Search results for "Ultrasonics"
showing 10 items of 326 documents
Magneto-optical characterization of single crystalline Co2FeAl0.4Si0.6thin films on MgO(1 0 0) substrates with Cr and MgO seed layers
2013
We report on the experimental investigation of the influence of a seed layer on the magnetic properties of the full-Heusler alloy Co2FeAl0.4Si0.6 (CFAS). The studied magnetic films are grown epitaxially on MgO (1 0 0) substrates with Cr and/or MgO seed layers. By employing magneto-optical Kerr effect magnetometry we show that magnetic anisotropy can be tuned by choosing the proper seed layer. The results on CFAS show an overall uniaxial anisotropy plus a biaxial contribution which depends on the seed layer. In addition, if grown on MgO, a sharp increase in the coercive field HC at a series of angles symmetric with respect to the easy axis is present. Scanning Kerr-microscope imaging is perf…
Laser ablation of a silicon target in chloroform: formation of multilayer graphite nanostructures
2013
With the use of high-resolution transmission electron microscopy, selected area electron diffraction and x-ray photoelectron spectroscopy methods of analysis we show that the laser ablation of a Si target in chloroform (CHCl3) by nanosecond UV pulses (40 ns, 355 nm) results in the formation of about 50–80 nm core–shell nanoparticles with a polycrystalline core composed of small (5–10 nm) Si and SiC mono-crystallites, the core being coated by several layers of carbon with the structure of graphite (the shell). In addition, free carbon multilayer nanostructures (carbon nano-onions) are also found in the suspension. On the basis of a comparison with similar laser ablation experiments implement…
Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes
2017
This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3mm wall thickn…
F-centre luminescence in nanocrystalline CeO2
2013
Nanocrystalline CeO2 powders were synthesized by two cost-effective methods: the self-propagating room temperature (SPRT) method and the precipitation method. Differently prepared samples exhibited different temperature-dependent photoluminescence (PL) in the ultraviolet and visible regions. The PL signals originated from different kinds of oxygen-deficient defect centres with or without trapped electrons (F0, F+ or F++ centres). The temperature-dependent PL spectra were measured using different excitation lines, below (457, 488 and 514?nm) or comparable (325?nm) to the ceria optical band gap energy, in order to investigate the positions of intragap localized defect states. Evidence for the…
New analytical approach to analyze the nonlinear regime of stochastic resonance
2015
We propose some approximate methods to explore the nonlinear regime of the stochastic resonance phenomenon. These approximations correspond to different truncation schemes of cumulants. We compare the theoretical results for the signal power amplification, obtained by using ordinary cumulant truncation schemes, that is Gaussian and excess approximations, the modified two-state approximation with those obtained by numerical simulations of the Langevin equation describing the dynamics of the system.
Histological and histomorphometric study using an ultrasonic crestal sinus grafting procedure: a multicenter case study
2016
Background: The aim of this study was to evaluate the efficacy of a hydrodynamic ultrasonic driven transcrestal sinus grafting procedure (Intralift ®, Acteon Company, Bordeaux, France) and the use of a bovine high temperature sintered grafting material in sinus sites with less than 5 mm remaining bone height with no additional autogenous bone in order to create a sufficient recipient site for implants. Material and Methods: 12 patients (16 sinus) in this multicenter case study were included. Using a crestal approach, bone under the sinus was prepared with ultrasonic tips until the Schneiderian membrane was reached. With a trumpet shaped instrument, the Schneiderian membrane was elevated. In…
Booton's problem re-examined
1998
The application of the stochastic linearization technique to the specific problem analyzed by Booton is reexamined. It is shown that Booton has made a subtle error in the procedure for minimization of the mean square force difference between the sharp limiter and its linear equivalent counterpart
Effects of acoustic stimulation on biochemical parameters in the digestive gland of Mediterranean mussel Mytilus galloprovincialis (Lamarck, 1819)
2020
Underwater sounds generated by anthropogenic activity can cause behavior changes, temporary loss of hearing, damage to parts of the body, or death in a number of marine organisms and can also affect healing and survival. In this study, the authors examined the effects of high-frequency acoustic stimulations on a number of biochemical parameters in the Mediterranean mussel, Mytilus galloprovincialis. During the experiment, animals were placed in a test tank and exposed to acoustic signals [a linear sweep ranging from 100 to 200 kHz and lasting 1 s, with a sound pressure level range of between 145 and 160 dBrms (re 1μParms)] for 3 h. Total haemocyte count was assessed and glucose levels, cyto…
Autocorrelation in meter induction: the role of accent structure.
2006
The performance of autocorrelation-based meter induction was tested with two large collections of folk melodies, consisting of approximately 13 000 melodies for which the correct meters were available. The performance was measured by the proportion of melodies whose meter was correctly classified by a discriminant function. Furthermore, it was examined whether including different melodic accent types would improve the classification performance. By determining the components of the autocorrelation functions that were significant in the classification it was found that periodicity in note onset locations was the most important cue for the determination of meter. Of the melodic accents includ…
Domain Wall Spin Structures in Mesoscopic Fe Rings probed by High Resolution SEMPA
2016
We present a combined theoretical and experimental study of the energetic stability and accessibility of different domain wall spin configurations in mesoscopic magnetic iron rings. The evolution is investigated as a function of the width and thickness in a regime of relevance to devices, while Fe is chosen as a material due to its simple growth in combination with attractive magnetic properties including high saturation magnetization and low intrinsic anisotropy. Micromagnetic simulations are performed to predict the lowest energy states of the domain walls, which can be either the transverse or vortex wall spin structure, in good agreement with analytical models, with further simulations …