Search results for "Toe"

showing 10 items of 3824 documents

Analytical Dynamics of Optical Similaritons

2007

We analytically describe the attraction of parabolic pulses towards a self-similar state in weakly dispersive nonlinear fibers with linear gain.

PhysicsNonlinear systemOpticsOptical propagationbusiness.industryFiber nonlinear opticsChirpOptoelectronicsPulse amplifiersbusinessOptical fibre amplifiersAnalytical dynamics
researchProduct

Hard X-ray resonant electronic spectroscopy in transition metal oxides

2005

K-edge X-ray absorption and 2p-XPS spectra of 3d-element oxides present spectral features which cannot be explained within a simple one-electron model. These features reveal the fine electronic structure of transition metal (TM) oxides valence states resulting from hybridized TM-3d and O-2p states, and the correlations between these valence electrons. In this paper, we show how resonant electronic spectroscopy (resonant Auger or resonant photoelectron spectroscopy) around the TM K-edge can be used to interpret the structures of the threshold and, with the help of theoretical calculation, to determine the electronic configuration of the excited ion. Quadrupolar transitions towards localized …

PhysicsNuclear and High Energy PhysicsAuger electron spectroscopyX-ray absorption spectroscopyValence (chemistry)XASOxidesElectronic structureElectron spectroscopyAuger spectroscopyCondensed Matter::Materials ScienceX-ray photoelectron spectroscopy32.80.Hd; 61.10.Ht; 71.20.BeCondensed Matter::Strongly Correlated ElectronsElectron configurationAtomic physicsValence electronPhotoemissionInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Time response of avalanche photodiodes as a function of the internal gain

1998

Abstract Using a red LED and a blue laser as a light source, time response of avalanche photodiodes and Metal-Resistive Silicon (MRS) layer avalanche photodiodes [1] has been measured. A strong dependence of the time resolution on the internal gain has been observed. The obtained results show that the increase of the internal gain improves the time resolution. However, there exists a critical value for the internal gain. Beyond this value a deterioration of the time resolution is observed.

PhysicsNuclear and High Energy PhysicsBlue laserAvalanche diodeSiliconbusiness.industrychemistry.chemical_elementFunction (mathematics)Critical valueAvalanche photodiodeOpticsTime responsechemistrySingle-photon avalanche diodeOptoelectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Time-dependent electric field in Al/CdTe/Pt detectors

2015

Abstract Al/CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopy, even though they suffer from bias-induced time instability (polarization). Polarization phenomena cause a progressive time-degradation of the spectroscopic performance of the detectors, due to hole trapping and detrapping from deep acceptor levels that directly control the electric field distribution. In this work we present experimental investigations on the electric field profile of planar Al/CdTe/Pt detectors by means of Pockels effect measurements. The time/temperature dependence of the electric field was investigated in a long time window (up to 10 h) and the correlation with the reverse c…

PhysicsNuclear and High Energy PhysicsDeep acceptor levelbusiness.industryTrappingAcceptorPockels effectCadmium telluride photovoltaicsCdTe detectorX-ray and gamma ray spectroscopyPlanarPolarizationElectric fieldElectric fieldOptoelectronicsAtomic physicsPolarization (electrochemistry)businessSpectroscopyPockels effectInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Untersuchung verschiedener Elektronenemissionsprozesse auf Mehrfachemission

1965

A comparison of the pulse hight distribution of several electron emission processes is drawn. Thermionic electrons, photoelectrons, field electrons and exoelectrons are found to be emitted as single electrons.

PhysicsNuclear and High Energy PhysicsField (physics)Physics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaElectron multiplierSecondary emissionNuclear fusionThermionic emissionElectronAtomic physicsPhotoelectric effectSecondary electronsZeitschrift f�r Physik
researchProduct

Improving the Performance of Quasi-Hemispherical CdZnTe Detectors Using Infrared Stimulation

2012

The influence of monochromatic optical stimulation with wavelengths from 400 to 1100 nm on the characteristics of CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light with wavelengths of 870-900 nm close to the absorption edge of the CdZnTe significantly improves the performance of the detector at room temperature. Improvement can be achieved with low-intensity IR illumination at 1-300 μW depending on the chosen wavelength of illumination. Higher intensity illumination was observed to lead to the degradation of the detector's spectrometric characteristics. IR radiation was noted to influence the detector's sensitivity, changing the equili…

PhysicsNuclear and High Energy PhysicsInfraredbusiness.industryDetectorWide-bandgap semiconductorlaw.inventionWavelengthFull width at half maximumOpticsNuclear Energy and EngineeringAbsorption edgelawOptoelectronicsElectrical and Electronic EngineeringbusinessDiodeLight-emitting diodeIEEE Transactions on Nuclear Science
researchProduct

A comparison of the performance of irradiated p-in-n and n-in-n silicon microstrip detectors read out with fast binary electronics

2000

Abstract Both n-strip on n-bulk and p-strip on n-bulk silicon microstrip detectors have been irradiated at the CERN PS to a fluence of 3×10 14 p cm −2 and their post-irradiation performance compared using fast binary readout electronics. Results are presented for test beam measurements of the efficiency and resolution as a function of bias voltage made at the CERN SPS, and for noise measurements giving detector strip quality. The detectors come from four different manufacturers and were made as prototypes for the SemiConductor Tracker of the ATLAS experiment at the CERN LHC.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryATLAS experimentDetectorBiasingSemiconductor deviceParticle detectorMicrostripSemiconductor detectorOptoelectronicsHigh Energy Physics::ExperimentbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Beam test of the ATLAS silicon detector modules

1998

Abstract Results are reported from a beam test of prototype silicon microstrip detectors and front-end electronics developed for use in the LHC detector ATLAS. The detector assemblies (“modules”) were 12 cm long and were read out with binary electronics. Both irradiated and unirradiated modules were measured in a 1.56 T magnetic field for efficiency, noise occupancy, and position resolution as a function of bias voltage, binary hit threshold, and detector rotation angle with respect to the beam direction.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryDetectorBinary numberBiasingNoise (electronics)medicine.anatomical_structureAtlas (anatomy)medicineOptoelectronicsHigh Energy Physics::ExperimentElectronicsbusinessInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Recent results from the ATLAS SCT irradiation programme

2000

Abstract The irradiation facility at the CERN proton synchrotron, set up to irradiate full-size prototypes of silicon microstrip detectors for the ATLAS semiconductor tracker, is described and measurements of the detector currents during irradiation are reported. The detector dark currents can be described by bulk radiation damage models demonstrating the radiation hardness of the detector design and allowing the current damage factor α and the acceptor introduction term β to be determined. Results from testbeam studies of a module with an irradiated detector and binary readout in a magnetic field and with the beam incident over a range of angles are reported. The hit efficiency and spatial…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryDetectorProton Synchrotronmedicine.anatomical_structureSemiconductorAtlas (anatomy)medicineRadiation damageOptoelectronicsHigh Energy Physics::ExperimentIrradiationbusinessInstrumentationRadiation hardeningNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Performance Studies of Pixel Hybrid Photon Detectors for the LHCb RICH Counters

2006

The Pixel Hybrid Photon Detector is a vacuum tube with a multi-alkali photo cathode, high voltage cross-focused electron optics and an anode consisting of a silicon pixel detector bump-bonded to a readout CMOS electronic chip fully encapsulated in the device. The Pixel HPD fulfils the requirements of the Ring Imaging Cherenkov counters of the LHCb experiment at LHC. The performances of the Pixel HPD will be discussed with reference to laboratory measurements, Cherenkov light imaging in recent beam tests, image distortions due to a magnetic field.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPixelPhysics::Instrumentation and Detectorsbusiness.industryCherenkov detectorVacuum tubeHigh voltageAtomic and Molecular Physics and OpticsCathodelaw.inventionOpticslawComputer Science::Computer Vision and Pattern RecognitionElectron opticsOptoelectronicsbusinessCherenkov radiationNuclear Physics B - Proceedings Supplements
researchProduct