Search results for "Sensory Systems"
showing 10 items of 793 documents
The frequency effect for pseudowords in the lexical decision task
2005
Four experiments were designed to investigate whether the frequency of words used to create pseudowords plays an important role in lexical decision. Computational models of the lexical decision task (e.g., the dual route cascaded model and the multiple read-out model) predict that latencies to low-frequency pseudowords should be faster than latencies to high-frequency pseudowords. Consistent with this prediction, results showed that when the pseudowords were created by replacing one internal letter of the base word (Experiments 1 and 3), high-frequency pseudowords yielded slower latencies than low-frequency pseudowords. However, this effect occurred only in the leading edge of the response …
Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients
2016
The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.
Modulation transfer function: Rigid versus foldable phakic intraocular lenses
2008
Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…
Identification of Novel Molecular Components of the Photoreceptor Connecting Cilium by Immunoscreens
2002
Abstract The connecting cilium of photoreceptor cells is the only intracellular link between the morphologically, functionally and biochemically different compartments of the inner and outer segments. The non-motile modified cilium plays an important role in the organization and the function of photoreceptor cells, namely in delivery and turnover of enzymes and substrates of the visual transduction cascade, and the photosensitive membranes of the outer segment. The protein components of the cilium participate in the intracellular transport through the cilium, in the outer segment disk morphogenesis and in the maintenance of discrete membrane domains. In order to identify yet unknown cytoske…
Photoreceptor vitality in organotypic cultures of mature vertebrate retinas validated by light-dependent molecular movements
2006
AbstractVertebrate photoreceptor cells are polarized neurons highly specialized for light absorption and visual signal transduction. Photoreceptor cells consist of the light sensitive outer segment and the biosynthetic active inner segment linked by a slender connecting cilium. The function of mature photoreceptor cells is strictly dependent on this compartmentalization which is maintained in the specialized retinal environment. To keep this fragile morphologic and functional composition for further cell biological studies and treatments we established organotypic retina cultures of mature mice and Xenopus laevis. The organotypic retina cultures of both model organisms are created as co-cul…
Small field motion detection in goldfish is red-green color blind and mediated by the M-cone type
2007
Large field motion detection in goldfish, measured in the optomotor response, is based on the L-cone type, and is therefore color-blind (Schaerer & Neumeyer, 1996). In experiments using a two-choice training procedure, we investigated now whether the same holds for the detection of a small moving object (size: 8 mm diameter; velocity: 7 cm/s). In initial experiments, we found that goldfish did not discriminate between a moving and a stationary stimulus, obviously not taking attention to the cue “moving.” Therefore, random dot patterns were used in which the stimulus was visible only when moving. Using black and white random dot patterns with variable contrast between 0.2 and 1, we found…
Sperrarterien in der Aderhaut und am Sehnerveneintritt beim Hund.
1954
In der Aderhaut und am Sehnerveneintritt beim Hund werden Sperrarterien beschrieben, die mit zahlreichen Langsmuskelpolstern in der Intima ausgestattet sind und offenbar der Regulation der Aderhautdurchblutung dienen. Auch andere Besonderheiten am Gefassystem im Bereich des Sehnerveneintritts (Venenplexus, arteriovenose Anastomosen) konnten nachgewiesen werden. Weder bei der Katze, beim Kaninchen, Meerschweinchen oder Menschen kommen ahnliche Gefasregulationseinrichtungen vor.
In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.
2013
Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …
Fourier analysis of the stimuli for pattern-induced flicker colors.
1992
Pattern-induced flicker colors (PIFCs) were observed and color matched in rotating discs from which higher-harmonic Fourier components in the square-wave temporal luminance functions of a conventional black-and-white Benham disc had been removed. Since both reddish-brown and blue PIFCs were visible with purely sinusoidal stimuli they cannot result from differences in temporal stimulus shape or pattern and do not provide evidence for a temporal coding theory of color. Green PIFCs differed in that they did require the presence of additional harmonics. In a second experiment the luminance means upon which the sinusoidal PIFC stimuli were imposed were varied. The results show that color is dete…