Search results for "Specificity."

showing 10 items of 2232 documents

Multiple-stage mass spectrometric analysis of six pesticides in oranges by liquid chromatography–atmospheric pressure chemical ionization–ion trap ma…

2004

Abstract Six pesticides were determined by liquid chromatography (LC) with positive ion (PI) atmospheric pressure chemical ionization quadrupole ion-trap tandem mass spectrometry (APCI–MS–MS). Ion fragmentation was studied by MS, MS 2 and MS 3 . Fragmentation of the pesticides produced ions formed by various losses from the side-chains and through heterocyclic ring opening, but without any common fragmentation pathway. Multiple reaction monitoring (MRM) of MS, MS 2 and MS 3 was used to identify and quantify the pesticides. The samples were extracted with ethyl acetate and dried over anhydrous sodium sulfate. Comparison of the three MS modes showed that MS 3 is slightly less sensitive but mu…

Detection limitChemical ionizationChromatographyChemistryOrganic ChemistrySelected reaction monitoringAnalytical chemistryReproducibility of ResultsAtmospheric-pressure chemical ionizationGeneral MedicineTandem mass spectrometryMass spectrometrySensitivity and SpecificityBiochemistryMass SpectrometryAnalytical ChemistryAtmospheric PressureIon trapPesticidesQuadrupole ion trapChromatography LiquidCitrus sinensisJournal of Chromatography A
researchProduct

Determination of carbamate residues in fruits and vegetables by matrix solid-phase dispersion and liquid chromatography-mass spectrometry.

2000

Abstract Thirteen carbamates were analysed in orange, grape, onion and tomatoes by matrix solid-phase dispersion (MSPD) followed by liquid chromatography–mass spectrometry (LC–MS). Electrospray (ES) and atmospheric pressure chemical ionisation (APCI) were compared and both gave similar results in terms of sensitivity and structural information because at 20 V fragmentor voltages the fragmentation is minimal. The efficiency of different solid-phases (C18, C8, cyano, amine and phenyl) for the MSPD was compared. Mean recoveries using C8 varied from 64 to 106% with relative standard deviations of 5–15% in the concentration range of 0.01–10 mg kg−1. Matrix constituents did not interfere signific…

Detection limitChemical ionizationInsecticidesChromatographyChemistryOrganic ChemistryPesticide ResiduesAtmospheric-pressure chemical ionizationGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometryFruitVegetablesmedia_common.cataloged_instanceSolid phase extractionCarbamatesEuropean unionChromatography High Pressure Liquidmedia_commonJournal of chromatography. A
researchProduct

Analysis of organophosphorus pesticides in honeybee by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

2001

Pesticides applied in extended agricultural fields may be controlled by means of bioindicators, such as honeybees, in which are the pesticides bioaccumulate. Liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) experiments with positive (PI) and negative (NI) ion modes were optimized for the analysis of 22 organophosphorus pesticides in honeybee samples. The extraction required 3 g of sample, which was extracted with acetone. The extract was purified with coagulating solution and reextracted with Cl(2)CH(2). Pesticides studied could be detected by both ionization modes except for parathion, parathion-methyl, and bromophos, which did not give signals …

Detection limitChemical ionizationInsecticidesChromatographyExtraction (chemistry)Analytical chemistryPesticide ResiduesAtmospheric-pressure chemical ionizationGeneral ChemistryPesticideBeesMass spectrometrySensitivity and SpecificityMass Spectrometrychemistry.chemical_compoundParathionOrganophosphorus CompoundschemistryAnimalsSelected ion monitoringGeneral Agricultural and Biological SciencesChromatography LiquidJournal of agricultural and food chemistry
researchProduct

2,4,6-Triphenylpyrylium Ion Encapsulated into Zeolite Y as a Selective Electrode for the Electrochemical Determination of Dopamine in the Presence of…

2002

2,4,6-Triphenylpyrylium ion immobilized inside the supercages of zeolite Y enhances by 1-2 orders of magnitude the response of electrochemical oxidation of dopamine in neutral aqueous media accompanied by a remarkable inhibition of post-electron-transfer reactions. The negative charge of the zeolite framework in which the 2,4,6-triphenylpyrylium ion is incorporated blocks the electrochemical oxidation of the negative ascorbate ion, enabling the determination of micromolar concentrations of dopamine in the presence of a large excess (10(3)-10(4) times) of ascorbate in phosphate buffer (pH 7.4). Under optimized conditions, linear calibration plots were obtained for a differential pulse detect…

Detection limitChemistryDopamineInorganic chemistryAscorbic AcidElectrochemistryAscorbic acidSensitivity and SpecificityOrders of magnitude (mass)Analytical ChemistryIonDopamineCalibrationElectrodeElectrochemistryZeolitesmedicineZeoliteElectrodesOxidation-ReductionPyransmedicine.drugAnalytical Chemistry
researchProduct

Fishing for a drug: solid-phase microextraction for the assay of clozapine in human plasma

1999

Solid-phase microextraction (SPME) was investigated as a sample preparation method for assaying the neuroleptic drug clozapine in human plasma. A mixture of human plasma, water, loxapine (as internal standard) and aqueous NaOH was extracted with a 100-micron polydimethylsiloxane (PDMS) fiber (Supelco). Desorption of the fiber was performed in the injection port of a gas chromatograph at 260 degrees C (HP 5890; 30 m x 0.53 mm I.D., 1 micron film capillary; nitrogen-phosphorous selective detection). Fibers were used repeatedly in up to about 75 analyses. The recovery was found to be 3% for clozapine from plasma after 30 min of extraction. However, in spite of the low recovery, the analyte was…

Detection limitChromatography GasChromatographymedicine.diagnostic_testChemistryReproducibility of ResultsLoxapineGeneral ChemistryReference StandardsSolid-phase microextractionSensitivity and SpecificityHigh-performance liquid chromatographyMatrix (chemical analysis)Therapeutic drug monitoringmedicineHumansSample preparationSolid phase extractionGas chromatographyClozapineJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Determination of water-soluble UV-filters in sunscreen sprays by liquid chromatography.

2002

Abstract Liquid chromatography was used for the determination of the three most used water-soluble UV filters, benzophenone-4 (BZ4), terephthalylidene dicamphor sulfonic acid (TDS), and phenylbenzimidazole sulphonic acid (PBS), in aqueous sunscreen sprays. A C 18 stationary phase and an isocratic mobile phase of EtOH–20 m M sodium acetate buffer of pH 4.6 (30:70, v/v) were used at a flow-rate of 0.5 ml min −1 . Mobile phase was also used as solvent for samples and standards. UV detection was at 313 nm. The analytical run took 5.5 min. The limits of detection were 0.5, 0.9 and 2 μg ml −1 for BZ4, TDS and PBS, respectively. The proposed method does not involve highly toxic solvents.

Detection limitChromatographyAqueous solutionChemistryUltraviolet RaysOrganic ChemistryGeneral MedicineReversed-phase chromatographySulisobenzoneReference StandardsBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistrySolventchemistry.chemical_compoundPhase (matter)Spectrophotometry UltravioletSodium acetateSunscreening AgentsChromatography LiquidJournal of chromatography. A
researchProduct

Automatic in-tube SPME and fast liquid chromatography: A cost-effective method for the estimation of dibuthyl and di-2-ethylhexyl phthalates in envir…

2007

A 80-cm length commercially available capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane (TBR-5) was employed to carry out on-line extraction and preconcentration of dibuthyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) in the chromatographic system. The coated capillary was placed between the sample injection loop and the injection needle of an autosampler. Variables affecting the automatic in-tube solid-phase microextraction (SPME) were optimized. A Genesis C(18) (5 cm x 4.6 mm i.d., 4 microm particle size) was employed as analytical column. The achieved limits of detection by use of diode array detection were 1 and 2.5 microg L(-1), respectively. The propo…

Detection limitChromatographyCapillary actionCost-Benefit AnalysisCoefficient of variationExtraction (chemistry)PhthalateAnalytical chemistryReproducibility of ResultsSolid-phase microextractionSensitivity and SpecificityBiochemistryDibutyl PhthalateAnalytical Chemistrychemistry.chemical_compoundchemistryDiethylhexyl PhthalateEnvironmental ChemistrySample preparationParticle sizeWater Pollutants ChemicalSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of uranium in tap water by ICP-MS

2000

A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%…

Detection limitChromatographyChemistryAnalytical chemistryReproducibility of Resultschemistry.chemical_elementRepeatabilityIsotope dilutionUraniumSensitivity and SpecificityBiochemistryMass SpectrometryMoroccoMineral waterTap waterMetalsSpainWater SupplyUraniumInductively coupled plasmaInductively coupled plasma mass spectrometryFresenius' Journal of Analytical Chemistry
researchProduct

Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…

2001

An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…

Detection limitChromatographyChemistryMetaboliteReproducibility of ResultsGeneral ChemistryPirenzepineHigh-performance liquid chromatographySensitivity and SpecificityAcetic acidchemistry.chemical_compoundBenzodiazepinesAdsorptionPharmacokineticsOlanzapinemedicineHumansSpectrophotometry UltravioletQuantitative analysis (chemistry)ClozapineClozapineChromatography High Pressure Liquidmedicine.drugAntipsychotic AgentsJournal of chromatography. B, Biomedical sciences and applications
researchProduct

High-performance liquid chromatographic determination of tocopherols in infant formulas

2002

A method for the simultaneous determination of alpha-tocopherol acetate and alpha-, delta-, and gamma-tocopherols by normal-phase high-performance liquid chromatography (HPLC) with a fluorescent detector in infant formula is proposed. The values obtained in the determination of the analytical parameters: linearity, precision, limit of detection and accuracy (analysis of a standard reference material, SRM 1846), confirm the quality of the method. The proposed method is useful for the determination of alpha-, delta-, and gamma-tocopherols and alpha-tocopherol acetate in infant formulas at a low cost and in a total time of 2 h.

Detection limitChromatographyChemistryVitamine eOrganic ChemistryDetectorAnalytical chemistryInfantReproducibility of ResultsTocopherolsfood and beveragesLinearityGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrometry FluorescenceHumansInfant FoodQuantitative analysis (chemistry)Chromatography High Pressure LiquidAnalysis methodJournal of Chromatography A
researchProduct