Search results for "Silicones"

showing 10 items of 22 documents

Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields

1996

Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtyAdolescentgenetic structuresSiliconesOcular hypertensionGlaucomaSensitivity and SpecificityGoldmann applanation tonometryChemical disinfectionTonometry Ocularchemistry.chemical_compoundSiliconeDouble-Blind MethodOphthalmologymedicineHumansChildDisposable EquipmentIntraocular PressureAgedAged 80 and overAlternative methodsbusiness.industryReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologychemistryEvaluation Studies as TopicInfertilityFemaleOcular Hypertensionsense organsbusinessOphthalmology
researchProduct

Long-term results of the use of silicone sheets after diskectomy in the temporomandibular joint: clinical, radiographic and histopathologic findings

1999

The aim of the present study was to evaluate the long-term results of a group of patients who had the disk of the temporomandibular joint (TMJ) removed and permanently replaced by a silicone sheet. The study group comprised 48 patients, treated in the period from 1983 to 1993. In eight patients, the implants had to be removed after an average interval of 5.6 years and they were submitted for histopathological examination. Twenty-five of the 40 patients with silastic implants in place, and five of the 8 patients who had their implants removed, were available for long-term follow-up (mean interval of 7.0 years, SD 2.8 years). Clinical function was rated according to the Helkimo Dysfunction In…

AdultMalemedicine.medical_specialtyTime FactorsJoint ProsthesisRadiographySiliconesPalpationCondylechemistry.chemical_compoundSiliconeRadiography PanoramicTemporomandibular Joint DiscmedicineHumansDimethylpolysiloxanesDiskectomyDevice RemovalAgedChi-Square Distributionmedicine.diagnostic_testPolyethylene Terephthalatesbusiness.industryMiddle AgedSilasticProsthesis FailureTemporomandibular jointSurgerymedicine.anatomical_structureOtorhinolaryngologychemistryFemaleSurgeryHistopathologyOral SurgerybusinessFollow-Up StudiesInternational Journal of Oral and Maxillofacial Surgery
researchProduct

Pro-Inflammatory Cytokines in Elective Flap Surgery

2006

Surgical trauma releases inflammatory mediators such as pro-inflammatory cytokines. In this prospective, controlled, randomized trial we investigated the release of pro-inflammatory cytokines and monocyte/macrophage activation in patients scheduled for breast reconstruction after mastectomy. Patients were allocated to one of three surgical procedures, differing in complexity and in the need for implants used for reconstruction.Thirty mastectomized women underwent delayed breast reconstruction with the lateral thoracodorsal flap (LTD), the latissimus dorsi flap (LD), or the pedicled transverse rectus abdominis muscle flap (TRAM). Blood samples for TNF, IL-6, IL-8, neopterin, C-reactive prote…

Adultmedicine.medical_specialtyBreast ImplantsMammaplastymedicine.medical_treatmentSiliconesBreast NeoplasmsInflammationNeopterinSurgical FlapsProinflammatory cytokineLeukocyte Countchemistry.chemical_compoundHumansMedicineProspective StudiesSalineMastectomyAgedInterleukin-6Tumor Necrosis Factor-alphabusiness.industryInterleukin-8NeopterinMiddle AgedSurgeryPlastic surgeryC-Reactive ProteinCytokinechemistryCytokinesFemaleSurgerymedicine.symptombusinessBreast reconstructionBiomarkersMastectomyJournal of Surgical Research
researchProduct

Morphea after silicone gel breast implantation for cosmetic reasons in an HLA-B8,DR3-positive woman

1997

We describe an HLA-B8, DR3-positive patient with localized morphea after silicone gel breast implantation for cosmetic reasons. We believe that this case suggests that a genetic background, i.e. HLA-B8, DR3 haplotype, is involved in the autoimmune response to silicone.

Adultmusculoskeletal diseasesmedicine.medical_specialtyBreast implantationBreast ImplantsMammaplastyImmunologyMammary glandCD4-CD8 RatioSiliconesHLA-B8 AntigenScleroderma Localizedchemistry.chemical_compoundHLA-DR3 AntigenSiliconeLocalized morpheamedicineHumansImmunology and AllergySurgery Plasticskin and connective tissue diseasesGlucocorticoidsbusiness.industrytechnology industry and agricultureGeneral Medicinemedicine.diseaseConnective tissue diseaseSurgeryPlastic surgerymedicine.anatomical_structurechemistryImmunologyPrednisoneFemalebusinessMorpheaCircumscribed scleroderma
researchProduct

Polylactic is a Sustainable, Low Absorption, Low Autofluorescence Alternative to Other Plastics for Microfluidic and Organ-on-Chip Applications

2020

Organ-on-chip (OOC) devices are miniaturized devices replacing animal models in drug discovery and toxicology studies. The majority of OOC devices are made from polydimethylsiloxane (PDMS), an elastomer widely used in microfluidic prototyping, but posing a number of challenges to experimentalists, including leaching of uncured oligomers and uncontrolled absorption of small compounds. Here we assess the suitability of polylactic acid (PLA) as a replacement material to PDMS for microfluidic cell culture and OOC applications. We changed the wettability of PLA substrates and demonstrated the functionalization method to be stable over a time period of at least 9 months. We successfully cultured …

BiocompatibilityPolydimethylsiloxane010401 analytical chemistryMicrofluidicstechnology industry and agricultureSettore ING-IND/34 - Bioingegneria IndustrialeNanotechnologymacromolecular substancesengineering.material010402 general chemistryElastomerSettore ING-INF/0701 natural sciences0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundAutofluorescenceCoatingPolylactic acidchemistryBiocompatibility Cell culture Diseases Elastomers Microchannels Microfluidics Polydimethylsiloxane Silicones TransparencyengineeringSurface modificationAnalytical Chemistry
researchProduct

Material properties of various intraocular lenses in an experimental study.

2002

<i>Introduction:</i> With the recent introduction of small-incision cataract surgery, requirements for intraocular lens (IOL) flexibility, strength and hydrophilicity have rapidly evolved. The IOL surface, however, remains a critical factor influencing uveal biocompatibility. <i>Purpose:</i> To objectively quantify factors of material properties of various IOLs using contact angle measurements, differential scanning calorimetry, dynamic-mechanical measurements and scanning electron microscopy. <i>Material and Methods:</i> In our study, 17 currently available IOLs were investigated using contact angle measurements to assess hydrophilicity and biocompatibil…

Flexibility (engineering)Lenses Intraocularmedicine.medical_specialtygenetic structuresCalorimetry Differential ScanningComputer sciencemedicine.medical_treatmentSiliconesIntraocular lensGeneral MedicineEquipment DesignCataract surgeryeye diseasesSensory SystemsElasticityHydrogel Polyethylene Glycol DimethacrylateOphthalmologyIntraocular lensesAcrylatesOphthalmologymedicineMicroscopy Electron ScanningHumanssense organsOphthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde
researchProduct

Improved method for cannula fixation for long-term intracerebral brain infusion

2017

Abstract Background Implanted osmotic minipumps are commonly used for long-term, brain-targeted delivery of a wide range of experimental agents by being connected to a catheter and a cannula. During the stereotactical surgery procedure, the cannula has to be placed correctly in the x-y directions and also with respect to the injection point in the z-direction (deepness). However, the flat fixation base of available cannula holders doesn’t allow an easy, secure fixation onto the curve-shaped skull. New method We have developed a modified method for a better fixation of the cannula holder by using an easy-to-produce, skull-shaped silicone spacer as fixation adapter. Results We describe the ap…

Male0301 basic medicinemedicine.medical_specialtySiliconesModified methodImproved methodBrain tissueMice03 medical and health sciencesFixation (surgical)Drug Delivery SystemsImaging Three-Dimensional0302 clinical medicineSurgery procedureSkull surfacemedicineAnimalsCannulabusiness.industryGeneral NeuroscienceBrainInfusion Pumps ImplantableCannulaSurgeryMice Inbred C57BLCatheter030104 developmental biologyTomography X-Ray Computedbusiness030217 neurology & neurosurgeryJournal of Neuroscience Methods
researchProduct

A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates

2007

<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…

Malemedicine.medical_specialtySiliconesPostoperative ComplicationsClivusmedicineAnimalsMinimally Invasive Surgical ProceduresBase (exponentiation)Cerebrospinal FluidSkull BaseCerebrospinal Fluid Leakagebusiness.industryForeign-Body ReactionSilicone plugEndoscopyProstheses and ImplantsLong term resultsPlastic Surgery ProceduresAnti-Bacterial AgentsSurgerySkullmedicine.anatomical_structureModels AnimalSkull base surgeryInvasive surgeryPapio hamadryasSurgerybusinessEuropean Surgical Research
researchProduct

Submicrometer-Sized Roughness Suppresses Bacteria Adhesion.

2020

Biofilm formation is most commonly combatted with antibiotics or biocides. However, proven toxicity and increasing resistance of bacteria increase the need for alternative strategies to prevent adhesion of bacteria to surfaces. Chemical modification of the surfaces by tethering of functional polymer brushes or films provides a route toward antifouling coatings. Furthermore, nanorough or superhydrophobic surfaces can delay biofilm formation. Here we show that submicrometer-sized roughness can outweigh surface chemistry by testing the adhesion of E. coli to surfaces of different topography and wettability over long exposure times (>7 days). Gram-negative and positive bacterial strains are tes…

Materials scienceHydrocarbons FluorinatedBiofoulingSilicones02 engineering and technologyengineering.material010402 general chemistryPseudomonas fluorescens01 natural sciencesBacterial Adhesionsilicone nanofilamentsBiofoulingchemistry.chemical_compoundSiliconeCoatingForum ArticleEscherichia coliGeneral Materials ScienceroughnessbiologyantifoulingBiofilmAdhesion021001 nanoscience & nanotechnologybiology.organism_classification0104 chemical sciencesNanostructuresMicrococcus luteusbacterial sizeChemical engineeringchemistryengineeringWettabilityWettingGlass0210 nano-technologyLayer (electronics)BacteriaACS applied materialsinterfaces
researchProduct

Microstructuring of phospholipid bilayers on gold surfaces by micromolding in capillaries

2005

Microstructuring of lipid bilayers on gold surfaces was achieved by micromolding in capillaries employing chemically modified polydimethylsiloxane (PDMS). Microfluidic networks of PDMS were prepared by micromolding and functionalized with thiol end-groups using 3-mercaptopropyltrimethoxysilane. The PDMS stamps were firmly attached to the gold substrate via quasi-covalent linkage providing a tight seal, a prerequisite for establishing individual addressable capillaries. Bilayers composed of POPC/POPG were subsequently prepared on microstructured self assembly monolayers of 11-amino-1-undecanethiol via strong electrostatic interactions. This way it is possible to generate individually address…

Materials sciencePolydimethylsiloxaneLipid BilayersMicrofluidicsMicrofluidicsSiliconestechnology industry and agriculturePDMS stampNanotechnologyMicroscopy Atomic ForceSoft lithographySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsBiomaterialschemistry.chemical_compoundColloid and Surface ChemistrychemistryMonolayerDimethylpolysiloxanesGoldSelf-assemblyLipid bilayerPOPCPhospholipidsJournal of Colloid and Interface Science
researchProduct