Evaluation of the use of wavefront encoding to reduce depth-induced aberration in structured-illumination microscopy

2018

Three-dimensional imaging is affected by depth-induced spherical aberration (SA) when imaging deep into an optically thick sample. In this work, we evaluate the impact of SA on the performance of incoherent grating-projection structured illumination microscopy (SIM). In particular, we analyze the reduction of the contrast in the structured pattern and compare the reconstructed SIM images for different amounts of SA. In order to mitigate the impact of SA, we implement and evaluate in SIM a wavefront encoded imaging system using a square cubic (SQUBIC) phase mask, an approach shown previously to be successful in conventional microscopy.

WavefrontMaterials sciencebusiness.industrymedia_common.quotation_subjectStructured illumination microscopySample (graphics)Òptica Aparells i instrumentsReduction (complexity)Spherical aberrationOpticsEncoding (memory)MicroscopyContrast (vision)businessmedia_common
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

Reducing effects of aberration in 3D fluorescence imaging using wavefront coding with a radially symmetric phase mask.

2016

In this work, a wavefront encoded (WFE) imaging system built using a squared cubic phase mask, designed to reduce the sensitivity of the imaging system to spherical aberration, is investigated. The proposed system allows the use of a space-invariant image restoration algorithm, which uses a single PSF, to restore intensity distribution in images suffering aberration, such as sample–induced aberration in thick tissue. This provides a computational advantage over depth-variant image restoration algorithms developed previously to address this aberration. Simulated PSFs of the proposed system are shown to change up to 25% compared to the 0 µm depth PSF (quantified by the structural similarity i…

WavefrontPhysicsSpatial filterbusiness.industryImage processing02 engineering and technologyIterative reconstruction021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and Optics010309 opticsSpherical aberrationOptics0103 physical sciencesSensitivity (control systems)0210 nano-technologybusinessImage restorationWavefront codingOptics express
researchProduct

Spatial light modulator phase mask implementation of wavefront encoded 3D computational-optical microscopy

2015

Spatial light modulator (SLM) implementation of wavefront encoding enables various types of engineered pointspread functions (PSFs), including the generalized-cubic and squared-cubic phase mask wavefront encoded (WFE) PSFs, shown to reduce the impact of sample-induced spherical aberration in fluorescence microscopy. This investigation validates dynamic experimental parameter variation of these WFE-PSFs. We find that particular design parameter bounds exist, within which the divergence of computed and experimental WFE-PSFs is of the same order of magnitude as that of computed and experimental conventional PSFs, such that model-based approaches for solving the inverse imaging problem can be a…

WavefrontPhysicsSpatial light modulatorbusiness.industryMaterials Science (miscellaneous)Phase (waves)Industrial and Manufacturing Engineeringlaw.inventionInterferometrySpherical aberrationOpticsOptical microscopelawMicroscopyBusiness and International ManagementDivergence (statistics)businessApplied Optics
researchProduct

Depth-of-Field of the Accommodating Eye

2014

Our eyes project information from a three-dimensional world to a basically two-dimensional surface, corresponding to the photoreceptor plane in the retina. In theory, only one plane or surface of world can be in focus at one time. However, the eye exhibits a certain tolerance to out-of-focus images, a feature that is known as depth-of-focus (DOF). The corresponding distance range in which the objects are seen “clearly” is known as depth-of-field (DOFi). Although DOF and DOFi refer to an interval of distances or a dioptric range in the image and object space, respectively, both parameters define a similar concept and are usually interchangeable. This article will mainly refer to DOFi because…

accommodationAdultMaleCorneal Wavefront Aberrationdepth-of-fieldComputer scienceaccommodative lagRefraction OcularLegibilityadaptive opticsYoung AdultPsychometric functionHumansComputer visionDepth of fieldaccommodation responseDioptreWavefrontDepth Perceptiondepth-of-focusbusiness.industryAccommodation OcularPupilOriginal ArticlesOphthalmologyFar pointaberrationsFemaleArtificial intelligencespherical aberrationDepth perceptionbusinessAccommodationOptometryOptometry and Vision Science
researchProduct

Changes of the eye optics after iris constriction☆

2010

Purpose: To evaluate the possible change in the optics of the human eye after iris constriction. Methods: Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results: Significant variation in some aberration coefficients were found …

genetic structuresComputer scienceIrisAberraciones ocularesOcular aberrationsConstrictionOpticslcsh:OphthalmologyAberración esféricamedicinelcsh:QC350-467Spherical aberrationÓptica del ojoIris (anatomy)skin and connective tissue diseasesurogenital systembusiness.industryeye diseasesSpherical aberrationmedicine.anatomical_structurelcsh:RE1-994Eye opticsHuman eyeOriginal Articlesense organsbusinesslcsh:Optics. LightOptometry
researchProduct

Opto-mechanical artificial eye with accommodative ability.

2015

The purpose of this study was to describe the design and characterization of a new opto-mechanical artificial eye (OMAE) with accommodative ability. The OMAE design is based on a second-pass configuration where a small source of light is used at the artificial retina plane. A lens whose focal length can be changed electronically was used to add the accommodation capability. The changes in the OMAE's aberrations with the lens focal length, which effectively changes the accommodative state of the OMAE, were measured with a commercial aberrometer. Changes in power and aberrations with room temperature were also measured. The OMAE's higher-order aberrations (HOAs) were similar to the ones of th…

genetic structuresbusiness.industryComputer scienceeye diseasesAtomic and Molecular Physics and Opticslaw.inventionLens (optics)Spherical aberrationOpticsmedicine.anatomical_structurelawVisual accommodationmedicineFocal lengthHuman eyesense organsbusinessAccommodationOptics express
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct