Search results for "Torque"
showing 10 items of 373 documents
Implant insertion torque value in immediate loading : a retrospective study
2019
Background The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. Material and Methods In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant difference…
Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency an…
2020
Background This study aimed to evaluate the effect of the implant design and the presence of cortical bone in the primary stability, as well as analyze the differences between the stability measurements obtained by two different resonance frequency analysis (RFA) devices. Material and methods A total of 80 Klockner implants of two different models [40 Essential Cone implants (group A) and 40 Vega implants (group B)] were used. The implants were placed in two polyurethane blocks that simulated the mechanical properties of the maxillary bone. One block featured a layer of cortical bone that was absent from the other block. The primary stability of all implants was measured by insertion torque…
Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Viv…
2011
Background: Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. Purposes: The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Materials and Methods: Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investig…
Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
2020
Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading …
Model and Control Strategy Simulation of a Racing Series Hybrid Car
2014
Action-reaction principle of Energetic Macroscopic Representation (EMR) and its Inversion Based Control (IBC) is used to organize subsystems interconnection of Noao, a plug-in series hybrid race car equipped with lithium-ion battery pack and an engine/generator set as its range extender, according to the physical causality. Results from drive test of the real car are used to validate the model. The objective of this paper is to provide a dynamic model of this car in order to improve its control scheme and analyse the impact of its optimisation.
Dynamic Analysis of a 7 DOF Robot Using Fuzzy Logic for Inverse Kinematics Problem
2019
Abstract In this paper, a dynamic analysis for a redundant, serial robot, with seven degrees of freedom is presented. The dynamic model of the robot is based on importing a tri-dimensional CAD model of the robot into MATLAB®, Simulink®-Simscape™-SimMechanics™. One can import complete CAD assemblies, including all masses, inertias, joints, constraints, and tri-dimensional geometries, into the model. The first step for executing a dynamic analysis is to resolve the Inverse Kinematics (IK) problem for the redundant robot. Because this type of robot has seven degrees of freedom the IK resolution implies an infinite number of solutions. So, to be able to resolve the IK for this kind of robot a F…
Spin torques and magnetic texture dynamics driven by the supercurrent in superconductor/ferromagnet structures
2018
We introduce the general formalism to describe spin torques induced by the supercurrents injected from the adjacent superconducting electrodes into the spin-textured ferromagnets. By considering the adiabatic limit for the equal-spin superconducting correlations in the ferromagnet we show that the supercurrent can generate both the field-like spin transfer torque and the spin-orbital torque. These dissipationless spin torques are expressed through the current-induced corrections to the effective field derived from the system energy. The general formalism is applied to show that the supercurrent can either shift or move the magnetic domain walls depending on their structure and the type of s…
Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque …
2017
International audience; Objective To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency.Design A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dyna…
Solid rotor induction machines for use in electrically-assisted turbochargers
2006
The stator leakage reactance has a major influence on the performance of a solid rotor induction machine. It is larger and it is more difficult to define and calculate than in a cage-rotor machine. When the higher leakage reactance is taken into account, the equivalent circuit model gives predictions of sufficient precision for design purposes. The airgap, normally chosen to be quite small, is preferably quite large by general standards. The torque varies as (V/f) 3 which makes it difficult to provide a wide range of constant power operation in a variable speed application. Slitting the rotor helps to improve the characteristic for variable-speed duties.
In vivo localized gastrocnemius subtendon representation within the healthy and ruptured human Achilles tendon
2022
The Achilles tendon (AT) is composed of three distinct in-series elastic subtendons, arising from different muscles in the triceps surae. Independent activation of any of these muscles is thought to induce sliding between the adjacent AT subtendons. We aimed to investigate displacement patterns during voluntary contraction (VOL) and selective transcutaneous stimulation of medial (MGstim) and lateral (LGstim) gastrocnemius between ruptured and healthy tendons, and to examine the representative areas of AT subtendons. Twenty-eight patients with unilateral AT rupture performed bilateral VOL at 30% of the maximal isometric un-injured plantarflexion torque. AT displacement was analysed from sagi…