Search results for "Subtract"
showing 10 items of 134 documents
Delayed and incomplete treatment may result in dural fistula development in children with Vein of Galen malformation
2017
The association of dural arteriovenous fistulas (DAVF) in children with Vein of Galen malformation (VGM) has recently been reported for the first time. In a larger series of cases treated with transarterial NBCA embolization, 30% had DAVF. We wanted to analyze the development of DAVF in our cohort of children with VGM and to evaluate whether their occurrence depends on different treatment timing and embolic materials. We analyzed 43 VGM cases treated with a combined transarterial and transvenous approach between 2003 and 2016. In our early series until 2011, we used coils solely in 21 children. Since 2012, 22 children were treated with the combination of coils and Onyx. In the early series…
Three-Dimensional Contrast-Enhanced Magnetic Resonance Angiography in a Patient With Chronic Thromboembolic Pulmonary Hypertension Before and After T…
1999
The patient was a 69-year-old man with progressive dyspnea during the previous 5 years and no history of thromboembolic events. By means of spiral CT scanning and multiplanar digital subtraction angiography of the pulmonary arteries, chronic thromboembolic pulmonary hypertension was diagnosed. Mean pulmonary artery pressure and pulmonary vascular resistance were elevated to 46 mm Hg and 890 …
Digital Subtraction Angiography in Staging Renal Cell Carcinoma: Comparison with Computerized Tomography and Hlstopathology
1984
Digital subtraction angiography was compared to computerized tomography and histopathological findings for staging renal cell carcinoma in 24 patients. Injection of contrast material through a 16 gauge angiocatheter into the femoral vein provided digital subtraction cavography, digital subtraction arteriography and excretory urography during 1 investigation. Computerized tomography established the diagnosis in all patients, while digital subtraction angiography showed all angiographic signs of renal cell carcinoma in 14 (58 per cent). T staging was correct on computerized tomography in 18 patients and on digital subtraction angiography in 16. Absence or presence of venous involvement was in…
Subtractive imaging in confocal scanning microscopy using a CCD camera as a detector
2012
[EN] We report a scheme for the detector system of confocal microscopes in which the pinhole and a large-area detector are substituted by a CCD camera. The numerical integration of the intensities acquired by the active pixels emulates the signal passing through the pinhole. We demonstrate the imaging capability and the optical sectioning of the system. Subtractive-imaging confocal microscopy can be implemented in a simple manner, providing superresolution and improving optical sectioning. (C) 2012 Optical Society of America
Ergebnisse der kontrastverstärkten MR-Angiographie der aortoiliakalen Gefäße mit einem 1-molaren Kontrastmittel bei 1,0 T: Vergleich zur i. a. DSA
2004
PURPOSE To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) using a 1.0 molar contrast agent at 1.0 T for the diagnosis of abdominal aortic aneurysms and stenoses of renal or iliac arteries in comparison to intraarterial digital subtraction angiography (DSA). MATERIALS AND METHODS A total of 19 patients with the suspicion of abdominal aortic aneurysm or stenosis of renal or iliac arteries were examined with CE-MRA at 1.0 T. Intra-arterial DSA served as reference in all cases. After test bolus tracking, 10 or 8 ml of the 1.0 molar contrast agent Gadobutrol corresponding to a dose of 0.1 - 0.15 mmol/kg bw were injected and imaging performed using a FLASH-3D sequen…
Identification of DNA sequences specific for Vibrio vulnificus biotype 2 strains by suppression subtractive hybridization.
2005
ABSTRACT Vibrio vulnificus can be divided into three biotypes, and only biotype 2, which is further divided into serovars, contains eel-virulent strains. We compared the genomic DNA of a biotype 2 serovar E isolate (tester) with the genomic DNAs of three biotype 1 strains by suppression subtractive hybridization and then tested the distribution of the tester-specific DNA sequences in a wide collection of bacterial strains. In this way we identified three plasmid-borne DNA sequences that were specific for biotype 2 strains irrespective of the serovar and three chromosomal DNA sequences that were specific for serovar E biotype 2 strains. These sequences have potential for use in the diagnosis…
Effects of cadmium exposure on sea urchin development assessed by SSH and RT-qPCR: metallothionein genes and their differential induction
2012
In order to study the defense strategies activated by Paracentrotus lividus embryos in response to sub-lethal doses of CdCl2, we compared the induced transcripts to that of control embryos by suppression subtractive hybridization technique. We isolated five metallothionein (MT) cDNAs and other genes related to detoxification, to signaling pathway components, to oxidative, reductive and conjugative biotransformation, to RNA maturation and protein synthesis. RT-qPCR analysis revealed that two of the five P. lividus MT (PlMT7 and PlMT8) genes appeared to be constitutively expressed and upregulated following cadmium treatment, whereas the other three genes (PlMT4, PlMT5, PlMT6) are specifically…
Isolation of the left atrial surface from cardiac multi-detector CT images based on marker controlled watershed segmentation
2006
The delineation of left atrium (LA) and pulmonary veins (PVs) anatomy from high resolution images holds importance for atrial fibrillation (AF) investigation and treatment. In this study, a semiautomatic segmentation procedure for LA and PVs inner surface from contrast enhanced CT data was developed. The procedure consists of a three dimensional marker controlled watershed segmentation applied to the external morphological gradient, followed by variable threshold surface extraction from the original intensity image. A preliminary anisotropic non-linear filtering was implemented to improve the S/N ratio of CT images. The performance of segmentation was evaluated on cardiac CT scans of 12 AF …
Background Correction and Multivariate Curve Resolution of Online Liquid Chromatography with Infrared Spectrometric Detection
2011
J.K. acknowledges the “V Segles” grant provided by the University of Valencia to carry out this study. Authors acknowledge the financial support of Ministerio de Educación y Ciencia (Projects AGL2007-64567 and CTQ2008-05719/BQU) and Conselleria d'Educació de la Generalitat Valenciana (Project PROMETEO 2010-055).
Measurement of high energy resolution inelastic proton scattering at and close to zero degrees
2009
13 pages, 15 figures.-- Printed version published Jul 1, 2009.