Search results for "Spectral"

showing 10 items of 3116 documents

Pulsed EPR determination of water accessibility to spin-labeled amino acid residues in LHCIIb.

2009

Membrane proteins reside in a structured environment in which some of their residues are accessible to water, some are in contact with alkyl chains of lipid molecules, and some are buried in the protein. Water accessibility of residues may change during folding or function-related structural dynamics. Several techniques based on the combination of pulsed electron paramagnetic resonance (EPR) with site-directed spin labeling can be used to quantify such water accessibility. Accessibility parameters for different residues in major plant light-harvesting complex IIb are determined by electron spin echo envelope modulation spectroscopy in the presence of deuterated water, deuterium contrast in …

DetergentsBiophysicsLight-Harvesting Protein ComplexesSpectroscopy Imaging and Other TechniquesBuffersCrystallography X-RaySpectral linelaw.inventionlawMoleculeHumansAmino AcidsElectron paramagnetic resonanceProtein Structure QuaternaryHyperfine structureAlkylPlant Proteinschemistry.chemical_classificationPulsed EPRChemistryElectron Spin Resonance SpectroscopyPeasTemperatureWaterSite-directed spin labelingCrystallographyDeuteriumSolubilityMutationSolventsSpin LabelsProtein MultimerizationBiophysical journal
researchProduct

On the Consistent Use of VaR in Portfolio Performance Evaluation: A Cautionary Note

2010

The portfolio performance measures based on the Value-at-Risk (VaR) concept have gained widespread popularity and are often used in empirical studies. Unfortunately, we have noticed that in majority of empirical studies a VaR-based performance measure is used inconsistently. The goal of this paper is, therefore, to emphasize how to consistently use VaR in portfolio performance evaluation. We also elaborate on a simple framework that allows to derive a general formula for a portfolio performance measure which is not limited to the use of VaR-based reward and risk measures, but is valid for all reward and risk measures that satisfy a few plausible properties.

Deviation risk measureExpected shortfallActuarial scienceSpectral risk measureCoherent risk measureDistortion risk measureEconomicsPortfolioPost-modern portfolio theoryPortfolio optimizationSSRN Electronic Journal
researchProduct

Towards noncontact skin melanoma selection by multispectral imaging analysis

2011

A clinical trial comprising 334 pigmented and vascular lesions has been performed in three Riga clinics by means of multispectral imaging analysis. The imaging system Nuance 2.4 (CRi) and self-developed software for mapping of the main skin chromophores were used. Spe- cific features were observed and analyzed for malignant skin melanomas: notably higher absorbance (especially as the difference of optical density relative to the healthy skin), uneven chromophore distribution over the lesion area, and the possibility to select the "melanoma areas" in the correla- tion graphs of chromophores. The obtained results indicate clinical potential of this technology for noncontact selec- tion of mel…

Diagnostic ImagingMalePathologymedicine.medical_specialtyMultispectral imageBiomedical EngineeringSkin PigmentationOptical densityBiomaterialsLesionHemoglobinsImage Processing Computer-AssistedHumansMedicineMelanomaSkinMelaninsbusiness.industrySpectrum AnalysisMelanomamedicine.diseaseAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOxyhemoglobinsFemalesense organsmedicine.symptomSkin melanomabusinessSkin lesionSoftwareBiomedical engineeringJournal of Biomedical Optics
researchProduct

3D and multispectral imaging for subcutaneous veins detection.

2009

The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…

Diagnostic ImagingOptics and PhotonicsComputer sciencemedia_common.quotation_subjectMultispectral imageImage processingInfusions Subcutaneouslaw.inventionCatheterizationVeinsAutomationOpticsImaging Three-DimensionallawMedical imagingImage Processing Computer-AssistedContrast (vision)Humansmedia_commonModels StatisticalSpectroscopy Near-InfraredSpectrometerOrientation (computer vision)business.industryEquipment DesignMercuryLinear discriminant analysisImage EnhancementAtomic and Molecular Physics and OpticsSpectrophotometryArc lampbusinessOptics express
researchProduct

Multispectral integral imaging acquisition and processing using a monochrome camera and a liquid crystal tunable filter

2012

This paper presents an acquisition system and a procedure to capture 3D scenes in different spectral bands. The acquisition system is formed by a monochrome camera, and a Liquid Crystal Tunable Filter (LCTF) that allows to acquire images at different spectral bands in the [480, 680]nm wavelength interval. The Synthetic Aperture Integral Imaging acquisition technique is used to obtain the elemental images for each wavelength. These elemental images are used to computationally obtain the reconstruction planes of the 3D scene at different depth planes. The 3D profile of the acquired scene is also obtained using a minimization of the variance of the contribution of the elemental images at each …

Diagnostic ImagingPoint spread functionSynthetic aperture radarOptics and PhotonicsSkin NeoplasmsLightComputer scienceMultispectral imageImage processingPattern Recognition AutomatedMultispectral pattern recognitionImaging Three-DimensionalOpticsThree-dimensional image acquisitionImage Processing Computer-AssistedmedicineLiquid crystal tunable filterHumansMonochromeMelanomaThree-dimensional sensingIntegral imagingModels StatisticalPixelbusiness.industryLiquid Crystal Tunable FilterThree-dimensional image processingReproducibility of ResultsEquipment DesignSpectral bandsMultispectral and hyperspectral imagingmedicine.diseaseAtomic and Molecular Physics and OpticsLiquid CrystalsSkin cancerbusinessAlgorithms
researchProduct

Contact and contactless diffuse reflectance spectroscopy: potential for recovery monitoring of vascular lesions after intense pulsed light treatment.

2011

Optical fiber contact probe diffuse reflectance spectroscopy and remote multispectral imaging methods in the spectral range of 400 to 1100 nm were used for skin vascular malformation assessment and recovery tracing after treatment by intense pulsed light. The results confirmed that oxy-hemoglobin relative changes and the optical density difference between lesion and healthy skin in the spectral region 500 to 600 nm may be successfully used for objective appraisal of the therapy effect. Color redness parameter a* = 2 is suggested as a diagnostic border to distinguish healthy skin and vascular lesions, and as the indicator of phototreatment efficiency. Valuable diagnostic information on large…

Diagnostic informationOptical fiberMaterials scienceDiffuse reflectance infrared fourier transformmedicine.medical_treatmentMultispectral imagePort-Wine StainBiomedical EngineeringColorIntense pulsed lightlaw.inventionBiomaterialsLesionDiffusionOpticslawmedicineHumansTelangiectasisSkinbusiness.industrySpectrum AnalysisVascular malformationNear-infrared spectroscopyPhototherapymedicine.diseaseAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsTreatment Outcomemedicine.symptombusinessHemangiomaBiomedical engineeringJournal of biomedical optics
researchProduct

Real-space multiple scattering method for angle-resolved photoemission and valence-band photoelectron diffraction and its application to Cu(111)

2011

Abstract: A computational method is presented for angle-resolved photoemission spectra (ARPES) and photoelectron diffraction (PED) in the ultraviolet regime. The one-step model is employed and both initial valence and final continuum states are calculated using the finite-cluster, real-space multiple scattering method. Thereby the approach is versatile and provides a natural link to core-level PED. The method is applied to the Cu(111) valence band and good agreement with experiment is found for both ARPES spectra and PED patterns. When the PED patterns are integrated over a filled band of a single-orbital symmetry, such as Cu-3d, we show, both numerically and analytically, that the exact th…

Diffraction3104 Condensed Matter PhysicsMaterials scienceValence (chemistry)530 PhysicsScatteringPhysics2504 Electronic Optical and Magnetic MaterialsAngle-resolved photoemission spectroscopy10192 Physics InstituteCondensed Matter Physicsmedicine.disease_causeMolecular physicsSpectral lineElectronic Optical and Magnetic MaterialsDelocalized electronmedicineValence bandUltravioletPhysical Review B
researchProduct

Wavelength-compensated time-sequential multiplexed color joint transform correlator

2010

We report a wavelength-compensated three-channel (RGB) joint transform correlator (JTC) for color pattern recognition using a ferroelectric liquid-crystal spatial light modulator (SLM) operating in binary pure phase modulation. We apply a previously reported time-multiplexing technique useful in creating wavelength-compensated diffraction patterns, based on the synchronization of properly scaled diffraction masks with the input wavelength selection obtained by applying a rotating RGB color-filter wheel to an Ar-Kr laser. The application of this technique to a JTC architecture permits real-time color object detection. In order to achieve a high light efficiency for the correlation process, w…

DiffractionChannel (digital image)Computer scienceMaterials Science (miscellaneous)ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONColorPhysics::OpticsMultiplexingIndustrial and Manufacturing EngineeringSpectral linePattern Recognition Automatedlaw.inventionOpticslawImage Processing Computer-AssistedComputer SimulationBusiness and International ManagementComputingMethodologies_COMPUTERGRAPHICSSpatial light modulatorbusiness.industryLasersSpectrum AnalysisLaserObject detectionLiquid CrystalsLiquid crystal on siliconRGB color modelbusinessPhase modulationApplied Optics
researchProduct

Fast algorithms for free-space diffraction patterns calculation

1999

Here we present a fast algorithm for Fresnel integral calculation. Some fast algorithms using the fast Fourier transform are analysed and their performance has been checked. These methods are of easy implementation, but are only valid for a specific range of distances. Fast algorithms based on the Fractional Fourier transform allow accurate evaluation of the Fresnel integral from object to Fraunhofer domain in a single step.

DiffractionComputer sciencebusiness.industryFast Fourier transformPhysics::OpticsFresnel integralAtomic and Molecular Physics and OpticsDiscrete Fourier transformFractional Fourier transformElectronic Optical and Magnetic MaterialsDiscrete Fourier transform (general)symbols.namesakeCyclotomic fast Fourier transformOpticsFourier transformsymbolsPseudo-spectral methodElectrical and Electronic EngineeringPhysical and Theoretical ChemistryHarmonic wavelet transformbusinessAlgorithmFresnel diffractionOptics Communications
researchProduct

Photodiffraction in InGaAs/InGaAsP multiple quantum wells enclosed in a microcavity

1997

Abstract We report new results on the diffraction properties of photoinduced gratings in InGaAs/InGaAsP MQW structures. The original feature of this device is that the QWs are enclosed in an asymmetric Fabry–Perot microcavity in order to increase the diffraction efficiency. We observe oscillations in the diffraction efficiency due to resonant effects in the microcavity. The experimental spectra are compared with theory. Diffraction efficiency at 1.55 μm attains a maximum value of 2.7% at a write beam fluence of 260 μ J cm −2 , and then decreases at higher fluences. We explain this phenomenon by an absorption saturation at high excitation.

DiffractionMaterials scienceCondensed Matter::Otherbusiness.industryPhysics::OpticsCondensed Matter PhysicsDiffraction efficiencyFluenceSpectral lineOpticsOptoelectronicsGeneral Materials ScienceElectrical and Electronic EngineeringbusinessDiffraction gratingExcitationBeam (structure)Quantum wellSuperlattices and Microstructures
researchProduct