A smart and operator independent system to delineate tumours in Positron Emission Tomography scans
2018
Abstract Positron Emission Tomography (PET) imaging has an enormous potential to improve radiation therapy treatment planning offering complementary functional information with respect to other anatomical imaging approaches. The aim of this study is to develop an operator independent, reliable, and clinically feasible system for biological tumour volume delineation from PET images. Under this design hypothesis, we combine several known approaches in an original way to deploy a system with a high level of automation. The proposed system automatically identifies the optimal region of interest around the tumour and performs a slice-by-slice marching local active contour segmentation. It automa…
Model-Based Dose Calculation Algorithms for Brachytherapy Dosimetry
2019
The purpose of this study was to review the limitations of dose calculation formalisms for photon-emitting brachytherapy sources based on the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) report and to provide recommendations to transition to model-based dose calculation algorithms. Additionally, an overview of these algorithms and approaches is presented. The influence of tissue and seed/applicator heterogeneities on brachytherapy dose distributions for breast, gynecologic, head and neck, rectum, and prostate cancers as well as eye plaques and electronic brachytherapy treatments were investigated by comparing dose calculations based on the TG-43 formalism …
A simple analytical method for heterogeneity corrections in low dose rate prostate brachytherapy
2015
In low energy brachytherapy, the presence of tissue heterogeneities contributes significantly to the discrepancies observed between treatment plan and delivered dose. In this work, we present a simplified analytical dose calculation algorithm for heterogeneous tissue. We compare it with Monte Carlo computations and assess its suitability for integration in clinical treatment planning systems. The algorithm, named as RayStretch, is based on the classic equivalent path length method and TG-43 reference data. Analytical and Monte Carlo dose calculations using Penelope2008 are compared for a benchmark case: a prostate patient with calcifications. The results show a remarkable agreement between …
Surgical evaluation of panoramic radiography and cone beam computed tomography for therapy planning of bisphosphonate-related osteonecrosis of the ja…
2015
The purpose of this retrospective study was to compare the clinical significance of panoramic radiography (orthopantomography [OPTG]) and cone beam computed tomography (CBCT) for therapy planning of bisphosphonate-related osteonecrosis of the jaw (BRONJ) by surgeons.Using standardized questionnaire, eight maxillofacial surgeons evaluated intraoral photographs of the clinical situation of 14 patients with BRONJ as well as the corresponding radiographic images (OPTG, CBCT). The presence of five typical BRONJ signs (bone-remodeling, periosteal reaction, osteosclerosis, sequestra, and continuity of cortical bone) was evaluated with OPTG and CBCT. The influence of radiologic information on thera…
Impact of rectal distension on prostate CBCT-based positioning assessed with 6 degrees-of-freedom couch
2018
International audience; Introduction: Prostate requires a daily correction of its 3-dimensional position in relation with rectal distension. In this study, we sought to determine whether rectal distension with respect to the rectal behavior might have an impact on prostate translations and/or rotations during prostate image guided radiation therapy using a 6 degrees-of-freedom (DOF) couch.Methods and materials: We reviewed the data from 39 patients with localized prostate cancer treated with protracted external radiation therapy using a 6 DOF couch. Before each fraction, a kilovoltage cone beam computed tomography (kV-CBCT) scan was performed. The automatic fusion algorithm was set to fuse …
High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity
2017
PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…
Focal or whole-gland salvage prostate brachytherapy with iodine seeds with or without a rectal spacer for postradiotherapy local failure: How best to…
2016
International audience; PURPOSE: Salvage prostate permanent implant (sPPI) for postradiation local failure provides high rates of biochemical control. The cumulative dose delivered to the prostate and the rectum is still unknown. METHODS AND MATERIALS: We reviewed the postimplant CT-based dosimetry of 18 selected patients who underwent sPPI with I-125 seeds for isolated biopsy-proven local failure several years after external beam radiation therapy. Ten patients had whole-prostate sPPI, and 8 patients had multiparametric MRI-based focal sPPI. In 8 patients, hyaluronic acid (HA) gel was injected into the prostate rectum space. RESULTS: The median cumulative biological effective dose after EB…
Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis
2017
PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…
External photon radiation treatment for prostate cancer: Uncomplicated and cancer-free control probability assessment of 36 plans
2019
[Purpose] To perform a systematic and thorough assessment, using the Uncomplicated and Cancer-Free Control Probability (UCFCP) function, of a broad range of photon prostate cancer RT treatments, on the same scenario (a unique pelvic CT set). UCFCP considers, together with the probabilities of local tumour control (TCP) and deterministic (late) sequelae (NTCP), the second primary cancer risk (SPCR) due to photon and neutron peripheral doses.
PERIPHERAL SURFACE DOSE FROM A LINEAR ACCELERATOR: RADIOCHROMIC FILM EXPERIMENTAL MEASUREMENTS OF FLATTENING FILTER FREE VERSUS FLATTENED BEAMS
2020
Abstract There is a growing interest in the use of flattening filter free (FFF) beams due to the shorter treatment times. The reduction of head scatter suggests a better radiation protection to radiotherapy patients, considering the expected decrease in peripheral surface dose (PSD). In this work, PSD of flattened (FF) and FFF-photon beams was compared. A radiochromic film calibration method to reduce energy dependence was used. PSD was measured at distances from 2 to 50 cm to the field border for different square field sizes, modifying relevant clinical parameters. Also, clinical breast and prostate stereotactic body radiotherapy (SBRT) plans were studied. For square beams, FFF PSD is lowe…