Search results for "Switche"
showing 10 items of 77 documents
A fuel cell-battery hybrid power supply for portable applications
2010
Today, academic and industrial research is addressed to fuel cell based hybrid power supply in many fields of applications including stationary, automotive and portable electronics. Increasing source runtime, speeding up the transient response while minimizing weight, volume and cost of the power supply system are key requirements of all applications. According to the particular application, the power management system is optimized for a specific feature. In this paper, a fuel cell–battery hybrid power supply for a Digital Camera is proposed, although the control algorithm can be efficiently applied to any portable device. Thanks to an innovative control on the input power, any fuel cell pr…
Optimized Topology for High Efficiency Battery Discharge Regulator
2008
In the following years power levels of 20 kW to 50 kW will be demanded by the telecommunication satellites. It is not possible to keep 0.5 kW modules with up to 100 modules in parallel and, therefore, higher power modules must be used. A higher bus voltage seems also necessary and any voltage below 150 V and above 100 V could meet the needs. In addition, new optimized topologies that process only a part of the total power delivery can be employed to improve the efficiency. In this article, design guidelines and experimental results of a high efficiency battery discharge regulator (BDR) module based on parallel power processing are given.
A novel fuel cell-based power system modeling approach
2013
Nowadays, fuel cells are the most promising source of energy for stationary applications. Unfortunately, the power density of fuel cells is not adequate for modern applications. A fuel cell - based hybrid power supply is required. The fuel cell is coupled with a high-energy density power source to improve performances of the composite power source. A power management stage is introduced between the two basic sources to control the power flow path from the fuel cell to the auxiliary source and the load. In order to avoid effects of a limited power density of the fuel cell on the whole power supply, sophisticated power management algorithms are implemented. Accurate modeling is required to te…
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.
CVS: Using VLANs to Counteract the Effect of Topology Changes in Quasi-Static Mesh Access Networks
2006
Mesh networks are candidate to play the role of switched Ethernet LANs over extended areas and with a sensibly higher flexibility. Actually, mesh networks can exploit both Ethernet and wireless technologies, e.g. Wi-Fi and/or free-space optical links, to provide a high degree of redundancy in an access network, and to provide users with powerful means to connect with each other. By using such technologies, the mesh topology remains stable for hours, so that the mesh topology can be considered quasi-static. However, large meshes require a heavy overhead in the network control plane as for the management of end-to-end paths, which can change due to mobility of users and due to occasional fail…
Small-Signal Modeling of a Controlled Transformer Parallel Regulator as a Multiple Output Converter High Efficient Post-Regulator
2004
This paper presents a post-regulator based on the use of a controlled transformer, which adds or subtracts an additional voltage to the output filter of a converter in order to regulate its output voltage. So, their actuation is complementary to that of more known post-regulators, such as the magnetic amplifier (magamp) and synchronous switch post-regulator (SSPR), because the regulation is achieved by controlling the voltage across the filter inductor instead of its charge time. Besides, the post-regulator processes the power in parallel to the one flowing from input to output and only handles a percentage of it. The post-regulation by controlled transformer is suitable of being employed i…
Estimation of power supply harmonic impedance using a controlled voltage disturbance
2002
A novel method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the effectiveness of this measurement technique.
Off–on BODIPY-based chemosensors for selective detection of Al3+ and Cr3+versus Fe3+ in aqueous media
2014
[EN] Two new off-on BODIPY-based chemosensors that are highly sensitive for trivalent cations in aqueous solutions are described. Compound 2 exhibits selective sensing of Al3+ and Cr3+ versus Fe3+ through two different channels (UV-vis and fluorescence).
High-Frequency Experimental Characterization and Modeling of Six Pack IGBTs Power Modules
2016
In this paper, a method to characterize the high-frequency (HF) behavior of six pack insulated gate bipolar transistors (IGBTs) power module (PM) is presented. The method is based on experimental measurements at the external pins of the device and it allows one to extract internal inductive and capacitive parasitic coupling without the knowledge of structural and physical parameters of the PM. The HF model of a six pack IGBTs PM has been developed, in the frequency range of 150 kHz-30 MHz, and it has been implemented in MATLAB environment. The method has been experimentally validated by comparing the frequency behavior of the PM with the simulated response. Moreover, the HF conducted distur…
An AC-assisted single-nanowire electromechanical switch
2013
A unique two-source controlled nanoelectromechanical switch has been assembled from individual, single-clamped Ge nanowires. The switching behaviour was achieved by superimposing the control signals of specific frequencies to the electrostatic potential of the output terminals, eliminating the need for an additional gate electrode. Using an in situ manipulation technique inside a scanning electron microscope, we demonstrate that the pull-out force required to overcome adhesion at the contact can be significantly reduced by exciting mechanical resonant modes within the nanowire.