Search results for "Sensitivity and Specificity"
showing 10 items of 1080 documents
Evaluation of a rapid immunochromatographic test for the detection of low burden Dirofilaria immitis (heartworm) in dogs and cats
2017
The performance of a rapid immunochromatographic test for the detection of Dirofilaria immitis antigens (Speed Diro™; BVT-Virbac, France) was assessed in 49 experimentally infected dogs and in 244 naturally infected animals; 142 dogs and 102 cats. In experimentally infected dogs, Speed Diro™ showed a sensitivity of 90.9% in dogs infected with one adult female worm and 100% in dogs infected with more than one female worm. Specificity was 100%. For naturally infected dogs, the Knott test and PetChek® HTWM PF served as reference methods for microfilaremia and antigenemia, respectively. All microfilaemic dogs (55/142) were positive with Speed Diro™. Importantly, none of the 21 dogs infected wit…
Establishment of two quantitative nested qPCR assays targeting the human EPO transgene.
2016
International audience; For ethical and safety reasons it is critical to develop easily implemented assays with high sensitivity and specificity for gene doping surveillance. Two nested quantitative real-time PCR (qPCR) assays were developed that target the human EPO (hEPO) cDNA sequence in a circular form, representative of recombinant adeno-associated viral (rAAV) vector genomes found in vivo. Through an interlaboratory evaluation, the assays were validated and utilized in an in vitro blinded study. These assays are specific and extremely sensitive with a limit of detection (LOD) of 1 copy of circular plasmid DNA and a limit of quantification (LOQ) of 10 to 20 copies in the presence of 50…
Performance evaluation of a newly developed molecular assay for the accurate diagnosis of gastroenteritis associated with norovirus of genogroup II
2018
The performance of a newly proposed fully automated cassette-based sample-to-results solution for norovirus (NoV) detection, InGenius Norovirus ELITe MGB®, was evaluated. A total of 120 selected archival stool samples from children hospitalized for acute gastroenteritis were used to compare the results to a reference real-time RT-PCR. The InGenius NoV assay showed optimal diagnostic accuracy (sensitivity, 100%; specificity, 95.7%) and was able to correctly detect the entire wide panel of epidemiologically relevant genotypes tested. These preliminary results suggest that the InGenius NoV assay can be recommended as a valuable method for accurate diagnosis of NoV GII infection in epidemic and…
Inference of SARS-CoV-2 spike-binding neutralizing antibody titers in sera from hospitalized COVID-19 patients by using commercial enzyme and chemilu…
2021
medRxiv: https://doi.org/10.1101/2020.09.07.20188151
Determinants of the Quality of Warfarin Control after Venous Thromboembolism and Validation of the SAMe-TT2-R2 Score: An Analysis of Hokusai-VTE.
2019
Background Time in therapeutic range (TTR) measures the quality of vitamin K antagonist (VKA) anticoagulation. In patients with atrial fibrillation, the dichotomized SAMe-TT2-R2 score (≥2 vs. < 2 points) can predict if adequate TTR is unlikely to be achieved. Aims We validated the SAMe-TT2-R2 score in patients with venous thromboembolism (VTE) randomized to the warfarin arm of the Hokusai-VTE trial. Patients and Methods A total of 3,874 patients were included in the primary analysis (day 31–180 from randomization). The efficacy and safety outcomes were symptomatic recurrent VTE and major or clinically relevant non-major bleeding. Results The rates of recurrent VTE and bleeding events we…
The diagnosis of chronic endometritis in infertile asymptomatic women: a comparative study of histology, microbial cultures, hysteroscopy, and molecu…
2017
Background Chronic endometritis is a persistent inflammation of the endometrial mucosa caused by bacterial pathogens such as Enterobacteriaceae, Enterococcus, Streptococcus, Staphylococcus, Mycoplasma, and Ureaplasma. Although chronic endometritis can be asymptomatic, it is found in up to 40% of infertile patients and is responsible for repeated implantation failure and recurrent miscarriage. Diagnosis of chronic endometritis is based on hysteroscopy of the uterine cavity, endometrial biopsy with plasma cells being identified histologically, while specific treatment is determined based on microbial culture. However, not all microorganisms implicated are easily or readily culturable needing …
Evaluation of a novel chromogenic medium for Candida spp. identification and comparison with CHROMagar™ Candida for the detection of Candida auris in…
2020
Abstract A shift to Candida non-albicans infections has been noted during the last years, and the emergence of multi-resistant Candida auris has complicated their management. The aim of this study was first to compare the performance of the novel chromogenic medium CHROMagar™ Candida Plus (CHROMagar, France) with CHROMagar™ Candida (Becton Dickinson, Germany) for the presumptive identification of Candida species; and then, to evaluate its utility in the detection of C. auris in surveillance samples. CHROMagar™ Candida Plus showed a good performance compared with the reference medium CHROMagar™ Candida. Sensitivity and specificity were 100% in both media for tested species at 48 h of incubat…
Validate or falsify: Lessons learned from a microscopy method claimed to be useful for detecting Borrelia and Babesia organisms in human blood.
2016
A modified microscopy protocol (the LM-method) was used to demonstrate what was interpreted as Borrelia spirochetes and later also Babesia sp., in peripheral blood from patients. The method gained much publicity, but was not validated prior to publication, which became the purpose of this study using appropriate scientific methodology, including a control group.Blood from 21 patients previously interpreted as positive for Borrelia and/or Babesia infection by the LM-method and 41 healthy controls without known history of tick bite were collected, blinded and analysed for these pathogens by microscopy in two laboratories by the LM-method and conventional method, respectively, by PCR methods i…
Evaluation of a rapid antigen test (Panbio™ COVID-19 Ag rapid test device) for SARS-CoV-2 detection in asymptomatic close contacts of COVID-19 patien…
2021
Objectives There is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio™ COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for this purpose. Methods A total of 634 individuals (355 female; median age, 37 years; range, 9–87) were enrolled. Two nasopharyngeal swabs were collected from household (n = 338) and non-household contacts (n = 296) of COVID-19 cases. RAD testing was carried out at the point of care. The RT-PCR test used was the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, MA, USA). Results Household contacts were tested at a median …
Performance of existing definitions and tests for the diagnosis of invasive aspergillosis in critically ill, adult patients: A systematic review with…
2020
Contains fulltext : 229471.pdf (Publisher’s version ) (Closed access) OBJECTIVES: To summarize the available evidence on the diagnostic performance for invasive aspergillosis (IA) in non-hematological, non-solid organ transplantation critically ill patients of the following: (i) existing definitions of IA (developed either for classical immunocompromised populations or for non-immunocompromised critically ill patients); (ii) laboratory tests; (iii) radiology tests. METHODS: A systematic review was performed by evaluating studies assessing the diagnostic performance for IA of a definition/s and/or laboratory/radiology test/s vs. a reference standard (histology) or a reference definition. RES…