Search results for "Specificity."

showing 10 items of 2232 documents

CEUS in the differential diagnosis between biliary sludge, benign lesions and malignant lesions

2017

Abstract PURPOSE: Conventional grayscale ultrasound (US) is accurate in the diagnosis of gallbladder disease (GD), but in some cases, it is not decisive. Contrast-enhanced ultrasound (CEUS) improves the diagnostic accuracy of US. The primary objective of this study is to assess the reliability of CEUS in the diagnosis of sludge; the secondary objective is to assess the ability of CEUS to diagnose cancer. METHODS: We retrospectively reviewed the US of 4137 patients positive for GD. In 43/4137 (1.04%), the use of could not discriminate between sludge and neoplasms. Then, we evaluated CEUS in only 39 of these patients, and in 4/43 (9%) cases it was not performable. After CEUS, the absence of e…

AdultMalemedicine.medical_specialtySettore MED/09 - Medicina InternaGallbladder diseaseContrast MediaGallbladder DiseasesMalignancySensitivity and SpecificitySludge030218 nuclear medicine & medical imagingDiagnosis Differential03 medical and health sciences0302 clinical medicineUltrasoundInternal MedicinemedicineBileHumansRadiology Nuclear Medicine and imagingBiliary sludgeMalignant diseaseAgedRetrospective StudiesUltrasonographybusiness.industryGallbladderCarcinomaUltrasoundBenign diseaseReproducibility of ResultsGallbladderWashoutCancerGeneral MedicineMiddle Agedmedicine.diseasemedicine.anatomical_structure030220 oncology & carcinogenesisCEUSFemaleOriginal ArticleRadiologyDifferential diagnosisbusinessJournal of Ultrasound
researchProduct

Electrical impedance spectroscopy as a potential adjunct diagnostic tool for cutaneous melanoma.

2012

Background Previous studies have shown statistically significant differences in electrical impedance between various cutaneous lesions. Electrical impedance spectroscopy (EIS) may therefore be able to aid clinicians in differentiating between benign and malignant skin lesions. Objectives The aim of the study was to develop a classification algorithm to distinguish between melanoma and benign lesions of the skin with a sensitivity of at least 98% and a specificity approximately 20 per cent higher than the diagnostic accuracy of dermatologists. Patients/Methods A total of 1300 lesions were collected in a multicentre, prospective, non-randomized clinical trial from 19 centres around Europe. Al…

AdultMalemedicine.medical_specialtySkin NeoplasmsAdolescentDermatologySensitivity and SpecificityYoung AdultmedicineAtypiaPrevalenceHumansDiagnosis Computer-AssistedElectrical impedance spectroscopyMelanomaAgedAged 80 and overbusiness.industryMelanomaReproducibility of ResultsMiddle Agedmedicine.diseaseDermatologyClinical trialEuropeDielectric SpectroscopyCutaneous melanomaDysplastic nevusFeasibility StudiesFemaleSkin cancerbusinessSkin lesionAlgorithmsSkin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)
researchProduct

Clinical performance of the Nevisense system in cutaneous melanoma detection: an international, multicentre, prospective and blinded clinical trial o…

2014

Summary Background Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. Objectives To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. Methods This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were exami…

AdultMalemedicine.medical_specialtySkin NeoplasmsAdolescentMedizinDermoscopyDermatologySensitivity and SpecificityBreslow ThicknessYoung AdultPositive predicative valueBiopsymedicineElectric ImpedancePhotographyHumansddc:610Prospective StudiesProspective cohort studyMelanomaEarly Detection of CancerAgedAged 80 and overmedicine.diagnostic_testbusiness.industryMelanomaOriginal ArticlesMiddle Agedmedicine.diseaseDermatologySurgeryClinical trialCarcinoma Basal CellDielectric SpectroscopyCutaneous melanomaCarcinoma Squamous CellFemalePatient SafetySkin cancerbusinessThe British journal of dermatology
researchProduct

The Usefulness of Dermoscopy for the Recognition of Malignant Collision Tumors.

2021

<b><i>Background:</i></b> Preoperative diagnosis of malignant collision tumors (MCT) is extremely difficult. The value of dermoscopy to improve the correct detection of these tumors has not been previously studied. This study aims to evaluate the diagnostic accuracy of MCT with and without dermoscopy and to describe the dermoscopic features of a large series of MCT. <b><i>Methods:</i></b> Dermoscopic images of 161 MCT were evaluated. Clinical and dermoscopic images of histopathologically proven MCT intermingled with other tumors were randomly presented to clinicians with different levels of experience, blinded to the diagnosis and objective of…

AdultMalemedicine.medical_specialtySkin NeoplasmsKeratosisDiagnostic accuracyDermoscopyDermatologySensitivity and SpecificityDiagnosis DifferentialYoung AdultSquamous cell carcinomaMedicineNevusHumansCollision tumorBasal cellBasal cell carcinomaMedical diagnosisKeratosis SeborrheicMelanomaPhysical ExaminationAgedAged 80 and overNevus Pigmentedbusiness.industryMelanomaLarge seriesMiddle Agedmedicine.diseaseCarcinoma Basal CellBasal cell carcinomaFemaleCollision tumorsRadiologybusinessDermatology (Basel, Switzerland)
researchProduct

Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally m…

2006

A causal approach to the calculation of coherence and transfer function between systolic pressure (SP) and RR interval variability was applied in eight patients and eight control subjects during prolonged tilt test for investigating the impairment of cardiovascular control related to neurally mediated syncope. The causal analysis showed a depressed baroreflex regulation in resting patients, with reduced gain and increased latency from SP to RR, and a drop of the baroreflex coupling immediately before syncope. These findings, which were not elicited by traditional cross-spectral analysis, strongly suggest the use of the causal approach for the study of syncope mechanisms. © 2006 IEEE.

AdultMalemedicine.medical_specialtyStatistics as TopicBiomedical EngineeringBlood PressureNeurally-mediated syncopeCardiovascular controlBaroreflexCardiovascular SystemSensitivity and SpecificitySeverity of Illness IndexFeedbackElectrocardiographyHeart RateInternal medicineSeverity of illnessHeart rateSyncope VasovagalmedicineHumansComputer SimulationDiagnosis Computer-AssistedModels Statisticalmedicine.diagnostic_testbusiness.industryTransfer functionModels CardiovascularReproducibility of ResultsBaroreflexBlood pressureData Interpretation StatisticalAnesthesiaCardiologyRegression AnalysisFemalebusinessElectrocardiographyCoherenceAlgorithmsSyncope (phonology)
researchProduct

Measuring postural-related changes of spontaneous baroreflex sensitivity after repeated long-duration diving: Frequency domain approaches

2012

Sustained water immersion is thought to modulate orthostatic tolerance to an extent dependent on the duration and repetition over consecutive days of the diving sessions. We tested this hypothesis investigating in ten healthy subjects the potential changes in the cardiovascular response to head-up tilt induced by single and multiple resting air dives. Parametric cross-spectral analysis of spontaneous RR interval and systolic arterial pressure variability was performed in three experimental sessions: before diving (BD), after single 6-hour dive (ASD), and after multiple 6-hour dives (AMD, 5 consecutive days with 18-hour surface interval). From this analysis, baroreflex sensitivity (BRS) was …

AdultMalemedicine.medical_specialtySupine positionDivingPostureRR intervalOrthostatic intoleranceBaroreflexSensitivity and SpecificityEndocrine and Autonomic SystemCellular and Molecular NeuroscienceOrthostatic vital signsInternal medicinemedicineHumansShort durationAnalysis of VarianceElectronic Data ProcessingEndocrine and Autonomic Systemsbusiness.industrySpectrum AnalysisHead-up tiltBaroreflexCardiovascular variabilitymedicine.diseaseCausal coherenceParametric cross-spectral analysiFrequency domainSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPower ratioCardiologyNeurology (clinical)businessOrthostatic toleranceAutonomic Neuroscience
researchProduct

Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure

2011

We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…

AdultMalemedicine.medical_specialtySystoleDiastolePulse transit timeSphygmomanometerSensitivity and SpecificityQRS complexDiastoleInternal medicineValidationmedicineHumansDiagnosis Computer-AssistedSystolePhotoplethysmographyAccuracyAgedbusiness.industryReproducibility of ResultsBlood Pressure DeterminationEquipment DesignMiddle AgedSphygmomanometersConfidence intervalSurgeryBlood pressure monitoringEquipment Failure AnalysisBlood pressurePulsatile FlowCuffSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaElectrocardiography AmbulatoryCardiologyNoninvasive measurementFeasibility StudiesArterial bloodFemalebusinessCardiology and Cardiovascular Medicine
researchProduct

Advantages of immediate two-dimensional echocardiography in patients with acute cardiac ischemic events

1995

Abstract We hypothesized that the assessment of kinetic alterations on two dimensional echocardiogram (2DE) would provide greater diagnostic information than clinical symptoms and ECG changes only. The study was aimed to determine sensitivity of 2DE in patients with cardiac ischemic events and to improve the indications to thrombolysis. Three-hundred ninety-one patients (87 F; 304 M) hospitalized for suspected acute myocardial infarction (AMI), first episode, within 4 h from the onset of symptoms, suitable for thrombolysis Killip class I–II and with unstable angina (UA), were admitted in the study. Patients had to show ECG changes and alterations of segmentary motion on 2DE performed at ent…

AdultMalemedicine.medical_specialtySystolemedicine.medical_treatmentMyocardial InfarctionMyocardial IschemiaIschemiaInfarctionSensitivity and SpecificityVentricular Function LeftElectrocardiographyFibrinolytic AgentsInternal medicinemedicineHumansThrombolytic TherapyAngina Unstablecardiovascular diseasesMyocardial infarctionAngioplasty Balloon CoronaryCoronary Artery BypassCreatine KinaseAgedKillip classAged 80 and overFirst episodeHeparinVascular diseaseUnstable anginabusiness.industryThrombolysisMiddle Agedmedicine.diseaseIsoenzymesSurvival RateEchocardiographyVentricular Function RightCardiologyFemaleCardiology and Cardiovascular MedicinebusinessInternational Journal of Cardiology
researchProduct

Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial Experiences

2003

Purpose To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T (2)-weighted TSE with and w…

AdultMalemedicine.medical_specialtyTime FactorsAdolescentImage qualityKnee InjuriesSensitivity and SpecificityFractures BoneMusculoskeletal disordermedicineHumansRadiology Nuclear Medicine and imagingDetection theoryAnkle InjuriesChildAgedSensitivity encodingAged 80 and overMusculoskeletal imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFemoral Neck FracturesSurgerymedicine.anatomical_structureElectromagnetic coilFeasibility StudiesFemaleAnklebusinessAlgorithmsHip InjuriesBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers

2002

WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …

AdultMalemedicine.medical_specialtyTime FactorsAtrial sensingSensitivity and SpecificityPacemaker systemElectrocardiographyIntraoperative fluoroscopyInternal medicineHumansMulticenter Studies as TopicMedicineHeart Atriacardiovascular diseasesAgedRetrospective StudiesAged 80 and overbusiness.industryP waveCardiac Pacing ArtificialEquipment DesignGeneral MedicineMiddle AgedDipoleHeart Blockmedicine.anatomical_structureSingle leadAtrioventricular Nodecardiovascular systemCardiologyRight atriumEquipment FailureFemaleCardiology and Cardiovascular MedicinebusinessHolter monitoringFollow-Up StudiesPacing and Clinical Electrophysiology
researchProduct