Search results for "Silicon"

showing 10 items of 1391 documents

Gain stabilization and noise minimization for SiPMs at cryogenic temperatures

2018

Abstract The performance of solid-state photon detectors such as avalanche photodiodes or silicon photomultipliers (SiPMs) is strongly affected by temperature. Important device characteristics for the detection of low light levels or single photons are photon detection efficiency, dark noise, and gain. In the present work the C-series SiPMs from SensL was characterized in cryogenic environments. At 77  K the SiPMs proved to be an excellent choice for single photon detection and an operation point with minimum noise contributions was found. At 4  K the performance was degraded, exhibiting a smaller gain and a larger noise.

PhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and Detectorsbusiness.industryLiquid heliumLiquid nitrogenAvalanche photodiodeNoise (electronics)law.inventionNoise minimizationSilicon photomultiplierlawOptoelectronicsbusinessInstrumentationDark currentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

AX-PET: A novel PET concept with G-APD readout

2012

Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS s…

PhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorCompton scatteringField of viewLyso-030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier030220 oncology & carcinogenesisTomographybusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Measurement of the response of Silicon Photomultipliers from single photon detection to saturation

2019

Abstract The development of Silicon Photomultipliers (SiPM) is very dynamic and a large variety of types exists. Important SiPM characteristics include the size and number of pixels, the gain, the photon detection efficiency (PDE), the recovery time, and correlated noise. SiPMs are particularly suitable for single-photon detection and low-intensity exposures. For photon numbers (PDE corrected) reaching the number of pixels, however, the sensors saturate. In this work, we present comprehensive response measurements for state-of-the-art SiPMs using an experimental setup based on a tunable picosecond laser. Several models are applied to the measured response curves, taking particularly correla…

PhysicsNuclear and High Energy PhysicsPhotonPicosecond laserPixelPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryDynamic range01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier0103 physical sciencesParticle physics experimentsbusinessInstrumentationPhoton detectionSaturation (magnetic)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Channeling experiments with sub-GeV electrons in flat silicon single crystals

2015

Abstract Various planar channeling experiments, performed at the Mainz Microtron MAMI with electrons at silicon single crystals, have been reanalyzed. Two types of signals have been employed. The low energy loss signal originates from emission of channeling radiation in the energy domain between 0.4 and 9 MeV while the high energy loss signal from electrons which have lost about 50% of their primary energy by emission of bremsstrahlung photons. The (1 1 0) planar channeling data, taken at a beam energy of 855 MeV with the former signal, can well be described on the basis of the solution of the classical Fokker–Planck equation. The measurements with the latter signal at beam energies between…

PhysicsNuclear and High Energy PhysicsPhotonSiliconBremsstrahlungchemistry.chemical_elementElectronRadiationCrystalchemistryAtomic physicsNuclear ExperimentInstrumentationMicrotronBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A novel experimental system for the KDK measurement of the 40K decay scheme relevant for rare event searches

2020

Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source …

PhysicsNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsDecay schemeSilicon drift detectorSpectrometerPhysics::Instrumentation and Detectors010308 nuclear & particles physicsElectron captureBranching fractionDetectorFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Scintillator7. Clean energy01 natural sciencesNuclear physics0103 physical sciencesNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentInstrumentationEvent (particle physics)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A low-noise and fast pre-amplifier and readout system for SiPMs

2015

Abstract To operate silicon photomultipliers (SiPMs) in a demanding environment with large temperature gradients, different amplifier concepts were characterized by analyzing SiPM pulse-shapes and charge distributions. A fully differential 4-wire SiPM pre-amplifier with separated tracks for the bias voltage and with good common-mode noise suppression was developed and successfully tested. To achieve highest single-pixel resolutions an online after-pulse and pile-up suppression was realized with fast readout electronics based on digital filters.

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsPreamplifierbusiness.industryAmplifierReadout electronicsCharge (physics)BiasingLow noiseSilicon photomultiplierOptoelectronicsbusinessInstrumentationDigital filterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The AX-PET demonstrator—Design, construction and characterization

2011

Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorPhase (waves)STRIPSLyso-law.inventionSilicon photomultiplierData acquisitionOpticsCardinal pointpet; axial geometry; brain; scanner; sipm; detector; geiger-mode avalanche photo diodes (g-apd)lawbusinessInstrumentationDiodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The large-area hybrid-optics CLAS12 RICH detector: Tests of innovative components

2014

A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two…

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryScatteringCherenkov detectorDetectorHadronHadronizationlaw.inventionNuclear physicsOpticsSilicon photomultiplierlawHadron spectroscopyHigh Energy Physics::ExperimentNuclear ExperimentbusinessInstrumentationCherenkov radiation
researchProduct

Laser tests of silicon detectors

2007

This paper collects experiences from the development of a silicon sensor laser testing setup and from tests of silicon strip modules (ATLAS End-cap SCT), pixel modules (DEPFET) and large-area diodes using semiconductor lasers. Lasers of 1060 and 680 nm wavelengths were used. A sophisticated method of focusing the laser was developed. Timing and interstrip properties of modules were measured. Analysis of optical effects involved and detailed discussion about the usability of laser testing for particle detectors are presented.

PhysicsNuclear and High Energy PhysicsPixelSiliconPhysics::Instrumentation and Detectorsbusiness.industryDetectorPhysics::Opticschemistry.chemical_elementLaserlaw.inventionSemiconductor laser theorySemiconductor detectorchemistrylawOptoelectronicsPhysics::Atomic PhysicsbusinessInstrumentationDiodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Timing results using an FPGA-based TDC with large arrays of 144 SiPMs

2015

Silicon photomultipliers (SiPMs) have become an alternative to traditional tubes due to several features. However, their implementation to form large arrays is still a challenge especially due to their relatively high intrinsic noise, depending on the chosen readout. In this contribution, two modules composed of SiPMs with an area of roughly mm mm are used in coincidence. Coincidence resolving time (CRT) results with a field-programmable gate array, in combination with a time to digital converter, are shown as a function of both the sensor bias voltage and the digitizer threshold. The dependence of the CRT on the sensor matrix temperature, the amount of SiPM active area and the crystal type…

PhysicsNuclear and High Energy PhysicsPixelbusiness.industryDetectorBiasingNoise (electronics)Time-to-digital converterFull width at half maximumSilicon radiation detectorsSilicon photomultiplierOpticsNuclear Energy and EngineeringGate arrayPositron emission tomography (PET)Nuclear medicineTEORIA DE LA SEÑAL Y COMUNICACIONESElectronic engineeringTrigger circuitsElectrical and Electronic Engineeringbusiness
researchProduct