On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers
2020
Abstract A tracking detector composed of scintillator bars with a triangular cross-section read out by silicon photomultipliers in analog mode was developed. The tracker was designed to instrument a low density spectrometer for neutrino experiments. The performance of the system has been studied by exposing it to charged particle beams at the CERN-PS. The tests have shown that the position resolution in reconstructing charged particles’ tracks is within 2.2 mm over the momentum range 0.5–10 GeV/c.
High performance detector head for PET and PET/MR with continuous crystals and SiPMs
2012
International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…
Caracterización y modelización de detectores basados en la tecnología Cristal Continuo/SiPM para escáneres de tomografía por emisión de positrones
2012
El grupo IRIS (Image Reconstruction Instrumentation and Simulations for medical imaging applications) del Instituto de Física Corpuscular (IFIC) ha desarrollado un prototipo de un tomógrafo PET con dos cabezas giratorias basado en cristales continuos acoplados a unos nuevos fotodetectores conocidos como fotomultiplicadores de silicio (SiPM). En un futuro se quiere construir un anillo completo y se está considerando el uso de geometrías alternativas, como la sustitución de los cristales cuboides por cristales trapezoidales con el fin de evitar los huecos entre cristales adyacentes. El uso de estos cristales permitiría mejorar la eficiencia y la calidad de la reconstrucción de la imagen. El o…
Silicon Photomultipliers Signal-to-Noise Ratio in the Continuous Wave Regime
2014
Abstract— We report on Signal-to-Noise Ratio measurements carried out, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a class of silicon photomultipliers fabricated in planar technology on silicon p- type substrate. Signal-to-Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the same current. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal-to-Noise Ratio, as a function of the tempe…
Responsivity measurements of N-on-P and P-on-N silicon photomultipliers in the continuous wave regime
2013
We report the electrical and optical comparison, in continuous wave regime, of two novel classes of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon P-type and N-type substrate respectively. Responsivity measurements have been performed with an incident optical power from tenths of picowatts to hundreds of nanowatts and on a broad spectrum, ranging from ultraviolet to near infrared (340-820 nm). For both classes of investigated SiPMs, responsivity shows flat response versus the optical incident power, when a preset overvoltage and wavelength is applied . More in detail, this linear behavior extends up to about 10 nW for lower overvoltages, while a shrink is observ…
P-on-N and N-on-P silicon photomultipliers: an in-depth analysis in the continuous wave regime
2013
We report on the electrical and optical comparison, in the continuous wave regime, of two novel classes of silicon photomultipliers fabricated in planar technology on silicon P-type (N-on-P class) and N-type (P-on-N class) substrates respectively.
Time Of Flight measurements via two LiDAR systems with SiPM and APD
2016
In this paper, we present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.
The AX-PET demonstrator—Design, construction and characterization
2011
Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …
SNR measurements of silicon photomultipliers in the continuous wave regime
2014
We report on our Signal-to-Noise Ratio (SNR) measurements carried out, in the continuous wave regime, at different frequencies and at various temperatures, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate. SNR of SiPMs is given by the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square (RMS) deviation of the same current. In our measurements, we have employed a 10 Hz equivalent noise bandwidth, around the lock-in amplifier reference frequency. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current, while background light …
Proceedings of the Closed Round Table and Italian Consensus on the Medication-Related Osteonecrosis of Jaws (MRONJ) at the Symposium of Italian Socie…
2019
On 20 October 2018 a Closed Round Table brought together a wide range of stakeholders from several medical disciplines, including academic experts, dentists, oncologists, maxillo-facial surgeons, oral surgeons, radiologists, under the technical and scientific coordination of Giuseppina Campisi (for SIPMO) and Giacomo Oteri (for Italian Society of Oral Surgery- SIdCO)