Search results for "Senso"

showing 10 items of 4750 documents

Immunohistochemical profile of human pancreatic pacinian corpuscles.

2010

To analyze the immunohistochemical profile of the human pancreatic pacinian corpuscles in comparison with that of the cutaneous pacinian corpuscles. In addition, we studied a Pacinilike corpuscle found in the adventitia of a pancreatic artery.We used immunohistochemistry to detect specific antigens for corpuscular constituents, specific antibodies for the identification of Adelta- and C-sensory fibers and for the detection of several growth factor receptors, and some members of the degenerin/epithelial Na channel superfamily of proteins.Approximately 62% of pancreatic pacinian corpuscles have 2 to 10 axonic profiles each enclosed by its own inner core: 1 or 2 of these axonic profiles displa…

AdultMalePathologymedicine.medical_specialtySensory Receptor CellsEndocrinology Diabetes and MetabolismNerve Tissue ProteinsEndocrinologyAdventitiaGlial Fibrillary Acidic ProteinInternal MedicinemedicineHumansReceptor trkBReceptors Growth FactorEpithelial Sodium ChannelsPancreasHepatologybusiness.industryMucin-1AnatomyMiddle AgedImmunohistochemistryAcid Sensing Ion Channelsmedicine.anatomical_structureDegenerin Sodium ChannelsImmunohistochemistryPancreasbusinessPacinian CorpusclesPacinian CorpusclePancreas
researchProduct

PREGO (presentation of Graves' orbitopathy) study: changes in referral patterns to European Group On Graves' Orbitopathy (EUGOGO) centres over the pe…

2015

BACKGROUND/AIMS: The epidemiology of Graves' orbitopathy (GO) may be changing. The aim of the study was to identify trends in presentation of GO to tertiary centres and initial management over time.METHODS: Prospective observational study of European Group On Graves' Orbitopathy (EUGOGO) centres. All new referrals with a diagnosis of GO over a 4-month period in 2012 were included. Clinical and demographic characteristics, referral timelines and initial decisions about management were recorded. The data were compared with a similar EUGOGO survey performed in 2000.RESULTS: The demographic characteristics of 269 patients studied in 2012 were similar to those collected in the year 2000, includi…

AdultMalePediatricsmedicine.medical_specialtyReferralEpidemiologyMedizin030209 endocrinology & metabolismGraves' ophthalmopathyTertiary Care Centers03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineEpidemiologymedicinePrevalenceHumansEpidemiology; Orbit; Ophthalmology; Sensory Systems; Cellular and Molecular NeuroscienceProspective StudiesProspective cohort studyReferral and Consultationbusiness.industryThyroid diseaseMiddle Agedmedicine.diseaseSensory SystemsEuropeGraves OphthalmopathyOphthalmologyCohort030221 ophthalmology & optometryObservational studyFemalesense organsPresentation (obstetrics)businessOrbitBritish journal of ophthalmology
researchProduct

Prevalence and causes of blindness and low vision in the Casteldaccia Eye Study.

1994

In a population-based survey performed on the middle-aged and elderly population of Casteldaccia, Sicily, we found that the prevalence of blindness was 0.47% and the prevalence of low vision 1.22%. Unilateral blindness affected 2.81% of the population and unilateral low vision 4.12%. Visual impairment was much more frequently seen in subjects aged 70 years or more than in younger persons. The main cause of visual impairment was cataract, followed by amblyopia, which was responsible for many cases of unilateral low vision.

AdultMalePediatricsmedicine.medical_specialtygenetic structuresEye DiseasesEye diseasePopulationVisual impairmentVision LowBlindnessVision disorderCellular and Molecular NeurosciencePrevalenceMedicineHumanseducationAgededucation.field_of_studyBlindnessbusiness.industryPublic healthMiddle Agedmedicine.diseasehumanitieseye diseasesSensory SystemsLow visionOphthalmologyItalyEtiologyFemalemedicine.symptombusinessGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Persistent antinociception through repeated self-injury in patients with borderline personality disorder.

2012

Abstract Patients with borderline personality disorder, mostly female, exhibit severe autoaggressive behavior, namely an intentionally performed, nonsuicidal self-injury and severe blunting of pain perception, the mechanism of which is hitherto not understood. Because the nociceptive system displays a high degree of plasticity, the aim of this study was to analyze the relationship of pain perception to self-injurious behavior. Pain perception of mechanical and chemical noxious stimuli was studied by quantitative sensory testing in 22 patients (15 female, 7 male) with borderline personality disorder (BPD) according to DSM-IV and 22 age- and gender-matched controls. BPD patients exhibited a s…

AdultMalePersonality InventoryPsychometricsPoison controlStimulationYoung AdultBorderline Personality DisorderPhysical StimulationThreshold of painInjury preventionmedicineNoxious stimulusPsychophysicsHumansBorderline personality disorderPain MeasurementPsychiatric Status Rating ScalesAnalysis of VariancePain Perceptionmedicine.diseaseAnesthesiology and Pain MedicineNociceptionNeurologyAnesthesiaCase-Control StudiesSensory System AgentsPain catastrophizingFemaleNeurology (clinical)CapsaicinPsychologySelf-Injurious BehaviorPainReferences
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Modulatory effects of low- and high-frequency repetitive transcranial magnetic stimulation on visual cortex of healthy subjects undergoing light depr…

2005

The aim of the present study was to explore further the effects of light deprivation (LD) on visual cortex excitability. Healthy subjects reporting reliable induction of phosphenes by occipital transcranial magnetic stimulation (TMS) underwent 60 min of complete LD. Phosphene threshold (PT) was measured before (T0), after 45 min (T1) and 60 min (T2) of LD, and then every 10 min after light re-exposure until recovery to T0 values. Repetitive TMS (rTMS) (at 1 or 10 Hz) was applied in separate sessions during the last 15 min of LD. PTs significantly decreased after 45 min of LD. rTMS differentially modified the effects of 60 min LD on PTs depending on stimulation frequency. One hertz rTMS did …

AdultMalePhosphenesNeural Inhibition/physiology Phosphenes/physiology Photic Stimulation Sensory Deprivation/physiology Transcranial Magnetic Stimulation Visual Cortex/physiologyNeural InhibitionMiddle AgedTranscranial Magnetic StimulationElectric StimulationIntegrative PhysiologyHumansFemaleSensory DeprivationPhotic StimulationVisual CortexThe Journal of physiology
researchProduct

Feasibility and reproducibility of electroencephalography-based corticokinematic coherence

2020

Corticokinematic coherence (CKC) is the phase coupling between limb kinematics and cortical neurophysiological signals, reflecting cortical processing of proprioceptive afference, and it is reproducible when estimated with magnetoencephalography (MEG). However, feasibility and reproducibility of CKC based on electroencephalography (EEG) is still unclear and is the primary object of the present report. Thirteen healthy right-handed volunteers (seven females, 21.7 ± 4.3 yr) participated in two combined MEG/EEG sessions 12.6 ± 1.3 mo apart. Participants' dominant and nondominant index finger was continuously moved at 3 Hz for 4 min separately using a pneumatic-movement actuator. Coherence was …

AdultMalePhysiologyComputer scienceMovementproprioceptionKinematicsElectroencephalographyFunctional Laterality050105 experimental psychologysomatosensoryFingersYoung Adult03 medical and health sciences0302 clinical medicineEvoked Potentials SomatosensorymedicineHumans0501 psychology and cognitive sciencesComputer visionEEGrepeatabilityReproducibilityliikeaistimedicine.diagnostic_testProprioceptiontoistettavuusbusiness.industryGeneral Neuroscience05 social sciencesMagnetoencephalographyReproducibility of ResultsSomatosensory CortexCoherence (statistics)Sciences bio-médicales et agricolesneurotieteetBiomechanical Phenomena3. Good healthkinematicsFeasibility StudiesFemalebiomekaniikkaArtificial intelligencebusiness030217 neurology & neurosurgeryelectroencephalography
researchProduct