Photobleaching effects onin vivoskin autofluorescence lifetime

2015

The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …

AdultTime FactorsMaterials scienceLightPhotochemistryBiomedical EngineeringHuman skinAbsorption (skin)LipofuscinBiomaterialsNuclear magnetic resonanceFlavinsIntradermal NevusmedicineHumansNevusskin and connective tissue diseasesPhospholipidsSkinInflammationPhotobleachingbusiness.industryEquipment DesignMiddle AgedHandmedicine.diseasePhotobleachingFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsAutofluorescenceSpectrometry FluorescenceOxyhemoglobinsPicosecondFlavin-Adenine DinucleotideNevus IntradermalOptoelectronicsbusinessJournal of Biomedical Optics
researchProduct

Presence of mycotoxins in sorghum and intake estimation in Tunisia

2014

Sorghum samples (n = 60) from Tunisian markets were analysed for the occurrence of 22 of both traditional and emerging mycotoxins. Samples were extracted with a QuEChERS-like method and mycotoxins were detected by LC-MS/MS. This method was validated and adequate analytical parameters were obtained. All samples had contamination with mycotoxins and several samples had higher contamination levels than European Union legislative limits (MLs). The most frequently found mycotoxins were ENB (100%), OTA (98%), ENA₁ (63%), ENB₁ (56%), BEA (48%), AFB1 (38%) and STG (33%). Mean contaminations were 30.7, 1.93, 33.2, 51.0, 15.4, 1.49 and 20.5 µg kg(-1), respectively. While two samples were contaminated…

AdultVeterinary medicineDaily intakeHealth Toxicology and MutagenesisPopulationFood ContaminationToxicologychemistry.chemical_compoundTandem Mass SpectrometryLc ms msHumansmedia_common.cataloged_instanceEuropean unionChildMycotoxineducationSorghummedia_commoneducation.field_of_studyMolecular Structurebiologybusiness.industryPublic Health Environmental and Occupational HealthGeneral ChemistryGeneral MedicineMycotoxinsContaminationSorghumbiology.organism_classificationDietBiotechnologychemistrybusinessChromatography LiquidFood ScienceFood Additives & Contaminants: Part A
researchProduct

Modulation of oestrogen excretion profiles by adjuvant chemotherapy in pre- and postmenopausal breast cancer.

1985

Modulation of steroid status by conventional chemotherapy was studied in 31 breast cancer patients receiving CMF and in 31 age-matched breast cancer patients without any therapy, taken as controls. This was achieved through the study of oestrogen excretion profiles using previously identified parameters and referring not only to classical but also to the “other”, namely catechol and unusual, oestrogen metabolites. After CMF treatment the premenopausal patients exhibit a modified excretion pattern, mainly concerning a marked and significant reduction of classical oestrogens, as shown by pattern indices. Because there is evidence that oestriol metabolism is not markedly affected by CMF treatm…

Adultmedicine.medical_specialtyTime FactorschlormethineAdjuvant chemotherapymedicine.medical_treatmentBreast NeoplasmsBiochemistryestriolGas Chromatography-Mass SpectrometrySteroidExcretionEndocrinologyBreast cancerInternal medicineestradiolAntineoplastic Combined Chemotherapy ProtocolsmedicineestrogenHumansStage (cooking)CyclophosphamideChromatography High Pressure LiquidAgedbusiness.industryEstrogensMetabolismMiddle Agedmedicine.diseaseestroneEstrogens CatecholEndocrinologyMethotrexateMetabolic rateAdrenal CortexFemaleFluorouracilMenopausebusinessAfter treatmentJournal of steroid biochemistry
researchProduct

Effective Henry's law partitioning and the salting constant of glyoxal in aerosols containing sulfate.

2013

The reversible partitioning of glyoxal was studied in simulation chamber experiments for the first time by time-resolved measurements of gas-phase and particle-phase concentrations in sulfate-containing aerosols. Two complementary methods for the measurement of glyoxal particle-phase concentrations are compared: (1) an offline method utilizing filter sampling of chamber aerosols followed by HPLC-MS/MS analysis and (2) positive matrix factorization (PMF) analysis of aerosol mass spectrometer (AMS) data. Ammonium sulfate (AS) and internally mixed ammonium sulfate/fulvic acid (AS/FA) seed aerosols both show an exponential increase of effective Henry's law coefficients (KH,eff) with AS concentr…

AerosolsAmmonium sulfateMolalityChromatography010504 meteorology & atmospheric sciencesSulfatesAnalytical chemistryGeneral ChemistryGlyoxal010501 environmental sciencesMass spectrometry01 natural sciencesHenry's lawAerosolchemistry.chemical_compoundchemistryIonic strengthTandem Mass SpectrometryEnvironmental ChemistryGlyoxalSaltsSulfateChromatography High Pressure Liquid0105 earth and related environmental sciencesEnvironmental sciencetechnology
researchProduct

Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid mic…

2012

One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads c…

AerosolsAtmospheric pressureChemistryDrop (liquid)Analytical chemistryAnalytic Sample Preparation MethodsAnalytic Sample Preparation MethodsReproducibility of ResultsMass spectrometryArticleAnalytical ChemistryAfterglowSpectrochemistryAtmospheric PressureLimit of DetectionCalibrationMass spectrumMicrotechnologySample preparationAnalytical chemistry
researchProduct

Towards comprehensive non-target screening using heart-cut two-dimensional liquid chromatography for the analysis of organic atmospheric tracers in i…

2021

Abstract Non-target screening of secondary organic aerosol compounds in ice cores is used to reconstruct atmospheric conditions and sources and is a valuable tool to elucidate the chemical profiles of samples with the aim to obtain as much information as possible from one mass spectrometric measurement. The coupling of mass spectrometry to chromatography limits the results of a non-target screening to signals of compounds within a certain polarity range based on the utilized stationary phases of the columns. Comprehensive two-dimensional liquid chromatography (LCxLC) introduces a second column of different functionality to enable the analysis of a broader range of analytes. Conventional LCx…

AerosolsDetection limitChromatography Reverse-PhaseAnalyteChromatographyChemistryHydrophilic interaction chromatographyOrganic ChemistryGeneral MedicineRepeatabilityMass spectrometrySnowBiochemistryMass SpectrometryAnalytical ChemistryAerosolVolume (thermodynamics)Hydrophobic and Hydrophilic InteractionsChromatography LiquidJournal of Chromatography A
researchProduct

Gel Electrophoresis Coupled to Inductively Coupled Plasma−Mass Spectrometry Using Species-Specific Isotope Dilution for Iodide and Iodate Determinati…

2007

In this paper, we present an online coupling of gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of iodine species (iodide and iodate) in liquid (seawater) and aerosol samples. For the first time, this approach is applied to the analysis of small molecules, and initial systematic investigations revealed that the migration behavior as well as the detection sensitivity strongly depends on the matrix (e.g., high concentrations of chloride). These effects could consequently affect the accuracy of analytical results, so that they need to be considered for the analysis of real samples. The technique used for quantification is species-specifi…

AerosolsElectrophoresis Agar Gelchemistry.chemical_classificationTime FactorsIodideIodatesAnalytical chemistrychemistry.chemical_elementIodidesIsotope dilutionIodineMass spectrometrySensitivity and SpecificityMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundIsotopesSpecies SpecificitychemistrySample preparationTriiodideInductively coupled plasma mass spectrometryIodateAnalytical Chemistry
researchProduct

Real-Time Analysis of Ambient Organic Aerosols Using Aerosol Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (AeroFAPA-MS).

2015

Organic compounds contribute to a major fraction of atmospheric aerosols and have significant impacts on climate and human health. However, because of their chemical complexity, their measurement remains a major challenge for analytical instrumentation. Here we present the development and characterization of a new soft ionization technique that allows mass spectrometric real-time detection of organic compounds in aerosols. The aerosol flowing atmospheric-pressure afterglow (AeroFAPA) ion source is based on a helium glow discharge plasma, which generates excited helium species and primary reagent ions. Ionization of the analytes occurs in the afterglow region after thermal desorption and pro…

AerosolsIonsAtmospheric pressureChemistryAnalytical chemistryGeneral Chemistryrespiratory systemMass spectrometryIon sourceMass SpectrometryAerosolAfterglowIonAtmospheric PressureComputer SystemsIonizationMass spectrumEnvironmental ChemistryHumansOrganic ChemicalsEnvironmental sciencetechnology
researchProduct

Identification of organic hydroperoxides and hydroperoxy acids in secondary organic aerosol formed during the ozonolysis of different monoterpenes an…

2009

On-line ion trap mass spectrometry (ITMS) enables the real-time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive-ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction-chamber experiments. APCI in the positive-ion mode usually enables the detection of [M+H](+) ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on-line APCI-ITMS is presented. Organic peroxides containing a hydroper…

AerosolsOrganic peroxideChemical ionizationAir PollutantsSpectrometry Mass Electrospray IonizationOzonolysisAtmospheric pressureOrganic ChemistryAnalytical chemistryCarboxylic AcidsAtmospheric-pressure chemical ionizationHydrogen PeroxideOnline SystemsIon sourceAnalytical ChemistryPeroxideschemistry.chemical_compoundchemistryFunctional groupMonoterpenesPressureVolatilizationHydrogen peroxideSesquiterpenesSpectroscopyRapid communications in mass spectrometry : RCM
researchProduct

Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…

2009

The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …

AerosolsSpectrometry Mass Electrospray IonizationChromatographyChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryExtractive electrospray ionizationMass spectrometryTandem mass spectrometryFourier transform ion cyclotron resonanceIon sourceAnalytical ChemistryTandem Mass SpectrometryCyclohexenesSpectroscopy Fourier Transform InfraredMonoterpenesDirect electron ionization liquid chromatography–mass spectrometry interfaceChromatography High Pressure LiquidSpectroscopyBicyclic MonoterpenesAmbient ionizationRapid Communications in Mass Spectrometry
researchProduct