Search results for "Sensitivity and specificity"

showing 10 items of 1080 documents

Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter de…

2011

Abstract A sensitive analytical method to concentrate and determine extensively used UV filters in cosmetic products at (ultra)trace levels in water samples is presented. The method is based on a sample treatment using dispersive solid-phase extraction (dSPE) with laboratory-made chemisorbed oleic acid-coated cobalt ferrite (CoFe 2 O 4 @oleic acid) magnetic nanoparticles (MNPs) as optimized sorbent for the target analytes. The variables involved in dSPE were studied and optimized in terms of sensitivity, and the optimum conditions were: mass of sorbent, 100 mg; donor phase volume, 75 mL; pH, 3; and sodium chloride concentration, 30% (w/v). After dSPE, the MNPs were eluted twice with 1.5 mL …

SorbentBiochemistrySensitivity and SpecificityGas Chromatography-Mass SpectrometryAnalytical ChemistryTap waterRiversSample preparationSolid phase extractionMagnetite NanoparticlesDetection limitChromatographyElutionChemistryOrganic ChemistryExtraction (chemistry)Osmolar ConcentrationSolid Phase ExtractionReproducibility of ResultsWaterGeneral MedicineHydrogen-Ion ConcentrationGas chromatography–mass spectrometrySunscreening AgentsWater Pollutants ChemicalOleic AcidJournal of chromatography. A
researchProduct

Application of matrix solid-phase dispersion to the determination of a new generation of fungicides in fruits and vegetables.

2002

A method based on matrix solid-phase dispersion (MSPD) and gas chromatography to determine eight fungicides in fruits and vegetables is described. Fungicide residues were identified and quantified using nitrogen-phosphorus detection and electron-capture detection connected in parallel and confirmed by mass spectrometric detection. The method required 0.5 g of sample, C18 bonded silica as dispersant sorbent, silica as clean-up sorbent and ethyl acetate as eluting solvent. Recoveries from spiked orange, apple, tomato, artichoke, carrot and courgette samples ranged from 62 to 102% and relative standard deviations were less than 15% in the concentration range 0.05-10 mg kg(-1). Detection and qu…

SorbentChromatographyChromatography GasChemistryOrganic ChemistryEthyl acetateGeneral MedicineReference StandardsBiochemistrySensitivity and SpecificityAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundElectron capture detectorFruitVegetablesAnhydrousSample preparationSolid phase extractionGas chromatographyCaptanJournal of chromatography. A
researchProduct

Preconcentration of emerging contaminants in environmental water samples by using silica supported Fe3O4 magnetic nanoparticles for improving mass de…

2011

A magnetic material based on Fe(3)O(4) magnetic nanoparticles incorporated in a silica matrix by using a sol-gel procedure has been used to extract and preconcentrate emerging contaminants such as acetylsalicylic acid, acetaminophen, diclofenac and ibuprofen from environmental water samples prior to the analysis with Capillary LC-MS. The use of the proposed silica supported Fe(3)O(4) magnetic nanoparticles enables surfactant free extracts for the analysis with MS detection without interferences in the ionisation step. Under the optimum conditions, we demonstrated the reusability of the magnetic sorbent material during 20 uses without loss in the extraction efficiency. In addition, no cleanu…

SorbentPortable water purificationMass spectrometryFerric CompoundsSensitivity and SpecificityBiochemistryMass SpectrometryWater PurificationAnalytical ChemistryAdsorptionRiversParticle SizeMagnetite NanoparticlesDetection limitChromatographyChemistrySolid Phase ExtractionOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineSilicon DioxidePharmaceutical PreparationsMagnetic nanoparticlesAdsorptionParticle sizeWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Routine application using single quadrupole liquid chromatography-mass spectrometry to pesticides analysis in citrus fruits.

2005

Abstract A rapid and sensitive liquid chromatography–electrospray ionization–mass spectrometry method has been developed for the routine analysis of buprofezin, bupirimate, hexaflumuron, tebufenpyrad, fluvalinate and pyriproxyfen in citrus fruits. Extracts were obtained by matrix solid-phase dispersion (MSPD) using C 18 as dispersant and dichloromethane-methanol (80:20, v/v) as eluent. Matrix effects were tested for all matrices by addition of standard to sample blank extracts (samples containing no detectable residues). Mean recoveries obtained at fortification levels between 0.01 and 5 mg kg −1 were 57–97% with relative standard deviations (RSDs) from 5 to 19%. The limits of quantificatio…

Spectrometry Mass Electrospray IonizationChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerMatrix (chemical analysis)Liquid chromatography–mass spectrometryFruitmedia_common.cataloged_instanceSample preparationSolid phase extractionEuropean unionPesticidesmedia_commonChromatography LiquidJournal of chromatography. A
researchProduct

Comparison of four mass analyzers for determining carbosulfan and its metabolites in citrus by liquid chromatography/mass spectrometry

2006

Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except …

Spectrometry Mass Electrospray IonizationChromatographyOrganic ChemistryAnalytical chemistryReproducibility of ResultsButylaminesMass spectrometrySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerDibutylamineCarbofuranchemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryQuadrupoleCarbosulfanCarbamatesQuadrupole ion trapChromatography High Pressure LiquidSpectroscopyCitrus sinensisRapid Communications in Mass Spectrometry
researchProduct

Direct infusion mass spectrometry as a fingerprint of protein-binding media used in works of art

2005

A direct infusion mass spectrometry method for the characterization of proteinaceous glues from binding media used in pictorial works of art prior to conservation or restoration treatment is proposed. Amino acids are released by acid hydrolysis and dissolved in a mixture of acidic water and ethanol. This mixture is directly infused into a mass spectrometer without any derivatization. The mass spectrometer is operated in positive ion electrospray mode (ESI-MS) to yield [M+H]+ ions for the amino acids. Relative amounts of each amino acid are calculated for each protein (beef and porcine gelatines, albumin, casein and egg). The analyzed proteins were satisfactorily distinguished. The method is…

Spectrometry Mass Electrospray IonizationElectrosprayResolution (mass spectrometry)Protein mass spectrometrySwineMass spectrometryPeptide MappingSensitivity and SpecificitySample preparation in mass spectrometryAnalytical Chemistrychemistry.chemical_compoundAdhesivesAnimalsAmino AcidsDerivatizationSpectroscopychemistry.chemical_classificationChromatographyHydrolysisOrganic ChemistryProteinsReproducibility of ResultsAmino acidchemistryCattlePaintingsAcid hydrolysisProtein BindingRapid Communications in Mass Spectrometry
researchProduct

Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer.

2009

Objective This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. Design and methods Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. Results The CMIA total %CV's were all < 8% and the Limit of Quantification (LOQ) was < 1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R ≥ 0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R ≥ 0.94 at…

Spectrum analyzerClinical BiochemistryHematocritSensitivity and Specificitylaw.inventionMagneticslawAntibody SpecificityTandem Mass SpectrometrymedicineHumansParticle SizeChemiluminescenceDetection limitImmunoassaySirolimusChromatographymedicine.diagnostic_testChemistryMulti siteGeneral MedicineImmunoassay methodImmunoassayLuminescent MeasurementsPositive biasImmunosuppressive AgentsChromatography LiquidClinical biochemistry
researchProduct

Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis

2008

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluat…

SpirometryCorrelation coefficientSwineSulfur HexafluorideBiomedical EngineeringBiophysicsAnalytical chemistrychemistry.chemical_elementFraction (chemistry)Sensitivity and SpecificityOxygenchemistry.chemical_compoundNuclear magnetic resonanceAdministration InhalationmedicineAnimalsRadiology Nuclear Medicine and imagingRespiratory systemLungReproducibilitymedicine.diagnostic_testPulmonary Gas ExchangeReproducibility of ResultsMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingSulfur hexafluorideBreath TestschemistrySpirometryMagnetic Resonance Imaging
researchProduct

A model-based approach for assessing bronchodilator responsiveness in children: The conventional cutoff revisited

2020

An increase in FEV1 >=12% has been proposed in international guidelines as a clue to airway reversibility for diagnosing asthma in both adults and children. However, the validity of this cut-off has been questioned in the pediatric population. The aim of this study was to provide evidence that different cut-off values in BDR may be associated with better performance in discriminating among outpatient children with naïve asthma (A) and without asthma (NA). We compared three approaches: i) the conventional cutoff (12%); ii) the cut-off estimated by Youden's criteria; and iii) the cut-off based on a model-driven approach. we found that the conventional cut-off of 12% showed poor sensitivity in…

SpirometryMalePediatricsmedicine.medical_specialtycut-offAdolescentmedicine.drug_classImmunologyspirometrySensitivity and Specificitysegmented modelchildrenReference ValuesBronchodilatorForced Expiratory VolumeImmunology and AllergyMedicineCutoffHumansChildAsthmaModels Statisticalmedicine.diagnostic_testbusiness.industryasthmachildren asthma spirometry bronchodilator response cut-offmedicine.diseaseBronchodilator AgentsChild PreschoolFemalebronchodilator responsedynamic nomogrambusiness
researchProduct

Monitoring response to treatment in asthma management: food for thought

2004

Asthma is a chronic inflammatory disorder of the airways that is characterized by episodic symptoms. In this regard, asthma management has classically involved periodic re-assessment by the health-care provider, during which therapy is altered mainly based on clinical and physiological parameters, such as assessment of symptoms, spirometry and peak expiratory flow monitoring. In this context, various markers of airway inflammation (e.g. eosinophils in the induced sputum, nitric oxide in the exhaled air) have been proposed to assess the severity of asthma and to adjust the therapy accordingly. The evaluation of airway hyper-responsiveness with different stimuli has also been suggested as a n…

Spirometrymedicine.medical_specialtyAllergyImmunologyBronchiPeak Expiratory Flow RateContext (language use)Settore MED/10 - Malattie Dell'Apparato RespiratorioSensitivity and SpecificityBronchial Provocation TestsQuality of lifeSurveys and QuestionnairesmedicineHumansImmunology and AllergyIntensive care medicineLungAsthmamedicine.diagnostic_testbusiness.industryRespiratory diseaseSputummedicine.diseaseAsthmarespiratory tract diseasesTreatment OutcomeBreath TestsSpirometryChronic DiseaseImmunologyQuality of LifeSputumasthma treatment biomarkersmedicine.symptombusinessAirway
researchProduct