Industrial-scale hollow-fiber membranesINGENIERIA HIDRAULICAGeneral Chemical EngineeringFiltration and Separation02 engineering and technology010501 environmental sciences01 natural scienceslaw.invention020401 chemical engineeringlawBioreactorUrban wastewater (UWW)0204 chemical engineeringFiltrationTECNOLOGIA DEL MEDIO AMBIENTE0105 earth and related environmental sciencesChemistryProcess Chemistry and TechnologySubmerged anaerobic MBR (AnMBR)General ChemistryPulp and paper industryMembraneWastewaterProcess costingSewage treatmentBiochemical engineeringAnaerobic exerciseCAPEXOPEXdescription
[EN] The objective of this study was to evaluate the effect of the main factors affecting the cost of the filtration process in submerged anaerobic membrane bioreactors (AnMBRs) for urban wastewater (UWW) treatment. Experimental data for CAPEX/OPEX calculations was obtained in an AnMBR system featuring industrial-scale hollow-fiber (HF) membranes. Results showed that operating at J(20) slightly higher than the critical flux results in minimum CAPEX/OPEX. The minimum filtration process cost ranged from Euro0.03 to Euro0.12 per m(3), mainly depending on SGD(m) (from 0.05 to 0.3 m(3)m(-2)h(-1)) and MLSS (from 5 to 25 gL-1). The optimal SGD(m) resulted in approx. 0.1 m(3)m(-2)h(-1).
year | journal | country | edition | language |
---|---|---|---|---|
2015-10-22 |