Search results for "Visual Acuity"

showing 10 items of 456 documents

Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation

2011

PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…

AdultDepth of focusVisual acuityCorneal Wavefront AberrationPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityCorneaYoung AdultLens Implantation IntraocularCorneaRefractive surgerymedicineHumansDioptreLenses IntraocularDepth Perceptionbusiness.industryAblationRefractive Errorseye diseasesOphthalmologySpherical aberrationmedicine.anatomical_structureOptometryOftalmologíaSurgerysense organsmedicine.symptomDepth perceptionbusiness
researchProduct

Evolution of Corneal Graft Survival Over a 30-Year Period and Comparison of Surgical Techniques: A Cohort Study.

2015

Purpose To compare graft survival between 3 10-year periods and according to surgical techniques performed in the last years. Design Cohort study. Methods setting: Regional center (Besancon University Hospital, France). patients: All 1132 patients operated on between 1983 and 2014. Graft and patient baseline characteristics, risk factors for failure, surgical procedures, and postoperative corneal status were collected. main outcome measures: Five-year survival rate in the whole cohort; 1-year and 3-year survival rates, respectively, among 88 patients with endothelial dystrophy (ED) or postoperative bullous keratopathy (PBK) operated on using endothelial lamellar keratoplasty (ELK) or penetr…

AdultGraft RejectionMalemedicine.medical_specialtyKeratoconusTime FactorsCorneal graftVisual AcuityCorneal DiseasesCohort StudiesCorneal Transplantation03 medical and health sciences0302 clinical medicineRisk FactorsMedicineHumansProspective StudiesSurvival rateAgedbusiness.industryHazard ratioGraft SurvivalSurgical proceduresMiddle Agedmedicine.diseaseSurgeryOphthalmologyTreatment OutcomeCohort030221 ophthalmology & optometryBullous keratopathyFemaleFrancebusiness030217 neurology & neurosurgeryCohort studyFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Effects of Early Postfiltration Ocular Hypotony on Visual Acuity, Long-term Intraocular Pressure Control, and Posterior Segment Morphology

2001

Purpose To determine whether hypotony after filtration surgery has any influence on visual acuity and intraocular pressure (IOP) lowering. Patients and methods We prospectively investigated 43 eyes of 43 patients undergoing trabeculectomy without the use of antimetabolites for 12 months. Results The lowest postoperative IOP valued 4.9 +/- 3.6 mm Hg (range, 0-14 mm Hg). It correlated statistically significant with the IOP 6 weeks (P = 0.016), 6 months (P = 0.009), and 1 year after surgery (P = 0.027). Eyes with a deterioration of visual acuity 6 weeks after surgery had undergone a stronger postoperative hypotony (correlation with lowest postoperative IOP, P = 0.035). The mean period with an …

AdultIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresFundus Oculimedicine.medical_treatmentVisual AcuityGlaucomaOcular HypotensionTrabeculectomyOcular hypotonyRetinal DiseasesOphthalmologymedicineHumansTrabeculectomyProspective StudiesProspective cohort studyIntraocular Pressurebusiness.industryChoroid Diseasesmedicine.diseaseeye diseasesPosterior segment of eyeballOphthalmologyTreatment OutcomeFiltration surgerymedicine.symptombusinessGlaucoma Open-AnglePapilledemaJournal of Glaucoma
researchProduct

Changes in Accommodation and Ocular Aberration With Simultaneous Vision Multifocal Contact Lenses

2012

Objective: The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Methods: Eighteen young-adult subjects with a mean age of 29.8 +/- 2.11 years took part. Changes in accommodative response, spherical aberration (C-4(0)), horizontal coma (C-3(1)), vertical coma (C-3(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were…

AdultMaleAccommodative responseCross-Over StudiesOptical Phenomenagenetic structuresContact Lensesbusiness.industryVisual AcuityAccommodation OcularComa (optics)Mean ageRefraction Oculareye diseasesOphthalmologyOcular physiologySpherical aberrationCLs upper limitsHumansMedicineOptometryFemalebusinessAccommodationEye & Contact Lens: Science & Clinical Practice
researchProduct

Accommodative Functions with Multifocal Contact Lenses: A Pilot Study

2011

PURPOSE: To evaluate accommodative response and facility in presbyopic patients fitted with several types of simultaneous-image multifocal contact lenses (CLs). METHODS: Six presbyopic patients, unadapted wearers of simultaneous-image bifocals, were fitted with the Focus Progressives and the low- and high-addition Pure Vision simultaneous vision multifocal CLs. Each individual wore each of the three types of lenses in successive random order. Accommodative response, accommodative facility, visual acuity, and contrast sensitivity at distance and near were evaluated in all cases. A control group of eight non-presbyopic patients was also studied. RESULTS: The mean age was 28.6 +/- 2.72 and 51.…

AdultMaleAccommodative responseDistance visual acuityVisual acuityContact Lensesmedia_common.quotation_subjectVisual AcuityPilot ProjectsContrast SensitivityNear visionHumansMedicineContrast (vision)media_commonbusiness.industryAccommodation OcularEquipment DesignPresbyopiaPresbyopiaMiddle AgedPrognosismedicine.diseaseOphthalmologyOptometryFemalemedicine.symptombusinessAccommodationMaximum amplitudeFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Influence of contrast polarity on the accommodative response☆

2018

espanolObjetivo Evaluar los cambios de la respuesta acomodativa del ojo al leer un texto en diferentes condiciones de polaridad de contraste: letras negras sobre fondo blanco (condicion BoW) y letras blancas sobre fondo negro (condicion WoB). Metodos En este estudio experimental participaron dieciocho sujetos de edades comprendidas entre 21 y 41 anos. Se obtuvo objetivamente la respuesta acomodativa (AR) del ojo al leer un texto con polaridad de contraste BoW o WoB con un sistema de optica adaptativa que corregia todas las aberraciones salvo las propias del sujeto. Se estudiaron dos tamanos de letra diferentes (condiciones de agudeza visual), mostrados en una micropantalla. Se midio la AR d…

AdultMaleAccommodative responseOriginal articleBlack-on-white textgenetic structuresmedia_common.quotation_subjectPupil diameterVisual AcuityAgudeza visualContrast Sensitivity03 medical and health sciencesYoung Adult0302 clinical medicineAccommodative responseAyudas ópticas para baja visiónContrast polarityPolaridad de contrasteContrast (vision)Humansmedia_commonPhysicsAnalysis of VariancePupil sizeAccommodation OcularLow vision aidseye diseasesTexto blanco sobre negroWhite-on-black textReading030221 ophthalmology & optometryRespuesta acomodativaFemalesense organsHumanities030217 neurology & neurosurgeryTexto negro sobre blancoPhotic StimulationOptometryJournal of Optometry
researchProduct

Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"

2015

Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375

AdultMaleAdolescentLightmedicine.medical_treatmentVisual AcuityLentes de contactolcsh:MedicineBioinformaticsGeneral Biochemistry Genetics and Molecular BiologyContrast SensitivityCorneaYoung AdultDistortionMyopiamedicineHumansÓpticaScience & TechnologyGeneral Immunology and Microbiologybusiness.industrylcsh:ROrthokeratologyCorneal TopographyGeneral MedicineRefractive ErrorsTerm (time)OptometryFemaleCorrigendumbusinessOrthokeratologic Procedures
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Stereotactic fractionated radiotherapy in patients with optic nerve sheath meningioma.

2002

Abstract Purpose: To evaluate the effectiveness of stereotactic fractionated radiotherapy (SFRT) in the treatment of optic nerve sheath meningioma (ONSM). Methods and Materials: Between 1994 and 2000, a total of 39 patients with either primary ( n = 15) or secondary ( n = 24) ONSM were treated with SFRT and received a median total tumor dose of 54 Gy using 1.8 Gy/fraction. Results: The radiographic response to SFRT was documented in all patients as stable disease (no change) except for 1 patient with a partial response. After a median follow-up of 35.5 months, all patients with ONSM were alive without recurrence. The visual fields and visual acuity were improved in 6 of 15 and 1 of 16 exami…

AdultMaleCancer Researchmedicine.medical_specialtyVisual acuityTime FactorsFractionated radiotherapyErythemaAdolescentRadiographyRadiosurgerymedicineHumansRadiology Nuclear Medicine and imagingIn patientAge of OnsetAgedAged 80 and overRadiationbusiness.industryStandard treatmentOptic Nerve NeoplasmsDose fractionationMiddle Agedmedicine.diseaseSurgeryOptic nerve sheath meningiomaTreatment OutcomeOncologyDisease ProgressionFemaleRadiologyDose Fractionation Radiationmedicine.symptombusinessMeningiomaFollow-Up StudiesInternational journal of radiation oncology, biology, physics
researchProduct

The effect of aberrations on objectively assessed image quality and depth of focus

2017

The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…

AdultMaleDepth of focusCorneal Wavefront AberrationAdolescentImage qualityPopulationVisual AcuityComa (optics)Astigmatism050105 experimental psychologyYoung Adult03 medical and health sciences0302 clinical medicineOpticsOptical transfer functionAberrometrymedicineHumansComputer Simulation0501 psychology and cognitive scienceseducationVision OcularRetrospective StudiesMathematicsDepth Perceptioneducation.field_of_studybusiness.industryAberrometry05 social sciencesAstigmatismStrehl ratiomedicine.diseaseSensory SystemsOphthalmologyVisual Perception030221 ophthalmology & optometryFemalebusinessJournal of Vision
researchProduct