Methane recovery efficiency in a submerged anaerobic membrane bioreactor (SAnMBR) treating sulphate-rich urban wastewater: Evaluation of methane loss…

2012

The present paper presents a submerged anaerobic membrane bioreactor (SAnMBR) as a sustainable approach for urban wastewater treatment at 33 and 20 C, since greenhouse gas emissions are reduced and energy recovery is enhanced. Compared to other anaerobic systems, such as UASB reactors, the membrane technology allows the use of biogas-assisted mixing which enhances the methane stripping from the liquid phase bulk. The methane saturation index obtained for the whole period (1.00 ± 0.04) evidenced that the equilibrium condition was reached and the methane loss with the effluent was reduced. The methane recovery efficiency obtained at 20 C (53.6%) was slightly lower than at 33 C (57.4%) due to …

Environmental EngineeringPilot ProjectsBioengineeringWaste Disposal FluidMethaneWater PurificationMembrane technologychemistry.chemical_compoundBioreactorsAnaerobiosisCitiesWaste Management and DisposalEffluentTECNOLOGIA DEL MEDIO AMBIENTEBiological Oxygen Demand AnalysisEnergy recoverySulfatesRenewable Energy Sustainability and the EnvironmentUrban wastewaterTemperatureEnvironmental engineeringMethane saturation indexMembranes ArtificialGeneral MedicineSubmerged anaerobic membrane bioreactor (SAnMBR)chemistryWastewaterBiofuelsGreenhouse gasDissolved methaneSewage treatmentSulphate-rich wastewaterMethaneAnaerobic exerciseBioresource Technology
researchProduct

Experimental study of the anaerobic urban wastewater treatment in a submerged hollow-fibre membrane bioreactor at pilot scale

2011

The aim of this study was to assess the effect of several operational variables on both biological and separation process performance in a submerged anaerobic membrane bioreactor pilot plant that treats urban wastewater. The pilot plant is equipped with two industrial hollow-fibre ultrafiltration membrane modules (PURON¿ Koch Membrane Systems, 30m 2 of filtration surface each). It was operated under mesophilic conditions (at 33°C), 70days of SRT, and variable HRT ranging from 20 to 6h. The effects of the influent COD/SO 4-S ratio (ranging from 2 to 12) and the MLTS concentration (ranging from 6 to 22gL -1) were also analysed. The main performance results were about 87% of COD removal, efflu…

Hollow-fibre membraneINGENIERIA HIDRAULICABiogasUltrafiltrationEffluentsPilot ProjectsWastewater treatmentWastewaterWaste Disposal FluidIndustrial effluentPerformance assessmentBioreactorsAnaerobiosisWaste Management and DisposalHollow fiber membranePriority journalPilot plantsVolatile fatty acidWaste water managementChemistryChemical oxygen demandUrban wastewaterMethanationMembraneGeneral MedicinePulp and paper industryWaste treatmentHollow fiber reactorWastewaterIndustrial membranesSeparation techniqueMethaneBioconversionEnvironmental EngineeringUltrafiltrationBioreactorBioengineeringArticleWater PurificationBiogasBioreactorMicrofiltrationCitiesEffluentBiological water treatmentTECNOLOGIA DEL MEDIO AMBIENTESubmerged anaerobic membrane bioreactorBiological Oxygen Demand AnalysisMembranesExperimental studyRenewable Energy Sustainability and the EnvironmentEnvironmental engineeringUrban areaMembranes ArtificialBiogas productionNonhumanAnaerobic digestionPilot plantChemical oxygen demandAnoxic conditions
researchProduct

The operating cost of an anaerobic membrane bioreactor (AnMBR) treating sulphate-rich urban wastewater

2014

The objective of this study was to evaluate the operating cost of an anaerobic membrane bioreactor (AnMBR) treating sulphate-rich urban wastewater (UWW) at ambient temperature (ranging from 17 to 33 degrees C). To this aim, energy consumption, methane production, and sludge handling and recycling to land were evaluated. The results revealed that optimising specific gas demand with respect to permeate volume (SGDp) and sludge retention time (for given ambient temperature conditions) is essential to maximise energy savings (minimum energy demand: 0.07 kW h m(-3)). Moreover, low/moderate sludge productions were obtained (minimum value: 0.16 kg TSS kg(-1) CODRemoved), which further enhanced the…

INGENIERIA HIDRAULICAEnergy demandIndustrial-scale hollow-fibre membranesOperating costTreated waterAnaerobic membrane bioreactor (AnMBR)Environmental engineeringFiltration and SeparationAnaerobic membrane bioreactorEnergy consumptionMethaneAnalytical ChemistryEnergy consumptionchemistry.chemical_compoundWastewaterVolume (thermodynamics)chemistryEnvironmental scienceSulphate-rich urban wastewaterOperating costTECNOLOGIA DEL MEDIO AMBIENTE
researchProduct

Economic and environmental sustainability of an AnMBR treating urban wastewater and organic fraction of municipal solid waste

2016

[EN] The objective of this study was to evaluate the economic and environmental sustainability of a sub- merged anaerobic membrane bioreactor (AnMBR) treating urban wastewater (UWW) and organic fraction of municipal solid waste (OFMSW) at ambient temperature in mild/hot climates. To this aim, power requirements, energy recovery from methane (biogas methane and methane dissolved in the effluent), consumption of reagents for membrane cleaning, and sludge handling (polyelectrolyte and energy consumption) and disposal (farmland, landfilling and incineration) were evaluated within different operating scenarios. Results showed that, for the operating conditions considered in this study, AnMBR tec…

INGENIERIA HIDRAULICAEnvironmental EngineeringMunicipal solid waste0208 environmental biotechnologySewageIncineration02 engineering and technologyWastewater010501 environmental sciencesManagement Monitoring Policy and LawSolid WasteOrganic fraction of municipal solid waste (OFMSW)Waste Disposal Fluid01 natural sciencesBioreactorsBiogasUrban wastewater (UWW)Ambient temperatureWaste Management and DisposalEffluentTECNOLOGIA DEL MEDIO AMBIENTE0105 earth and related environmental sciencesEnergy recoverySewageWaste managementSulfatesbusiness.industryAnaerobic membrane bioreactor (AnMBR)Life cycle analysis (LCA)TemperatureEnvironmental engineeringMembranes ArtificialGeneral MedicineRefuse Disposal020801 environmental engineeringIncinerationEnergy consumptionWaste Disposal FacilitiesWastewaterBiofuelBiofuelsCosts and Cost AnalysisEnvironmental sciencebusinessMethane
researchProduct

Filtration process cost in submerged anaerobic membrane bioreactors (AnMBRs) for urban wastewater treatment

2015

[EN] The objective of this study was to evaluate the effect of the main factors affecting the cost of the filtration process in submerged anaerobic membrane bioreactors (AnMBRs) for urban wastewater (UWW) treatment. Experimental data for CAPEX/OPEX calculations was obtained in an AnMBR system featuring industrial-scale hollow-fiber (HF) membranes. Results showed that operating at J(20) slightly higher than the critical flux results in minimum CAPEX/OPEX. The minimum filtration process cost ranged from Euro0.03 to Euro0.12 per m(3), mainly depending on SGD(m) (from 0.05 to 0.3 m(3)m(-2)h(-1)) and MLSS (from 5 to 25 gL-1). The optimal SGD(m) resulted in approx. 0.1 m(3)m(-2)h(-1).

Industrial-scale hollow-fiber membranesINGENIERIA HIDRAULICAGeneral Chemical EngineeringFiltration and Separation02 engineering and technology010501 environmental sciences01 natural scienceslaw.invention020401 chemical engineeringlawBioreactorUrban wastewater (UWW)0204 chemical engineeringFiltrationTECNOLOGIA DEL MEDIO AMBIENTE0105 earth and related environmental sciencesChemistryProcess Chemistry and TechnologySubmerged anaerobic MBR (AnMBR)General ChemistryPulp and paper industryMembraneWastewaterProcess costingSewage treatmentBiochemical engineeringAnaerobic exerciseCAPEXOPEX
researchProduct

PDMS membranes for feasible recovery of dissolved methane from AnMBR effluents

2020

[EN] This study aimed to evaluate the feasibility of degassing membrane (DM) technology for recovering dissolved methane from AnMBR effluents. For that purpose, a PDMS membrane module was operated for treating the effluent from an AnMBR prototype-plant, which treated urban wastewater (UWW) at ambient temperature. Different transmembrane pressures and liquid flow rates were applied for evaluating methane recovery efficiency. Maximum methane recoveries were achieved when increasing the vacuum pressure and reducing the liquid flow rate, reaching a maximum methane recovery efficiency of around 80% at a transmembrane pressure (TMP) of 0.8 bars and a treatment flow rate (Q(L)) of 50 L h(-1). The …

Payback periodFiltration and Separation02 engineering and technology010402 general chemistry01 natural sciencesBiochemistryMethanechemistry.chemical_compoundGeneral Materials SciencePhysical and Theoretical ChemistryEffluentTECNOLOGIA DEL MEDIO AMBIENTEPDMS degassing MembraneTreated waterAnaerobic membrane bioreactor (AnMBR)Urban wastewaterMethane recovery021001 nanoscience & nanotechnologyPulp and paper industry0104 chemical sciencesVolumetric flow rateGreenhouse gas (GHG)MembranechemistryWastewaterGreenhouse gasEnvironmental science0210 nano-technology
researchProduct

Identification of effective parameters for anti-inflammatory concentration in València City's wastewater using fuzzy-set qualitative comparative anal…

2019

The current literature about pharmaceutical and personal care compounds (PPCPs) focuses on identifying their concentration and toxicological risk both in surface water and in wastewater. However, the influence of urban areas (population ageing, income level, hospitals and others) has not yet been analysed. Knowing how a population (and its facilities) affects PPCPs' presence in wastewater is important to identify the conditions that are responsible for their presence. In this work, the influence of water consumption, population ageing, income level, hospitals and nursing homes on the anti-inflammatory concentration have been analysed. To fill the gap between the quantitative data on PPCPs' …

Population ageingEnvironmental Engineering010504 meteorology & atmospheric sciencesPopulationAnti-Inflammatory AgentsDrinkingPPCPsWastewater010501 environmental sciencesWaste Disposal Fluid01 natural sciencesWWTPsDistrictsFuzzy LogicEnvironmental healthHumansEnvironmental ChemistryfsQCACitieseducationWaste Management and Disposal0105 earth and related environmental sciencesConsumption (economics)education.field_of_studyQualitative comparative analysisUrban wastewaterAge FactorsPollutionHospitalsNursing HomesWaste treatmentWastewaterWork (electrical)SpainIncomeEnvironmental scienceSewage treatmentAnti-inflammatoryWater Pollutants ChemicalEnvironmental Monitoring
researchProduct

Eutrophication control by lime addition: A preliminary approach in Sicilian reservoirs

2003

Sicilian reservoirs, a vital resource for this densely populated island, are undergoing increased eutrophication processes, due to the lack of urban waste treatment plants and to intense agriculture. Massive blooms of toxic cyanobacteria represent one of the most obvious consequences, and can be dangerous for population health. The possibility of a fast, even if only short term, recovery of water quality through application of lime, was tested through analysis of ion dynamics in two reservoirs, to develop an `emergency plan', to counteract cyanobacterial blooms and to decrease the risk for human health. The results indicate that these water bodies are suitable for lime treatments, even thou…

Resource (biology)Ecologybusiness.industryAquatic Scienceengineering.materiallanguage.human_languageUrban wasteAgricultureEnvironmental protectionPhytoplanktonlanguageengineeringEnvironmental scienceWater qualitybusinessEutrophicationSicilianLimeHydrobiologia
researchProduct

Città, economia circolare e pianificazione urbanistica

2019

Il progressivo sviluppo delle interdipendenze economiche a scala globale ha influenzato anche la rapida crescita della produzione d’inquinanti e rifiuti di ogni sorta, richiamando l’attenzione della comunità europea e delle nazioni unite sulle politiche urbane, la loro efficacia e la loro integrazione. Le città e le regioni urbane costituiscono le maggiori aree di criticità dove si concentra la maggiore produzione di rifiuti urbani con impatti negativi sulla salute umana e sull’ambiente. Per lungo tempo l’aumento dei rifiuti urbani è stato considerato, come altri inquinanti, un problema alla coda di ogni processo produttivo e di consumo ed è stato affrontato con strumenti settoriali, come d…

Settore ICAR/20 - Tecnica E Pianificazione UrbanisticaUrban waste circular economy town planning ecological infrastructureRifiuti urbani economia circolare pianificazione urbanistica infrastrutture ecologiche
researchProduct

New Trends in Urban Drainage Modelling

2019

This book addresses the latest research advances, innovations, and applications in the field of urban drainage and water management as presented by leading researchers, scientists and practitioners from around the world at the 11th International Conference on Urban Drainage Modelling (UDM), held in Palermo, Italy from 23 to 26 September, 2018. The conference was promoted and organized by the University of Palermo, Italy and the International Working Group on Data and Models, with the support of four of the world’s leading organizations in the water sector: the International Water Association (IWA), International Association for Hydro-Environment Engineering and Research (IAHR), Environmenta…

Urban Stormwater Modelling TransportSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleUrban Wastewater Water Quality MonitoringWater Management Urban HydrologyUrban Hydraulic Processes Drainage Engineering
researchProduct