Search results for "ULTRAVIOLET"
showing 10 items of 853 documents
High-performance liquid chromatographic determination of spironolactone and its major metabolite canrenone in urine using ultraviolet detection and c…
1994
A rapid and simple column liquid chromatographic method involving a column-switching system for the determination of spironolactone and its main metabolite canrenone in urine is described. Purification and concentration was performed using an Hypersil ODS-C18, 30 microns (20 x 2.1 mm I.D.) pre-column. The most polar urinary compounds were removed by washing the pre-column with water, and the analytes were subsequently switched to a LiChrospher RP C18, 5 microns (125 x 4 mm I.D.) analytical column and separated by means of an acetonitrile-water mobile-phase. Under the proposed conditions, the extraction efficiency was approximately 100% over the 0.5-10.0 micrograms/ml concentration range. Th…
Determination of hydroxytyrosol and tyrosol by liquid chromatography for the quality control of cosmetic products based on olive extracts
2014
An analytical method for the simultaneous determination of hydroxytyrosol and tyrosol in different types of olive extract raw materials and cosmetic cream samples has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different chromatographic parameters, such as mobile phase pH and composition, oven temperature and different sample preparation variables were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 35°C and isocratic elution of a mixture ethanol: 1% acetic acid solution at pH 5 (5:95, v/v) as mobile phase pumped at 1 mL min(-1). The detection wavelength was set at …
Determination of UV filters in both soluble and particulate fractions of seawaters by dispersive liquid–liquid microextraction followed by gas chroma…
2014
An analytical method to determine the total content (i.e., not only in the soluble fraction but also in the particulate one) of eight commonly used UV filters in seawater samples is presented for the first time. Dispersive liquid-liquid microextraction (DLLME) is used as microextraction technique to pre-concentrate the target analytes before their determination by gas chromatography-mass spectrometry (GC-MS). In order to release the UV filters from the suspended particles an ultrasound treatment is performed before DLLME. The ultrasound treatment time was studied in order to achieve a quantitative lixiviation of the target analytes. The type and volume of both disperser and extraction solve…
Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4…
2010
Abstract 2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by…
Determination of fungicide residues in fruits and vegetables by liquid chromatography–atmospheric pressure chemical ionization mass spectrometry
2002
Abstract A liquid chromatography (LC) method for the quantitative determination of five fungicide residues (dichloran, flutriafol, o -phenylphenol, prochloraz and tolclofos methyl) in oranges, lemons, bananas, peppers, chards and onions is described. The residues were extracted by matrix solid-phase dispersion (MSPD) using C 8 . Quantitative analysis was performed by isocratic LC coupled to quadrupole mass spectrometer using atmospheric pressure chemical ionization in the negative ionization mode. The limit of quantification was 0.01 mg kg −1 for flutriafol, o -phenylphenol and dichloran, and 0.1 mg kg −1 for prochloraz and tolclofos methyl. The MSPD method is also suitable for LC–UV analys…
Determination of water-soluble UV-filters in sunscreen sprays by liquid chromatography.
2002
Abstract Liquid chromatography was used for the determination of the three most used water-soluble UV filters, benzophenone-4 (BZ4), terephthalylidene dicamphor sulfonic acid (TDS), and phenylbenzimidazole sulphonic acid (PBS), in aqueous sunscreen sprays. A C 18 stationary phase and an isocratic mobile phase of EtOH–20 m M sodium acetate buffer of pH 4.6 (30:70, v/v) were used at a flow-rate of 0.5 ml min −1 . Mobile phase was also used as solvent for samples and standards. UV detection was at 313 nm. The analytical run took 5.5 min. The limits of detection were 0.5, 0.9 and 2 μg ml −1 for BZ4, TDS and PBS, respectively. The proposed method does not involve highly toxic solvents.
Spectrophotometric estimation of bicalutamide in tablets
2007
A simple, sensitive, rapid, accurate and precise spectrophotometric method has been developed for the estimation of bicalutamide in bulk and pharmaceutical dosage forms. Bicalutamide shows maximum absorbance at 272 nm with molar absorptivity of 2.3399×10(4) l/mol/cm. Beer's law was obeyed in the concentration range of 1.5-18 μg/ml. The limit of detection and limit of quantification were found to be 0.1 and 0.4 μg/ml, respectively. Results of analysis were validated statistically and by recovery studies.
Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…
2001
An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…
Solid-Phase Microextraction Liquid Chromatography/Tandem Mass Spectrometry To Determine Postharvest Fungicides in Fruits
2003
A method to determine five postharvest fungicides (dichloran, flutriafol, o-phenylphenol, prochloraz, tolclofos methyl) in fruits (cherries, lemons, oranges, peaches) has been developed using solid-phase microextraction (SPME) coupled to liquid chromatography (LC) with photodiode array (DAD), mass spectrometry (MS), or tandem mass spectrometry (MS/MS) with ion trap detection. Extraction involved sample homogenization with an acetone/water solution (5:1), filtration, and acetone evaporation prior to fiber extraction. The pesticides were isolated with a fused-silica fiber coated with 50-microm Carbowax/template resin. The effects of pH, ion strength, sample volume, and extraction time were in…
Use of micellar mobile phases for the chromatographic determination of clorazepate, diazepam, and diltiazem in pharmaceuticals
2001
An ODS-2 column, a micellar mobile phase of high elution strength containing 0.1M sodium dodecyl sulfate and 3% (v/v) butanol, and ultraviolet detection at 230 nm are used for the determination of either of two benzodiazepines (clorazepate and diazepam) and a benzothiazepine (diltiazem) in pharmaceuticals. The procedure is shown to be competitive against conventional chromatography with methanol-water mobile phases, especially for diltiazem. The composition of the micellar mobile phase is selected using a predictive strategy based on an accurate retention model and assisted by computer simulation. Calibration graphs are linear at least in the 2.5 to 20 microg/mL, 4 to 20 microg/mL, and 5 to…