Search results for "TECNOLOGIA ELECTRONICA"
showing 10 items of 87 documents
Present Status and Future Perspectives of the NEXT Experiment
2014
Gómez Cadenas, Juan José et al.
NEXT-100 Technical Design Report (TDR). Executive summary
2012
[EN] In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ßß0v) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout pla…
Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment
2013
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100-150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it…
Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements
2013
[EN] The "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) is intended to investigate the neutrinoless double beta decay of Xe-136, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionucl…
Resultados de la estrategia farmacoinvasiva y de la angioplastia primaria en la reperfusión del infarto con elevación del segmento ST. Estudio con re…
2011
[EN] Introduction and objectives: Pharmacoinvasive strategy represents an attractive alternative to primary angioplasty. Using cardiovascular magnetic resonance imaging we compared the left ventricular outcome of the pharmacoinvasive strategy and primary angioplasty for the reperfusion of ST-segment elevation myocardial infarction. Methods: Cardiovascular magnetic resonance was performed 1 week and 6 months after infarction in two consecutive cohorts of patients included in a prospective university hospital ST-segment elevation myocardial infarction registry. During the period 2004-2006, 151 patients were treated with pharmacoinvasive strategy (thrombolysis followed by routine non-immediate…
Cardiovascular fitness in youth: association with obesity and metabolic abnormalities
2014
[ES] Las terapias que se implantan actualmente para la obesidad se centran en los aspectos nutricionales y sobre la actividad física. Con el fin de hacer que la actividad física sea una terapia positiva en vez de un desencadenador de discapacidades, es relevante evaluar de forma precisa el entrenamiento cardiovascular. Objetivo: evaluar el entrenamiento cardiovascular midiendo el consumo máximo de oxígeno y evaluar su relación con los parámetros cardiometabólicos clásicos. Métodos: se aplicó el protocolo modificado de Balke a 126 individuos caucásicos (60 % de varones), con edades entre 9 y 16 años, que se sometieron a una evaluación de obesidad. El grupo de no obesos consistía de individuo…
Texture analysis of cardiac cine magnetic resonance imaging to detect nonviable segments in patients with chronic myocardial infarction.
2017
[EN] Purpose: To investigate the ability of texture analysis to differentiate between infarcted nonviable, viable, and remote segments on cardiac cine magnetic resonance imaging (MRI). Methods: This retrospective study included 50 patients suffering chronic myocardial infarction. The data were randomly split into training (30 patients) and testing (20 patients) sets. The left ventricular myocardium was segmented according to the 17-segment model in both cine and late gadolinium enhancement (LGE) MRI. Infarcted myocardium regions were identified on LGE in short-axis views. Nonviable segments were identified as those showing LGE 50%, and viable segments those showing 0 < LGE < 50% transmural …
Ejection Fraction by Echocardiography for a Selective Use of Magnetic Resonance After Infarction
2020
[EN] Background Cardiac magnetic resonance (CMR) permits robust risk stratification of discharged ST-segment-elevation myocardial infarction patients, but its indiscriminate use in all cases is not feasible. We evaluated the utility of left ventricular ejection fraction (LVEF) by echocardiography for a selective use of CMR after ST-segment-elevation myocardial infarction. Methods Echocardiography and CMR were performed in 1119 patients discharged for ST-segment-elevation myocardial infarction included in a multicenter registry. The prognostic power of CMR beyond echocardiography-LVEF was assessed using adjusted C statistic, net reclassification improvement index, and integrated discriminati…
Prognostic implications of dipyridamole cardiac MR imaging: a prospective multicenter registry
2011
Purpose: To evaluate dipyridamole cardiac magnetic resonance (MR) imaging in the prediction of major events (MEs) in patients with ischemic chest pain in a large multicenter registry. Materials and Methods: Institutional ethics committee approval and written informed consent were obtained. A total of 1722 patients who were undergoing cardiac MR imaging for chest pain were included. Wall motion abnormalities (WMAs) at rest, hyperemia perfusion defect (PD), late gadolinium enhancement (LGE), and inducible WMA were analyzed (abnormal if more than one abnormal segment was seen) with the 17-segment model. A cardiac MR categorization was created: category 1, no PD, LGE, or inducible WMA; category…
Differentiation between acute and chronic myocardial infarction by means of texture analysis of late gadolinium enhancement and cine cardiac magnetic…
2017
[EN] The purpose of this study was to differentiate acute from chronic myocardial infarction using machine learning techniques and texture features extracted from cardiac magnetic resonance imaging (MRI). The study group comprised 22 cases with acute myocardial infarction (AMI) and 22 cases with chronic myocardial infarction (CMI). Cine and late gadolinium enhancement (LGE) MRI were analyzed independently to differentiate AMI from CMI. A total of 279 texture features were extracted from predefined regions of interest (ROIs): the infarcted area on LGE MRI, and the entire myocardium on cine MRI. Classification performance was evaluated by a nested cross-validation approach combining a feature…