Designing Medical Devices Based on Silicon Polymeric Material with Controlled Release of Local Anesthetics
2012
The drug delivery systems that are the object of this article take the form of a polymer matrix made of silicone containing a drug. These devices can be used as patches for local dermal applications releasing the drug in a controlled manner. The model active agent, lidocaine hydrochloride was chosen from the range of local anesthetics. When the drug is restricted to the surface, it is released more rapidly than when it is allowed to spread evenly throughout the silicon structure. When hydrophilic polymers such as PVA and HEC are mixed in with the lidocaine hydrochloride and deposited on the surface of the polymer matrix, we observed that the burst effect was eliminated without modifying the…
Granulomatous reactions from silicone: a diagnostic trap for the dermatophalogist.
2011
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
Microfabrication of hybrid fluid membrane for microengines
2015
International audience; This paper describes the microfabrication and dynamic characterization of thick membranes providing a technological solution for microengines. The studied membranes are called hybrid fluid-membrane (HFM) and consist of two thin membranes that encapsulate an incompressible fluid. This work details the microelectromechanical system (MEMS) scalable fabrication and characterization of HFMs. The membranes are composite structures based on Silicon spiral springs embedded in a polymer (RTV silicone). The anodic bonding of multiple stacks of Si/glass structures, the fluid filling and the sealing have been demonstrated. Various HFMs were successfully fabricated and their dyna…
Effect of head position on refraction in aphakic and phakic silicone-filled eyes.
1997
BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…
Deformation of bubbles in silicon gel insulation under an alternating electric field
2019
The behavior of silicone gel under electrical stress plays a significant role in the reliability and durability of high voltage electronic power devices due to its widespread use for the insulation of IGBT modules and other components. The charges accumulation at the bubble boundaries leads to significant displacements due to the establishment of Coulombic forces and the high deformability of colloidal system. The main purpose of this work is to validate a numerical approach useful to investigate, for a given silicone gel, the non-linear relation between the applied HVDC stress and the electric field over an air bubble within the insulation bulk. The analysis has been carried out by means o…
Tear Film Surface Quality in Modern Daily Disposable Contact Lens Wear
2021
Objectives As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. Methods Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluoresc…
A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates
2007
<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…
A Silicone Ventricular Catheter Coated with a Combination of Rifampin and Trimethoprim for the Prevention of Catheter-related Infections
1998
So-called antiinfective catheters which are generated by incorporation of antimicrobial substances into polymers appear to be effectful devices in the prevention of catheter related infections. Such devices mainly act by prevention of bacterial colonization of the catheter surface rather than by inhibition of adherence. In a preceding study, we developed a rifampin-containing silicone catheter for the prevention of ventricular shunt infection. In the present study, this work was continued with a combination of antimicrobials incorporated in silicone ventricular catheters to reduce the risk of rifampin resistance and to expand the antimicrobial spectrum. We found that the drug release kineti…
Rifampin-impregnated silicone catheters: a potential tool for prevention and treatment of CSF shunt infections.
2003
Background: Infection continues to be one of the major complications of cerebro-spinal fluid shunting procedures. Recent insights in the pathophysiological mechanism of these foreign body infections have elucidated the difficulty of achieving successful treatment without device removal. The development of a rifampin-impregnated silicone catheter yielded excellent results in infection prevention and treatment in vitro as well as in an animal model. Patients and Methods: Here, we describe the application of this device in two patients with a complicated course of shunt infection. Results: In one patient the rifampin-impregnated shunt system was implanted after external drainage to prevent fur…