Search results for "TRID"

showing 10 items of 753 documents

Post-Processing via Cation Exchange Cartridges: Versatile Options

2012

New 68Ge/68Ga radionuclide generators provide the positron emitter 68Ga (T½ = 67.7 min) as an easily available and relatively inexpensive source of a PET nuclide for labeling of interesting targeting vectors. However, currently available “ionic” 68Ge/68Ga radionuclide generators are not necessarily optimized for the routine synthesis of 68Ga-labeled radiopharmaceuticals in a clinical environment. Post-processing of 68Ge/68Ga generators using cation exchange resins provides chemically and radiochemically pure 68Ga with 97±2% within less than 4 min, with 68Ge almost completely removed, and ready for online labeling. This simple, fast, and efficient technology can be extended for new applicati…

chemistry.chemical_compoundCartridgechemistryRadiochemistrySynthonAcetonePositron emittersIonic bondingRadionuclide GeneratorIon-exchange resin
researchProduct

Impact of Gamma Radiation on Dynamic RDSON Characteristics in AlGaN/GaN Power HEMTs

2019

GaN high-electron-mobility transistors (HEMTs) are promising next-generation devices in the power electronics field which can coexist with silicon semiconductors, mainly in some radiation-intensive environments, such as power space converters, where high frequencies and voltages are also needed. Its wide band gap (WBG), large breakdown electric field, and thermal stability improve actual silicon performances. However, at the moment, GaN HEMT technology suffers from some reliability issues, one of the more relevant of which is the dynamic on-state resistance (R) regarding power switching converter applications. In this study, we focused on the drain-to-source on-resistance (R) characteristic…

Materials scienceassurance testingRadiation effects02 engineering and technologyHigh-electron-mobility transistorradiation hardness01 natural scienceslcsh:Technologylaw.inventiontotal ionizing dose (TID)lawPower electronics0103 physical sciencesGeneral Materials Sciencelcsh:MicroscopyHigh-electron-mobility transistor (HEMT)Radiation hardeningLeakage (electronics)lcsh:QC120-168.85010302 applied physicsRadiation hardnessAssurance testinghigh-electron-mobility transistor (HEMT)lcsh:QH201-278.5business.industrylcsh:TTransistorWide-bandgap semiconductor021001 nanoscience & nanotechnologyThreshold voltageSemiconductorlcsh:TA1-2040Gallium nitride (GaN)adiation effectsradiation effectsOptoelectronicslcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringTotal ionizing dosegallium nitride (GaN)0210 nano-technologybusinesslcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Materials
researchProduct

WORLD REVISION OF DYSCRITOBAEUS PERKINS (HYMENOPTERA SCELIONIDAE)

Dyscritobaeus Platygastridae Scelionidae Scelioninae
researchProduct

EPR study of polymeric carbon nitride photocatalysts

2018

EPR spectrometry servea as a unique tool by characterization of polymeric carbon nitride photocatalysts and evaluation of its photocatalytic performance in suspension.

EPR study carbon nitride photocatalysisSettore CHIM/07 - Fondamenti Chimici Delle Tecnologie
researchProduct

Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.

1986

The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…

AdultMaleSpecific forcePhysiologyElectromyographyPublic Health Environmental and Occupational HealthSTRIDEGeneral MedicineAnatomyConcentricElasticityBiomechanical PhenomenaRunningPhysiology (medical)EccentricHumansOrthopedics and Sports MedicineForce platformFemaleGround reaction forceBiomechanics of sprint runningLung ComplianceBiomedical engineeringResultant forceMathematicsEuropean journal of applied physiology and occupational physiology
researchProduct

Effect of overground vs treadmill running on plantar pressure: Influence of fatigue

2013

Abstract The differences produced when running on a treadmill vs overground may call into question the use and validity of the treadmill as a piece of equipment commonly used in research, training, and rehabilitation. The aim of the present study was to analyze under pre/post fatigue conditions the effect of treadmill vs overground on plantar pressures. Twenty-seven recreational runners (17 men and 10 women) ran on a treadmill and overground at two speeds: S 1  = 3.33 m/s and S 2  = 4.00 m/s, before and after a fatigue protocol consisting of a 30-min run at 85% of their individual maximal aerobic speed (MAS). Contact time (CT in seconds), peak pressure (PP in kPa), and relative load (RL in …

AdultMalemedicine.medical_specialtyHeelContact timeBiophysicsSTRIDEPhysical exerciseRunningTreadmill runningPressuremedicineHumansOrthopedics and Sports MedicineTreadmillFatigueFootbusiness.industryPlantar pressureRehabilitationRepeated measures designBiomechanical PhenomenaMetatarsusmedicine.anatomical_structurePhysical therapyFemaleHeelbusinessGait & Posture
researchProduct

Previously undiagnosed Reinke edema as a cause of immediate postextubation inspiratory stridor

2015

Reinke edema (RE) is an uncommon lesion of the vocal folds and a potential cause of complications during airway management. We report the case of a woman with previously unknown RE admitted to the intensive care unit who experienced postextubation inspiratory stridor immediately after separation from mechanical ventilation. RE should be considered among causes of postextubation stridor.

Reinke edemamedicine.medical_treatmentStridorIntensive Care UnitSettore MED/41 - Anestesiologialaw.inventionLesionlawRisk Factorsotorhinolaryngologic diseasesmedicineIntubation IntratrachealHumansRenike edema Postextubation stridor airway managementInspiratory stridorMED/41 - ANESTESIOLOGIARespiratory SoundsAgedMechanical ventilationbusiness.industryGeneral Medicinerespiratory systemLaryngeal EdemaIntensive care unitRespiration Artificialrespiratory tract diseasesIntensive Care Unitsmedicine.anatomical_structureAnesthesiaVocal foldsAirway managementFemalemedicine.symptomRespiratory SoundbusinessHuman
researchProduct

Cubic boron nitride: A new prospective material for ultracold neutron application

2009

Abstract At the ultracold neutron (UCN) source of the TRIGA research reactor in Mainz, we have measured for the first time the material optical wall-potential of cubic boron nitride. The measurements were performed with a time-of-flight (TOF) spectrometer. The samples investigated had a wall-potential of ( 305 ± 15 ) neV . This value is in good agreement with the result extracted from neutron reflectometry data and theoretical expectations. Because of its high critical velocity for UCN and its good dielectric characteristics, cubic boron nitride coatings (isotopically enriched) will be useful for a number of applications in UCN experiments.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsFOS: Physical sciencesDielectricCritical ionization velocityTRIGACondensed Matter::Materials Sciencechemistry.chemical_compoundNuclear magnetic resonancechemistryBoron nitrideNeutronResearch reactorNeutron reflectometryNuclear Experiment (nucl-ex)Atomic physicsNuclear ExperimentNuclear ExperimentInstrumentation
researchProduct

Sara Stridsberg: Rakkauden Antarktis

2019

Kirja-arvostelu teoksesta Sara Stridsberg: Rakkauden Antarktis (Kärlekens Antarktis). Suom. Outi Menna. Tammi 2019. 303 s. nonPeerReviewed

Rakkauden Antarktiskirja-arvostelutväkivaltaStridsberg Sarakuolema
researchProduct

Scale composition and oxidation mechanism of the Ti–46Al–8Nb alloy in air at 700 and 800 °C

2011

It is known that the oxide scale formed on TiAl alloys is generally composed of a mixture of alumina (Al2O3) and titania (TiO2). The presence of niobium changes the activities of Ti and Al and influences the kinetics of oxidation and oxide layer composition. In this work, the Tie46Ale8Nb alloy was subjected to cyclic oxidation in air at 700 � C (for 2 and 24 h) and 800 � C (for 300 h). Scale composition was analyzed by means of different techniques including X-ray photoelectron spectroscopy, X-ray diffraction and secondary ion mass spectroscopy. The scale consisted of several layers. The outer layer was built of alumina (amorphous or with very fine grains), whereas the inner layer e mainly …

Materials scienceMechanical EngineeringDiffusionMetallurgyAlloyMetals and AlloysNiobiumOxideAnalytical chemistrychemistry.chemical_elementGeneral Chemistryengineering.materialTitanium nitrideAmorphous solidchemistry.chemical_compoundchemistryX-ray photoelectron spectroscopyMechanics of MaterialsMaterials ChemistryengineeringLayer (electronics)Intermetallics
researchProduct