Search results for "Sign"
showing 10 items of 14733 documents
Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invas…
2017
Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation. Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hype…
IAPs: more than just inhibitors of apoptosis proteins.
2008
Inhibitors of apoptosis proteins (IAPs) are a conserved family of proteins identified in species ranging from virus, yeasts, nematodes, fishes, flies and mammals. The common structural feature is the presence of at least one Baculovirus IAP Repeat (BIR) domain. Hence, IAPs are also known as BIR-containing proteins (BIRCs). Most of them display anti-apoptotic properties when overexpressed. In drosophila, IAPs are sufficient and necessary to promote cell survival through a direct regulation of apoptotic proteases called caspases. In mammals, BIRC4/XIAP, the most studied IAP member can directly inhibit the activity of caspase-3, 7 and 9. However, this activity is not conserved in other IAPs an…
Optimal positioning of the humeral component in the reverse shoulder prosthesis.
2014
Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…
Changes in spinal range of motion after a flexibility training program in elderly women
2014
Giuseppe Battaglia,1,2 Marianna Bellafiore,1,2 Giovanni Caramazza,2 Antonio Paoli,3 Antonino Bianco,1,2 Antonio Palma1,2 1Department of Law, Society, and Sport Sciences, University of Palermo, Palermo, Italy; 2Sicilian Regional Sports School of Italian National Olympic Committee (CONI), Sicily, Italy; 3Department of Biomedical Sciences, University of Padova, Padova, Italy Background: Aging-related reduced spinal mobility can interfere with the execution of important functional skills and activities in elderly women. Although several studies have shown positive outcomes in response to spinal flexibility training programs, little is known about the management of sets and repetitions in traini…
Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences
2020
Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…
2021
Vibroarthrography measures joint sounds caused by sliding of the joint surfaces over each other. and can be affected by joint health, load and type of movement. Since both warm-up and muscle fatigue lead to local changes in the knee joint (e.g., temperature increase, lubrication of the joint, muscle activation), these may impact knee joint sounds. Therefore, this study investigates the effects of warm-up and muscle fatiguing exercise on knee joint sounds during an activity of daily living. Seventeen healthy, physically active volunteers (25.7 ± 2 years, 7 males) performed a control and an intervention session with a wash-out phase of one week. The control session consisted of sitting on a c…
Molekulare Signalwege der aseptischen Endoprothesenlockerung (Molecular pathways in aseptic loosening of orthopaedic endoprosthesis)
2008
Operative joint replacement to treat disabling joint conditions secondary to degenerative and inflammatory arthritides has become one of the most efficacious and cost-effective procedures to relieve pain and restore joint function. However, prosthetic implants are not built to last forever and osteolysis and aseptic loosening has been associated with prosthetic arthroplasties since their introduction. The functional life of a synthetic joint is influenced by many factors including the material of the implant, operation procedures and the surgeon involved, as well as patient-related factors. Although promising developments have been achieved in this field, more than 10% of all implants still…
The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement
1992
Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.
In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill
2020
Objective: An in vitro study was made to compare mean thermal variation according to the material, design and wear of the surgical drills used during dental implant site preparation. Material and methods: Three study groups (stainless steel drills with straight blades
Storie di oggetti (e di sogni) perduti. Musei contemporanei per ritrovarsi
2022
What happens to humanity discarded by history? To the broken dreams (of love and life)?What to do with the objects that fill our life as "fragile ruins" of a dream lost forever? The article, looking at various contemporary projects of permanent museums and temporary exhibitions, intends to outline and lead a reflection on the radical paradigm change that intervenes in the exhibition processes and in the strategies of emotional engagement within contemporary museological policies. Conceived as places of encounter and relationship, museums are open to communities and individual stories. In particular, the emotion of lost guided the constitution of collections of objects, in a series of exhibi…