A Geant4 simulation package for the sage spectrometer
2012
International audience; A comprehensive Geant4 simulation was built for the SAGE spectrometer. The simulation package includes the silicon and germanium detectors, the mechanical structure and the electromagnetic fields present in SAGE. This simulation can be used for making predictions through simulating experiments and for comparing simulated and experimental data to better understand the underlying physics.
Calibration of the RPC charge readout in the ARGO-YBJ experiment
2012
""The charge readout of Resistive Plate Chambers (RPCs) is implemented in the ARGO-YBJ experiment to measure the charged particle density of the shower front up to 10^4\\\/m^2, enabling the study of the primary cosmic rays with energies in the ''knee'' region. As the first time for RPCs being used this way, a telescope with RPCs and scintillation detectors is setup to calibrate the number of charged particles hitting a RPC versus its charge readout. Air shower particles are taken as the calibration beam. The telescope was tested at sea level and then moved to the ARGO-YBJ site for coincident operation with the ARGO-YBJ experiment. The charge readout shows good linearity with the particle de…
Commissioning of the vacuum system of the KATRIN Main Spectrometer
2016
The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. An integral energy analysis will be performed by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m[superscript 3], and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips ha…
Deconvolution of Multiple Spectral Lines Shapes by Means of Tikhonov’s Regularization Method
2013
We present deconvolution of multiple narrow Zeeman split Hg lines, emitted from Hg/Xe micro-size capillary and measured by the Fourier Transform spectrometer. The ill-posed inverse problem was solved using the Tikhonov& rsquo;s regularization method.
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
Determination of β-decay ground state feeding of nuclei of importance for reactor applications
2020
In β-decay studies the determination of the decay probability to the ground state (g.s.) of the daughter nucleus often suffers from large systematic errors. The difficulty of the measurement is related to the absence of associated delayed γ-ray emission. In this work we revisit the 4πγ−β method proposed by Greenwood and collaborators in the 1990s, which has the potential to overcome some of the experimental difficulties. Our interest is driven by the need to determine accurately the β-intensity distributions of fission products that contribute significantly to the reactor decay heat and to the antineutrinos emitted by reactors. A number of such decays have large g.s. branches. The method is…
Line intensities of CH3D in the Triad region: 6–10μm
2004
Abstract Line intensities of the three lowest fundamentals of the 12CH3D Triad are modeled with an RMS of 3.2% using over 2100 observed values retrieved by multispectrum fitting of enriched sample spectra recorded with two Fourier transform spectrometers. The band strengths of the Triad in units of 10−18 cm−1/(molecule cm−2) at 296 K are, respectively, 2.33 for ν6 (E) at 1161 cm−1, 1.75 for ν3 (A1) at 1307 cm−1 and 0.571 for ν5 (E) at 1472 cm−1. The total calculated absorption arising from 12CH3D Triad fundamentals is 4.65×10−18 cm−1/(molecule cm−2) at 296 K. In addition, some 740 intensities of nine hotbands are fitted to 8.1%; most of the hotband measurements belong to 2ν6−ν6 and ν3+ν6−ν3…
Unveiling anion-induced folding in tripodal imidazolium receptors by ion-mobility mass spectrometry.
2021
The anion-induced folding of tripodal imidazolium receptors has been investigated by NMR spectroscopy, electrospray ionization ion mobility mass spectrometry and DFT calculations. Such folding can be switched by anion release upon collision induced dissociation.
COMMISSIONING OF THE SPEDE SPECTROMETER WITH STABLE BEAMS
2017
The SPectrometer for Electron DEtection (SPEDE) has been constructed for in-beam nuclear structure studies using radioactive ion beams. SPEDE employs a silicon detector for detecting conversion electrons. It is designed to be used in conjunction with the MINIBALL spectrometer at HIE-ISOLDE, CERN. Peer reviewed
The large-area micro-channel plate entrance detector of the heavy-ion magnetic spectrometer PRISMA
2005
This paper describes the entrance detector of the magnetic spectrometer PRISMA recently installed at Legnaro. The detector is based on rectangular (80 x 100 mm(2)) Micro-Channel Plates (MCP). It provides a fast time signal and its position-sensitive anode allows to extract the X and Y information. It exploits an electrostatic field for the acceleration of secondary electrons from a thin Carbon foil (similar or equal to 20 mu g/cm(2)) onto the MCP assembly. The electrons are guided by a parallel magnetic field. Good performances were obtained in the laboratory tests. The detector is presently installed at the entrance of PRISMA and gives resolutions <= 400 ps in time, and 1 mm in both X and …