Search results for "Standard addition"
showing 10 items of 72 documents
Feasibility and application of solvent assisted flavour evaporation and standard addition method to quantify the aroma compounds in flavoured baked m…
2006
International audience; In order to determine the feasibility of the solvent assisted flavour evaporation extraction (SAFE) technique and the standard addition method to quantify the aroma compounds retained in baked matrices after processing, three doughs that mainly vary in one ingredient, M1 (with eggs and palm oil), M2 (without eggs but with palm oil) and M3 (without eggs and without palm oil) were flavoured with an aromatic formulation of 19 different aroma compounds in propylene glycol that is responsible for a viennoiserie aromatic note. From the 19 aroma compounds added, 12 of them were quantified, so was also the propylene glycol. After the application of standard addition method 3…
Standard addition method in FIA. Comparison between different assemblies
1999
A comparison between the different proposed methods to perform the standard addition in an on-line way (flow injection analysis) is made. The different assemblies (reverse and conventional FIA) and the employed standards in every method are compared. Three analyses were carried out, two of them were analyses of samples of pH indicators (methylorange and chlorophenol red) prepared at an acid pH, while the standards were prepared at a basic pH. The third analysis was the analysis of chloride in different synthetic waters with a perfectly known composition for all the ions present in the samples. Besides a new method to perform the on-line standard addition is proposed, trying to reduce the co…
Fourier transform infrared spectrometric determination of Malathion in pesticide formulations
2004
Abstract An environmentally friendly methodology has been developed for quality control analysis of emulsifiable concentrate pesticide formulations containing Malathion as active ingredient, using flow injection analysis (FIA)–Fourier transform infrared (FTIR) spectrometry. Five microlitres samples were directly injected into a 3 ml closed FIA manifold, in which 2 ml of CHCl 3 was re-circulated at 1.96 ml min −1 . After homogenisation and sample measurement, 2 μl volumes of a Malathion standard were injected, taking absorbance measurements after each injection. Peak height of the chemigrams, established from peak area values between 1027 and 1017 cm −1 , corrected with a baseline fixed from…
Evaluation of the interelemental effect in X-ray fluorescence analysis by the total addition method
1992
An algorithm for quantifying interelemental effects in X-ray fluorescence techniques is developed. By applying an addition process, the ratio between the mass absorption coefficients of the analyte and the unknown sample (μi*/μs*) is calculated to correct the fluorescence intensity of the element to be determined and linearize the I-c calibration plot. This coefficient can be calculated graphically and numerically. The method is applied to the determination of tin in lead alloys with good results over wide concentration ranges.
Expanding the application of stir bar sorptive-dispersive microextraction approach to solid matrices: Determination of ultraviolet filters in coastal…
2018
This work describes a new method for the determination of organic compounds in solid samples based on the equilibrium desorption of the analytes in an aqueous phase followed by stir bar sorptive-dispersive microextraction (SBSDME). Sand samples, contaminated with UV filters due to bathing and recreational activities, were dispersed in an aqueous medium by using a coated stir bar with CoFe2O4@oleic acid magnetic nanoparticles. The UV filters were physically desorbed from the surface of the sand particles and rapidly adsorbed on the hydrophobic coating of the nanoparticles, which were retrieved by means of their magnetism after stopping the stirring. In this manner, both preconcentration of t…
Platinum and rhodium in potato samples by using voltammetric techniques
2019
Potato is a starchy, tuberous crop from the perennial Solanum tuberosum having high nutritional values. This paper is the first analytical approach to quantify Pt and Rh in vegetal food. In this study a total of 38 different potato samples produced in Europe and one in Australia were investigated. Determinations of Pt and Rh in potato samples were carried out by Differential pulse voltammetry (DPV/a) for platinum and by Adsorptive stripping voltammetry (AdSV) for Rh using standard addition procedure. Because no certified reference potatoes containing platinum and rhodium are available, we used addition standard method. The quantification limits for Pt and Rh are 0.007 and 0.0008 &mu
H-Point standard additions method for resolution of binary mixtures with simultaneous addition of both analytes
1995
Abstract The basis of the H-point standard additions method, HPSAM, with simultaneous addition of both analytes is proposed for the resolution of binary mixtures. It is a modification of the previously described H-point standard additions method that permits the resolution of both species from a unique calibration set by making the simultaneous addition of the two analytes. The method uses as analytical signals the absorbances at pairs of wavelengths where each species shows the same absorbance. The required data to apply the method are the absorbance values at the previously selected wavelengths for the sample alone and spiked with both species at known concentrations. Linear relations bet…
Determination of globotriaosylceramide in plasma and urine by mass spectrometry
2009
Abstract Background: Fabry disease is an X-chromosomally inherited lysosomal storage disorder leading to accumulation of glycosphingolipids, mainly globotriaosylceramide (ceramide-trihexoside, Gb3). Concentrations of Gb3 in plasma and urine have been used to diagnose Fabry disease and to monitor enzyme replacement therapy with recombinant α-galactosidase. Methods: Gb3 was purified from plasma or urine by combined liquid extraction/protein precipitation and solid-phase extraction, and was detected by flow-injection analysis electrospray mass spectrometry (MS) using multi-reaction-monitoring. Calibration was performed via standard addition using C17-Gb3 as internal standard. The most abundant…
Targeting metabolomics analysis of the sunscreen agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate in human urine by automated on-line solid-phase ext…
2011
The in vivo metabolism of the xenobiotic agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate (EDP), a UV filter commonly used in sunscreen cosmetic products, was studied by targeting metabolomics analysis in human urine. The metabolomic study involved the use of urine from male and female volunteers before and after application of an EDP-containing sunscreen cosmetic. The metabolism of EDP in urine was studied by using the triple quadrupole detector in a combination of Precursor Ion Scanning and Neutral Loss Scanning modes, with and without enzymatic hydrolysis. Detected metabolites were subsequently confirmed as glucuronide conjugates of 4-(N,N-dimethylamino)benzoic acid and 4-(N-methylamino)…
Application of the slurry technique to biological materials: a survey of literature
1991
The literature on the application of the slurry technique to biological materials is reviewed. It is obvious from the various applications that the most frequently employed atomization method for slurry analysis in biological materials is electrothermal atomization using either graphite tube or platform atomizers. The slurry technique is particularly useful when certified reference materials are not available and when the standard addition method is to be avoided. The literature survey revealed that this technique compares favourably with other methods for the determination of trace metals in biological materials.