Search results for "Silicon photomultiplier"

showing 10 items of 87 documents

Characterization of SiPM properties at liquid nitrogen temperature

2016

SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…

Materials scienceSiliconPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industrychemistry.chemical_elementCryogenicsLiquid nitrogen01 natural sciencesSpectral linelaw.inventionSilicon photomultiplierchemistrylaw0103 physical sciencesOptoelectronicsBreakdown voltagePhotonicsResistorbusiness2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
researchProduct

Performance of sensl C-Series SiPM with high photoelectron resolution at cryogenic temperatures

2016

The C-Series of silicon photomultipliers (SiPM) from SensL provides devices with a fast response and high performance at low cost. The device's ability to detect light at temperatures of liquid nitrogen (77K) and liquid helium (4 K) with high photoelectron resolution was demonstrated. Results include relative photon detection efficiency (PDE), gain, microcell capacitance, and cross-talk probability at different over-voltages, both at room and at cryogenic temperatures. At 77K the SiPM demonstrated significantly improved operating characteristics while at 4K the observed increase in break-down voltage, the reduction of PDE by a factor of 2-3, and the extensively dropped microcell capacitance…

Materials sciencebusiness.industryLiquid heliumchemistry.chemical_elementLiquid nitrogenCapacitancelaw.inventionSilicon photomultiplierchemistrylawElectronic engineeringOptoelectronicsMicrocellPhotonicsbusinessHeliumVoltage2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
researchProduct

Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs

2011

International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsCompton telescopeSiPM01 natural sciences7. Clean energyCoincidence030218 nuclear medicine & medical imaginglaw.inventionTelescope03 medical and health sciencesHadron therapy0302 clinical medicineOpticsSilicon photomultiplierApplication-specific integrated circuitlaw0103 physical sciencesCompton imaging[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationPhysicsContinuous crystal010308 nuclear & particles physicsbusiness.industryResolution (electron density)DetectorMPPCG-APDLaBr3Full width at half maximumbusiness
researchProduct

High resolution detectors based on continuous crystals and SiPMs for small animal PET

2012

International audience; Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate γ-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating sub-millimetre intrinsic spatial resolution. A system consisting in two rotating det…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsSiPMMonte Carlo methodHigh resolution01 natural sciencesCoincidence030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplierPosition (vector)0103 physical sciencesHigh resolutionSensitivity (control systems)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorPosition determinationPETMonolithic crystalsbusiness
researchProduct

On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers

2020

Abstract A tracking detector composed of scintillator bars with a triangular cross-section read out by silicon photomultipliers in analog mode was developed. The tracker was designed to instrument a low density spectrometer for neutrino experiments. The performance of the system has been studied by exposing it to charged particle beams at the CERN-PS. The tests have shown that the position resolution in reconstructing charged particles’ tracks is within 2.2 mm over the momentum range 0.5–10 GeV/c.

Nuclear and High Energy PhysicsScintillators SiPM Particle tracking device Position resolutionParticle tracking devicePhysics::Instrumentation and DetectorsSiPMScintillatorTracking (particle physics)01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplierParticle tracking device Position resolution Scintillators SiPM0103 physical sciencesInstrumentationPhysicsRange (particle radiation)Spectrometer010308 nuclear & particles physicsbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorCharged particleScintillatorsPosition resolutionHigh Energy Physics::ExperimentNeutrinobusiness
researchProduct

First Compton telescope prototype based on continuous LaBr3-SiPM detectors

2013

Abstract A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16×18×5 mm 3 LaBr 3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3×3 mm 3 in a 4.5×4.05 mm 2 pitch. The second detector, selected by availability, consists of a continuous 16×18×5 mm 3 LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a 22 Na source placed at different positions and images have been reconstructed with…

Nuclear and High Energy Physicsmedicine.medical_specialtyCompton telescopeIntegrated circuitScintillator01 natural sciences7. Clean energyLyso-030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineSilicon photomultiplierOpticslaw0103 physical sciencesmedicineMedical physicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorCompton scatteringbusinessNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

High performance detector head for PET and PET/MR with continuous crystals and SiPMs

2012

International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…

Nuclear and High Energy Physicsmedicine.medical_specialtySiPMIterative reconstruction01 natural sciencesParticle detectorLyso-030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier0103 physical sciencesmedicineMedical physicsHigh resolution[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorPosition determinationSemiconductor detectorFull width at half maximumMG-APDPETMonolithic crystalsbusiness
researchProduct

Si photomultipliers for bio-sensing applications

2016

In this paper, silicon photomultipliers (SiPM) are proposed as optical detectors for bio sensing. Optical transduction is the most used detection mechanism in many biosensor applications, such as DNA microarray and real-time polymerase chain reaction. The performances of a 25 pixels device used for both applications are studied. The results confirm that the SiPM is more sensitive than the traditionally employed detectors. In fact, it is able to experimentally detect 1 nM and 100 fM of fluorophore concentrations in dried samples and solutions, respectively. We present and discuss in details the detector configuration and its characterization as fluorescence detector for bio sensing.

Optical biosensor systemPhotomultiplierFluorophoreMaterials sciencePixel010308 nuclear & particles physics010401 analytical chemistryDetectorDNA microarrayDNA microarray Optical biosensor system RT PCR Silicon PhotomultipliersNanotechnologySilicon Photomultipliers01 natural sciencesFluorescenceSettore ING-INF/01 - ElettronicaAtomic and Molecular Physics and OpticsFluorescence spectroscopy0104 chemical scienceschemistry.chemical_compoundSilicon photomultiplierchemistry0103 physical sciencesElectrical and Electronic EngineeringBiosensorRT PCR
researchProduct

Design and implementation of a portable fNIRS embedded system

2015

We report on the design, development and operation of a portable, low cost, battery-operated, multi-channel, functional Near Infrared Spectroscopy embedded system, hosting up to 64 optical sources and 128 Silicon PhotoMultiplier optical detectors. The system is realized as a scalable architecture, whose elementary leaf consists of a probe board provided with 16 SiPMs, 4 couples of bi-color LED, and a temperature sensor, built on a flexible stand. The hardware structure is very versatile because it is possible to handle both the switching time of the LED and the acquisition of the photodetectors, via an ARM based microcontroller.

Optical detectorsbusiness.industryComputer sciencePhotodetectorInfrared spectroscopyScalable architectureSilicon photomultiplierSettore ING-INF/01 - ElettronicaIndustrial and Manufacturing EngineeringSwitching timeMicrocontrollerSilicon photomultiplierEmbedded systemFunctional near-infrared spectroscopyFNIRS embedded systembusinessInfrared spectroscopyComputer hardware
researchProduct

Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array

2013

NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas, demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent e…

PhotomultiplierMECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURASPhysics - Instrumentation and DetectorsPhysical measurementsParticle tracking detectors (Gaseous detectors)Time projection chambersPattern recognition SystemsFísica -- Mesuramentschemistry.chemical_elementFOS: Physical sciencesTracking (particle physics)01 natural sciences7. Clean energyTECNOLOGIA ELECTRONICAXenonSilicon photomultiplierOpticsCluster analysisDouble beta decayPattern recognition0103 physical sciencesCalibrationReconeixement de formes (Informàtica)Calibratge010306 general physicsInstrumentationImage resolutionMathematical PhysicsDetectors de radiacióPhysicsCalibration and fitting methods010308 nuclear & particles physicsbusiness.industryDetectorCluster findingFísicaInstrumentation and Detectors (physics.ins-det)Double-beta decay detectorsAnàlisi de conglomeratschemistryNuclear countersCalibrationbusiness
researchProduct