Search results for "Spectrophotometry"
showing 10 items of 644 documents
GFAAS determination of selenium in infant formulas using a microwave digestion method.
1994
A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.
Automated determination of reboxetine by high-performance liquid chromatography with column-switching and ultraviolet detection.
2000
A fully automated method including column-switching and isocratic high-performance liquid chromatography (HPLC) was developed for quantitative analysis of the new antidepressant reboxetine, a noradrenaline reuptake inhibitor. After serum injection into the HPLC system and on-line sample clean-up on a silica C8 (10x4.0 mm I.D.) clean-up column with an eluent consisting of 2.5% acetonitrile in deionized water, the chromatographic separation was performed on an analytical column (Lichrospher CN; 250x4.6 mm I.D.) with an eluent of acetonitrile-aqueous potassium phosphate buffer (0.008 M, pH 6.4) (50:50). The UV detector was set at 273 or 226 nm. The limit of quantification was about 15 ng/ml at…
Quality control of pharmaceuticals containing clenbuterol by thermal lens spectrometry.
1996
An ultrasensitive absorptiometric procedure for the determination of clenbuterol in pharmaceutical preparations was developed. Clenbuterol was diazotized with nitrite and coupled with 1-(naphthyl)ethylenediamine, and the absorbance of the azo dye formed was measured by both spectrophotometry and ultrasensitive thermal lens spectrometry (TLS). The TLS limit of detection was 1.5 ppb, 14-fold lower than with a Hewlett-Packard diode array spectrophotometer. Thus, the TLS procedure can be advantageously applied to quality control of clenbuterol at the individual dose level and in small samples. Repeatability as relative standard deviation was 1.5% (50 ppb, n = 6).
Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide.
2013
Very low concentrations (pg mL(-1) or sub-pg mL(-1) level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL(-1). However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement wit…
Automated determination of amisulpride by liquid chromatography with column switching and spectrophotometric detection.
2003
A fully automated chromatographic method including on-line blood serum or plasma clean-up, isocratic high-performance liquid chromatography (HPLC) and spectrophotometric detection was developed for quantitative analysis of the new antipsychotic drug amisulpride. After injection of serum or plasma onto the HPLC system and clean-up on a pre-column (10x4.0 mm I.D.) filled with Silica CN 20 micrometer (pore size 10 nm) by an eluent consisting of 8% acetonitrile in deionized water, the chromatographic separation was performed on Lichrospher CN (5 micrometer; 250x4.6 mm I.D.) by an eluent consisting of 50% acetonitrile and 50% aqueous potassium phosphate buffer (0.008 M, pH 6.4). The UV detector …
Thermal Lens Spectrometric Detection of Catecholamines after Oxidation to Aminochromes
1992
Abstract Experimental conditions for the spectrophotometric and thermal lens spectrometry (TLS) detection of catecholamines after oxidation to aminochromes with hexacyanoferrate (III) are optimized. At the low concentrations used in TLS, and in a 0.07 M citrate buffer, catecholamine oxidation can be performed at pH 7 and is immediate, whereas a lower pH value is required in spectrophotometry to avoid aminochrome polymerisation, the oxidation reactions being much slower. Similar TLS sensitivities are obtained for all catecholamines which facilitates HPLC evaluation. Sensitivity can be enhanced using a 50% ethanol-water medium. The linear dynamic range extends over two orders of magnitude, th…
Indirect spectrophotometric determination of p-aminobenzoic acid in sunscreen formulations by sequential injection analysis
2003
Abstract A simple indirect sequential injection spectrophotometric method for the determination of the UV-filter p -aminobenzoic acid (PABA) in sunscreen formulations is proposed. The determination is based on the reaction of PABA with hypochlorite in acidic medium and the subsequent measurement of the residual chlorine by using the well-known reaction with o -tolidine. The experimental variables involved in the sequential injection analysis (SIA) system (sandwich arrangement, volumes of sample and reagents, propulsion flow rate, reaction coil length) and adequate concentrations of reagents were studied. The SIA method has a linear range up to 20 μg ml −1 (3 s y / x / b detection limit) of …
Selective solid-phase extraction of organophosphorus pesticides and their oxon-derivatives from water samples using molecularly imprinted polymer fol…
2020
Abstract A molecularly imprinted polymer was synthesized and characterized to be used as solid-phase extraction sorbent for simultaneous chlorpyrifos and diazinon and their oxon derivatives. Several imprinted polymers were prepared and evaluated in a retention study of these analytes compared with a non-printed polymer. Several parameters affecting the extraction of imprinted polymer such as washing solvent, composition and volume of the eluting solvent and sample volume, were also investigated. Under the optimum conditions, the developed method provided satisfactory limits of detection ranging between 0.07 µg L−1 to 0.12 µg L−1 and the material showed an excellent reusability (> 50 reuses)…
Determination of sulphonamides in human urine by azo dye precolumn derivatization and micellar liquid chromatography
1995
Abstract A high-performance liquid chromatographic method for the determination of sulphonamides in urine is reported. The drugs (sulphadiazine, sulphaguanidine, sulphamethizole, sulphamethoxazole, and sulphathiazole) were diazotized with nitrite and coupled with N-(1-naphthyl)ethylenediamine dihydrochloride in a sodium dodecyl sulphate (SDS) micellar medium. Separation of the sulphonamide azo dyes was performed on a C18 column with a 0.05 M SDS-2.4% pentanol mobile phase, which permitted the direct injection of the urine samples. The limits of detection were in the 0.1–0.3 μg/ml range.
Multicommutation as an environmentally friendly analytical tool in the hydride generation atomic fluorescence determination of tellurium in milk.
2003
The aim of this study is to show the advantages of the emerging multicommutation methodology based on the use of solenoid valves for Te determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS). The delivery of a series of alternating sequential insertions of small volumes of samples and reagents gives rise to new hydrodynamic processes and exciting analytical potentials by controlling the time of flow through the on/off-switched solenoid valves. This drastically reduces the reagent consumption by a factor of 4 and the generation of effluents (590 mL h(-1) instead of 750 mL h(-1) generated by the continuous-mode measurement) and also provides an improvement in th…