Genotoxicity of citrus wastewater in prokaryotic and eukaryotic cells and efficiency of heterogeneous photocatalysis by TiO(2).

2012

Abstract The presence of (±)α-pinene, (+)β-pinene, (+)3-carene, and R-(+)limonene terpenes in wastewater of a citrus transformation factory was detected and analyzed, in a previous study, by using Solid Phase Micro-extraction (SPME) followed by GC analyses. Purpose of that research was to compare the genotoxic responses of mixtures of terpenes with the genotoxicity of the individual compounds, and the biological effects of actual wastewater. Genotoxicity was evaluated in the Salmonella reversion assay (Ames test) and in V79 cells by Comet assay. Ames tests indicated that the four single terpenes did not induce an increase of revertants frequency. On the contrary, the mixtures of terpenes ca…

CitrusChromatography GasDNA damageBiophysicsPHOTOCATALYSIS TiO2 GENOTOXICITYmedicine.disease_causeWaste Disposal FluidCatalysisAmes testCell LineTerpenechemistry.chemical_compoundBridged Bicyclo CompoundsCricetulusCricetinaeCyclohexenesmedicineAnimalsRadiology Nuclear Medicine and imagingSolid Phase MicroextractionBicyclic MonoterpenesTitaniumLimoneneRadiationChromatographyPhotolysisRadiological and Ultrasound TechnologyMutagenicity TestsTerpenesComet assayTransformation (genetics)chemistryWastewaterEnvironmental chemistryMonoterpenesSettore CHIM/07 - Fondamenti Chimici Delle TecnologieComet AssayGenotoxicityLimoneneWater Pollutants ChemicalDNA DamageJournal of photochemistry and photobiology. B, Biology
researchProduct

On-line analysis of carbonyl compounds with derivatization in aqueous extracts of atmospheric particulate PM10 by in-tube solid-phase microextraction…

2011

Abstract A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl–5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analys…

Detection limitAldehydesAqueous solutionChromatographyCapillary actionOrganic ChemistryReproducibility of ResultsGeneral MedicineParticulatesReference StandardsSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical ChemistryAcetonechemistry.chemical_compoundchemistryCapillary columnTube (fluid conveyance)Particulate MatterParticle SizeDerivatizationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

2013

Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including prac…

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryGeneral MedicineSolid-phase microextractionBiochemistryAnalytical ChemistryMeasuring instrumentSample preparationSample collectionSolid phase extractionSolid Phase MicroextractionJournal of chromatography. A
researchProduct

New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…

2008

Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryReproducibility of ResultsGeneral MedicineReference StandardsSolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBivalviaMatrix (chemical analysis)AnimalsSample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…

2011

Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…

Detection limitAnalyteChromatographyMonolithic HPLC columnTriazinesCapillary actionPhenylurea CompoundsOrganic ChemistryDinitroanilineAnalytical chemistryReproducibility of ResultsContext (language use)General MedicineSolid-phase microextractionSensitivity and SpecificityBiochemistryAnalytical Chemistrychemistry.chemical_compoundOrganophosphorus CompoundschemistryChromatography columnSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Improving analysis of apolar organic compounds by the use of a capillary titania-based column: Application to the direct determination of faecal ster…

2010

This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic prof…

Detection limitAnalyteChromatographySewageChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographySolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryCoprostanolCholestanolchemistry.chemical_compoundFecesCholesterolWastewaterHumansSample preparationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case.

2020

Abstract Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and o…

Detection limitAnalyteEnvironmental EngineeringChromatographyMaterials science010504 meteorology & atmospheric sciencesResolution (mass spectrometry)Capillary action010501 environmental sciences01 natural sciencesPollutionDiode arrayNano liquid chromatographyTheophyllineLimit of DetectionCaffeineEnvironmental ChemistryFigure of meritSolid phase extractionWaste Management and DisposalChromatography High Pressure LiquidSolid Phase MicroextractionWater Pollutants Chemical0105 earth and related environmental sciencesChromatography LiquidThe Science of the total environment
researchProduct

Miniaturized matrix solid phase dispersion procedure and solid phase microextraction for the analysis of organochlorinated pesticides and polybromina…

2009

Abstract This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and acetonitrile–water as eluting solvent for the analysis of legislated organochlorinated pesticides (OCPs) and polybrominated diphenylethers (PBDEs) in biota samples by GC with electron capture (GC-ECD). The method has compared Florisil®-acidic Silica and C18 as dispersant for samples as well as different solvents. Recovery studies showed that the combination of C18–Florisil® was better when using low amount of samples (0.1 g) and with low volumes of acetonitrile–water (2.6 mL). The use of SPME for extracting the analytes from the solvent mixture before the injectio…

Detection limitChromatography GasChromatographyChemistryOrganic ChemistryPesticide ResiduesAnalytical chemistryGeneral MedicineSolid-phase microextractionBiochemistryDispersantBivalviaAnalytical ChemistrySolventElectron capture detectorHalogenated Diphenyl EthersHydrocarbons ChlorinatedAnimalsSample preparationSolid phase extractionGas chromatographyFood AnalysisSolid Phase MicroextractionJournal of Chromatography A
researchProduct

On-line in-tube solid phase microextraction-capillary liquid chromatography method for monitoring degradation products of di-(2-ethylhexyl) phthalate…

2014

Abstract The main di-(2-ethylhexyl) phthalate (DEHP) degradation products, (2-ethylhexyl) phthalate (MEHP), diethyl phthalate (DEP) and dibutyl phthalate (DBP), have been tested. The proposed cost-effective method combines on-line, in-tube solid-phase micro extraction (IT-SPME) in in-valve configuration and capillary liquid chromatography with UV diode array detection (Cap-LC-DAD). Acidification of the samples at pH 3 improved markedly the estimation of MEHP. Aliquots of 4 mL of acidified water samples were directly processed. After sample loading, the analytes were desorbed with the mobile-phase and transferred to the monolithic capillary column. Satisfactory linearity and precision, absen…

Detection limitChromatographyChemistryDibutyl phthalateCapillary actionOrganic ChemistryExtraction (chemistry)Phthalic AcidsPhthalateGeneral MedicineSolid-phase microextractionDiethyl phthalateBiochemistryDibutyl PhthalateAnalytical Chemistrychemistry.chemical_compoundPlasticizersDiethylhexyl PhthalateSample preparationSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine i…

2009

The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…

Detection limitChromatographyMonolithic HPLC columnPolydimethylsiloxaneCapillary actionPolymersCationic polymerizationSolid-phase microextractionEthylenediaminesAnalytical Chemistrychemistry.chemical_compoundchemistryChemical IndustryIndicators and ReagentsDerivatizationDimethylamineSolid Phase MicroextractionChromatography LiquidAnalytical chemistry
researchProduct