Modelling of a prosumer’s substation in a district heating network: validation and dynamic analysis
Thermal grids will play a key role in the development of local energy communities and the achievement of 100% renewable societies. However, challenges are related to the capability of dealing with the increasing number of producers which could supply heat to thermal grids. Indeed, as in the case of the electricity grid, heat could be available for some hours in a day from RES plants installed at user level and distributed in the network (also referred to as “prosumers”). To achieve more reliable results when performing energy analyses of these innovative applications, there is a need to rely on accurate models of each component. For instance, substations are of paramount importance in the i…
Simple Circuit Models for Studying Global Earthing Systems
2007
The paper proposes three simple circuit models for the simulation of the behaviour of a global earthing system during different fault events. The models allow one the evaluation of the maximum earth potential rise at every possible fault location and for every possible fault event. The three considered fault events are: single-line-to-earth fault inside a MV/LV substation, double-earth-fault in a MV line, single-line-to-earth fault inside a HV/MV station. After having illustrated the hypotheses at the basis of the study, the circuit models for the three fault events are presented and a numerical example shows how to use them in order to check the "global safety" of the interconnected earthi…
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
On the hazardous situations due to the presence of HV/MV substations in urban areas
2017
The paper focuses on the hazardous situations that can rise in urban areas in case of earth fault inside a High Voltage/Medium Voltage station. IEEE and IEC/EN Standards and technical documents are examined and discussed, in order to propose some practical guidelines for a safe integration of such installations in contexts characterized by the presence of low voltage systems and not trained persons.
The Quest for Global Safety
2007
The authors present a systematic study on the factors that have influence on the establishment of the safety conditions ensuring the rise of Global Earthing Systems. Starting from the definition of Global Earthing System given by CENELEC Document HD 637 SI and from the results of the studies done on the last years on the interconnected earthing systems inside MV networks, the paper proposes some directions of deepening on the topic of Global Safety. Some of the themes whom the paper deals with are: the correct definition of proximity, interconnection and quasi-equipotentiality of the earth electrodes belonging to a Global Earthing System; the influence of the presence of HV/MV stations on h…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…
Legal Liability of Professional Engineers: The Case of a Fire at a Shopping Center
2019
In this paper, the authors discuss the legal liabilities of the professional engineer as both the engineer of record of a project and the construction site manager. In particular, this paper analyzes the case of a fire at an end-user MV/LV substation of a shopping center in Italy, occurred a few years after maintenance works on the electrical installation. The professional engineer who had designed and overseen the construction of the substation was accused of criminal negligence. The authors through the examination of applicable technical standards, as well as of safety regulations, demonstrate that the professional engineer had acted diligently and that there was no ground for the neglige…
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
New solutions for prefabricated secondary substations in the view of sustainability
2016
The secondary substations will assume an important role as “smart nodes” of the smart grid. So in few years there will be a widespread dissemination on the territory of this apparatus. Consequently, great care have to be taken not only on safety issues, but also on the constructive methodology, in order to determine low environmental impact and decommissioning cost. This paper focuses on innovative solutions for the realization of prefabricated secondary substations, in the direction of sustainability. Innovative layout and enclosure topologies have been here taken into account. In particular, by considering that the substation concrete box is, at the same time, uneconomical and with strong…
A back to back method for the temperature rise test of prefabricated substations: A case study
2015
In this work a back to back method is presented which allows to develop heating tests of prefabricated secondary substations with a limited number of supplying equipment (an induction regulator and a capacitor bank). The proposed method makes use of the transformer tap changers to create a voltage difference on the medium voltage side. In this way, only an adjunctive low voltage supply is needed. With the proposed test system, the heating tests are developed on a 1000 kVA prefabricated substation. Thanks to the experimental tests, the class of enclosure of the substation and the operating temperature and resistance of the power transformers are determined, according to the recommendations o…