Improving cytocompatibility of Co28Cr6Mo by TiO 2 coating: gene expression study in human endothelial cells

2013

Cobalt-based materials are widely used for coronary stents, as well as bone and joint implants. However, their use is associated with high corrosion incidence. Titanium alloys, by contrast, are more biocompatible owing to the formation of a relatively inactive titanium oxide (TiO 2 ) layer on their surface. This study was aimed at improving Co28Cr6Mo alloy cytocompatibility via sol–gel TiO 2 coating to reduce metal corrosion and metal ion release. Owing to their role in inflammation and tissue remodelling around an implant, endothelial cells present a suitable in vitro model for testing the biological response to metallic materials. Primary human endothelial cells seeded on Co28Cr6Mo showe…

MaleCell typeBiocompatibilityBiomedical EngineeringBiophysicsBioengineeringInflammationBiochemistryBiomaterialsCoated Materials BiocompatibleMaterials TestingGene expressionmedicineHumansResearch ArticlesCells CulturedOligonucleotide Array Sequence AnalysisTitaniumRegulation of gene expressionChemistryMicroarray analysis techniquesGene Expression ProfilingMetallurgytechnology industry and agricultureEndothelial CellsProstheses and ImplantsCell biologyEndothelial stem cellGene expression profilingGene Expression RegulationFemaleChromium Alloysmedicine.symptomBiotechnologyJournal of The Royal Society Interface
researchProduct

Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

2011

Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…

MaleCone beam computed tomographyDentistryStatistics NonparametricSurgical FlapsImaging Three-Dimensionalstomatognathic systemmedicineHumansArchDental ImplantsTitaniumEdentulismAnalysis of VarianceDentitionbusiness.industryJaw Edentulous PartiallyDental Implantation EndosseousMandibleCone-Beam Computed TomographyMiddle Agedmedicine.diseasestomatognathic diseasesDental archmedicine.anatomical_structureTreatment OutcomeSurgery Computer-AssistedMaxillaComputer-Aided DesignFemaleImplantOral SurgerybusinessSoftwareClinical oral implants research
researchProduct

Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial

2016

The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with …

MaleGenetics and Molecular Biology (all)Pathologymedicine.medical_specialtyPlasma GasesArticle SubjectCleaning methodsImmunology and Microbiology (all)Statistical differencelcsh:MedicineDental AbutmentsBiochemistryGeneral Biochemistry Genetics and Molecular BiologySoft Tissue Responselaw.inventionPlasma Gase03 medical and health sciences0302 clinical medicineRandomized controlled trialDental AbutmentslawCollagen; Female; Humans; Male; Middle Aged; Mouth; Plasma Gases; Titanium; Wound Healing; Dental AbutmentsHumansMedicineddc:610TitaniumMouthWound HealingDental AbutmentBiochemistry Genetics and Molecular Biology (all)General Immunology and Microbiologybusiness.industrySignificant differencelcsh:RSoft tissue030206 dentistryGeneral MedicineMiddle AgedClinical StudyFemaleCollagenWound healingbusinessHuman030215 immunologyBiochemistry; Genetics and Molecular Biology (all); Immunology and Microbiology (all)BioMed Research International
researchProduct

Gene toxicity studies on titanium dioxide and zinc oxide nanomaterials used for UV-protection in cosmetic formulations

2010

Titanium dioxide and zinc oxide nanomaterials, used as UV protecting agents in sunscreens, were investigated for their potential genotoxicity in in vitro and in vivo test systems. Since standard OECD test methods are designed for soluble materials and genotoxicity testing for nanomaterials is still under revision, a battery of standard tests was used, covering different endpoints. Additionally, a procedure to disperse the nanomaterials in the test media and careful characterization of the dispersed test item was added to the testing methods. No genotoxicity was observed in vitro (Ames' Salmonella gene mutation test and V79 micronucleus chromosome mutation test) or in vivo (mouse bone marrow…

MaleMaterials scienceBiomedical EngineeringBone Marrow CellsNanotechnologyCosmeticsGene mutationToxicologymedicine.disease_causeCell LineNanomaterialsMicechemistry.chemical_compoundSalmonellaIn vivoCricetinaeAdministration InhalationMacrophages AlveolarmedicineAnimalsRats WistarMicronuclei Chromosome-DefectiveTitaniumChromatographyMutagenicity TestsBody WeightIn vitroNanostructuresRatschemistryData Interpretation StatisticalMicronucleus testTitanium dioxideZinc OxideMicronucleusSunscreening AgentsGenotoxicityNanotoxicology
researchProduct

MMP-2, MMP-9, and iNOS Expression in Human Dental Pulp Subjected to Orthodontic Traction

2009

Abstract Objective: To test the hypothesis that some metalloproteinases (MMP-2, MMP-9) and inducible nitric oxide synthetase (iNOS) enzymes in dental pulp samples do not vary when subjected to orthodontic treatment. Materials and Methods: Human dental pulps were taken from male and female patients (N=10; age 10–14 years). A straight wire technique was used with nickel-titanium or steel archwires. The increase of pressure applied on teeth was gradual. Five patients were subjected to premolar extractions after 14 months of treatment and one after 24 months. Samples were Bouin-fixed, paraffin-embedded, and afterwards processed for immunohistochemistry using anti-MMP-2, anti-MMP-9, and anti-iNO…

MaleSettore BIO/17 - IstologiaTime FactorsNitric oxide synthetaseAdolescentTooth Movement TechniquesNitric Oxide Synthase Type IIDentistryOrthodonticsMalocclusion Angle Class IIMatrix metalloproteinaseNickelFemale patientOrthodontic WiresPressurePremolarHumansMedicineBicuspidChildTitaniumOdontoblastsMMP-2Orthodontic wirebusiness.industrymedicine.diseaseImmunohistochemistryBiomechanical PhenomenaDental pulpiNOSmedicine.anatomical_structureMatrix Metalloproteinase 9SteelMatrix Metalloproteinase 2ImmunohistochemistryFemaleStress MechanicalTreatment timeMalocclusionMMP-9businessImmunohistochemistry Dental pulp MMP-2 MMP-9 iNOS.Dental AlloysFollow-Up StudiesThe Angle Orthodontist
researchProduct

Effects of titanium dioxide pigments on mouse peritoneal macrophages in vivo.

1982

MaleTitaniumHealth Toxicology and MutagenesisMacrophagesAcid PhosphataseCell CountGeneral MedicinePigments BiologicalToxicologyPollutionPigmentchemistry.chemical_compoundMicechemistryPhagocytosisIn vivovisual_artEnvironmental chemistryTitanium dioxidevisual_art.visual_art_mediumEcotoxicologyAnimalsAscitic FluidGlucuronidaseBulletin of environmental contamination and toxicology
researchProduct

A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Ma…

2012

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Me…

MaleZIRCONIUM ALLOYSDentistrychemistry.chemical_elementMandiblelaw.inventionDouble-Blind MethodRandomized controlled triallawalloyDental Prosthesis DesignHumansJaw EdentulousMedicinebone level implantBone leveledentulous mandibleORAL-HEALTHAdverse effectGeneral DentistryAgedAged 80 and overTitaniumSUPPORTED OVERDENTURESbusiness.industrySPLIT-MOUTHDental Implantation EndosseousTitanium alloySoft tissueSUCCESSOSSEOINTEGRATED IMPLANTSMiddle Agedddc:617.6Treatment OutcomeDental Prosthesis Designchemistryddc:618.97DENTAL IMPLANTSFemaleImplantZirconiumOral Surgerydouble-blindLocatorbusinessFOLLOW-UPITI IMPLANTSRCTTitaniumClinical implant dentistry and related research
researchProduct

Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible

2013

Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…

Malemedicine.medical_specialtymedicine.medical_treatmentBone ScrewsBiocompatible MaterialsDehiscenceCumulative survivalCohort StudiesSex FactorsRisk FactorsSurgical Wound DehiscencemedicineHumansLongitudinal StudiesRisk factorDevice RemovalAgedRetrospective StudiesTitaniumbusiness.industrySmokingAge FactorsMandibleRadiotherapy DosageRetrospective cohort studyMiddle AgedSurvival AnalysisSurgeryRadiation therapyMandibular NeoplasmsTreatment OutcomeOtorhinolaryngologyCarcinoma Squamous CellEquipment FailureFemaleSurgeryMandibular ReconstructionOral SurgerySegmental resectionComplicationbusinessBone PlatesFollow-Up StudiesJournal of Cranio-Maxillofacial Surgery
researchProduct

The Boundless World of Cranioplasty: A Multicenter Retrospective Study and Therapeutic Flow-Chart Patient-Specific Based.

2021

Background Cranioplasty is both a functional and aesthetical therapeutic option. In the clinical scenario every cranioplasty's material is potentially qualified to achieve the goal of calvarian reconstruction but there is a lack of agreement about the optimum choice, especially between the heterologous ones. The choice of cranioplasty widely depends on surgeon's personal preferences. In this retrospective multicentric study a comparative analysis of hydroxyapatite or titanium cranioplasties was carried on analyzing the main factors considered by the surgeon to choose a material rather than another one. Our results and data were compared with those reported in the scientific literature and a…

Malemedicine.medical_specialtymedicine.medical_treatmentMEDLINECranioplastyTherapeutic approachSexual and Gender MinoritiesPostoperative Complicationssynthetic cranioplastymedicineHumansIn patientReconstructive Surgical ProceduresHomosexuality MaleRetrospective StudiesDental ImplantsTitaniumSettore MED/27 - Neurochirurgiabusiness.industrySkullosteointegrationRetrospective cohort studyGeneral MedicinePatient specificPlastic Surgery Proceduresmost suitable material scoremedicine.diseaseCranioplastyComorbiditySurgeryOtorhinolaryngologyFlow chartSurgerybusinessThe Journal of craniofacial surgery
researchProduct

Sunscreen Products as Emerging Pollutants to Coastal Waters

2013

A growing awareness of the risks associated with skin exposure to ultraviolet (UV) radiation over the past decades has led to increased use of sunscreen cosmetic products leading the introduction of new chemical compounds in the marine environment. Although coastal tourism and recreation are the largest and most rapidly growing activities in the world, the evaluation of sunscreen as source of chemicals to the coastal marine system has not been addressed. Concentrations of chemical UV filters included in the formulation of sunscreens, such as benzophehone 3 (BZ-3), 4-methylbenzylidene camphor (4-MBC), TiO2 and ZnO, are detected in nearshore waters with variable concentrations along the day a…

Marine ChemistryMarine and Aquatic Scienceslcsh:MedicineHeavy MetalsOceanographyWater ChemistryAnalytical Chemistryvisual_art.visual_artistWater AnalysisWater QualityMicroalgaeWater pollutionlcsh:ScienceTitaniumMultidisciplinarySunbathingEcologyChemistryEcologyChemical OceanographyMarine EcologyChemical oceanographyZincChemistryEnvironmental chemistryvisual_artCoastal EcologyResearch ArticlePollutantsAlgal bloomPhosphatesBenzophenonesInhibitory Concentration 50Chemical AnalysisSunbathingMediterranean SeaHumansEnvironmental ChemistrySeawaterMarine ecosystemBiological oceanographyBiologyDiatomsPollutantBiological Oceanographylcsh:RKineticsSpainEarth SciencesSeawaterlcsh:QSunscreening AgentsWater Pollutants ChemicalEnvironmental Protection
researchProduct