Corrected STEMRange (particle radiation)ta114Chemistry021001 nanoscience & nanotechnologyDark field microscopyAtomic and Molecular Physics and Optics0104 chemical sciencesElectronic Optical and Magnetic MaterialsAmorphous solidExponentAtomic physics0210 nano-technologyUltramicroscopy
researchProduct

Numerical simulations of photon scanning tunneling microscopy: role of a probe tip geometry in image formation

2005

Abstract Numerical simulations of two-dimensional probe–object system emulating a photon scanning tunnelling microscope are presented. R -matrix propagation algorithm incorporated into the differential method was used to achieve an extended capability to rigorously model a realistic system consisting of both a probe and a sample. Influence of the probe tip parameters on image formation in scanning near-field microscopy has been investigated. Coupling of the near-field to a single-mode probe and formation of a guided fundamental mode in a probe were investigated for various probe widths and lengths. The influence of the probe taper shape and apex size on near-field images was studied for sin…

Image formationScanning Hall probe microscopeMaterials scienceMicroscopebusiness.industryNear-field opticsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionScanning probe microscopyOpticslawMicroscopyNear-field scanning optical microscopeElectrical and Electronic EngineeringPhysical and Theoretical ChemistryScanning tunneling microscopebusinessOptics Communications
researchProduct

Analysis of image formation with a photon scanning tunneling microscope

1996

International audience; The photon scanning tunneling microscope (PSTM) is based on the frustration of a total internal reflected beam by the end of an optical fiber. Until now it has been used to obtain topographic information, generally for smooth samples. We report theoretical as well as experimental results on the observation of a step on a quartz substrate with the PSTM. These results demonstrate the effects on image formation of the distance between the fiber tip and the sample surface, the orientation of the incident beam with respect to the step, the polarization, and the coherence of the light. Good agreement exists between numerical simulations and experiments. We show that a pert…

Image formation[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics]Optical fiberScanning tunneling spectroscopy02 engineering and technology01 natural scienceslaw.invention010309 opticsScanning probe microscopyOpticslaw0103 physical sciencesLight beamPhysicsTotal internal reflection[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryNear-field optics021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsComputer Vision and Pattern RecognitionScanning tunneling microscopebusiness0210 nano-technology
researchProduct