Search results for "Volt"
showing 10 items of 2187 documents
PD characteristics at Square Shaped Voltages Applying Two Different Detecting Techniques
2016
Nowadays power electronic converters are widely used and the fast switching voltage fronts results in an increased stress on the insulation material and may cause a reduction of the HV systems reliability. Nonsinusoidal voltage waveform have influence on the partial discharges (PD) characteristics in insulating systems due to the increased harmonic content which causes problems mainly in electrical PD measurement setups. In fact, impulse voltages cause strong switching disturbances, which make it much more difficult to distinguish PD signals from noise. This work investigates the influence of repetitive steep pulses on different types of test objects exposed to square wave voltages applying…
Partial discharges at different voltage waveshapes: Comparison between two different acquisition systems
2018
In modern HV apparatuses the wide use of electronic converters, increase the stress on the involved insulation systems and thus affect the reliability of the whole power grid. Additionally, such non-sinusoidal voltage shapes contain high gradient flanks that create problems in the detection of partial discharge (PD) activity. The aim of this paper is to discuss the methodology on how to suitably approach PD detection in insulation systems exposed to various voltage waveshapes in general by comparing two different measuring systems. The first one, equipped with a resonant PD decoupler, designed specifically for detection at typical power electronic waveshapes and the other one, based on an a…
Space charge behavior of different insulating materials employed in AC and DC cable systems
2017
In this work, the space charge accumulation in three different XLPE based material has been carried out by using the PEA (Pulsed Electro-Acoustic) method. The specimens provided by a cables industry have been subjected to the same DC stress during polarization time at environment temperature. Afterwards, the high voltage generator has been turned off and the amount residual charge has been evaluated. The space charge profiles during polarization and depolarization have been carried out and compared. Finally, the distribution of electric field within the samples has been reported. In particular, the maximum distortion of electric field has been calculated by taking into account the distribut…
Determination of Contact Potential Difference by the Kelvin Probe (Part II) 2. Measurement System by Involving the Composite Bucking Voltage
2016
Abstract The present research is devoted to creation of a new low-cost miniaturised measurement system for determination of potential difference in real time and with high measurement resolution. Furthermore, using the electrode of the reference probe, Kelvin method leads to both an indirect measurement of electronic work function or contact potential of the sample and measurement of a surface potential for insulator type samples. The bucking voltage in this system is composite and comprises a periodically variable component. The necessary steps for development of signal processing and tracking are described in detail.
Object size effect on the contact potential difference measured by scanning Kelvin probe method
2010
International audience; Contact potential difference (CPD) was measured by macroscopic Kelvin probe instrument and scanning Kelvin probe microscope on Al, Ni and Pt on ITO substrates at ambient conditions. CPD values measured by scanning Kelvin probe microscope and macroscopic Kelvin probe are close within the error of about 10-30% for large studied objects, whereas scanning Kelvin probe microscope signal decreases, when the object size becomes smaller than 1.4 m. CPD and electric field signals measured using many-pass technique allowed us to estimate the influence of electrostatic field disturbance, especially, in the case of small objects.
Determination of Contact Potential Difference by the Kelvin Probe (Part I) I. Basic Principles of Measurements
2016
Abstract Determination of electric potential difference using the Kelvin probe, i.e. vibrating capacitor technique, is one of the most sensitive measuring procedures in surface physics. Periodic modulation of distance between electrodes leads to changes in capacitance, thereby causing current to flow through the external circuit. The procedure of contactless, non-destructive determination of contact potential difference between an electrically conductive vibrating reference electrode and an electrically conductive sample is based on precise control measurement of Kelvin current flowing through a capacitor. The present research is devoted to creation of a new low-cost miniaturised measuremen…
SIC based solid state protections switches for space applications
2017
Development and technology maturation of Silicon Carbide (SiC) power transistors over the last 15 years has motivated its study in aerospace systems. When compared with Si devices, superior voltage blocking capacity and the capability of operation at higher temperatures, give important advantages in space power electronics applications, similar to what happens in terrestrial electronics. This paper discusses the use of SiC power transistors for Solid State Power Switches especially addressed to the space segment. Two applications will be covered, the first is the Solid State Shunt Switch, widely used in high power Direct Energy Transfer (DET) photovoltaic power regulators and the second is …
Contributed Review: Review of thermal methods for space charge measurement.
2016
The space charge accumulation phenomenon has garnered great interest over the last two decades because of the increased use of direct current in high voltage electrical systems. In this context, a significant relevance has been achieved by the thermal methods, used for solid dielectrics. This paper presents a review of this non-destructive measurement system used for the measurement of space charge. The thermal pulse method, the thermal step method, and the laser intensity modulation method are described. For each configuration, the principle of operation, the thicknesses analyzed, and the spatial resolution are described, reporting also the main related applications
ABSOLUTE THERMOELECTRIC POWER OF Pb–Sn ALLOYS
2011
International audience; In this work, absolute thermoelectric power (ATP) of Pb, Sn, Pb-20 wt.% Sn, Pb-40 wt.% Sn, Pb-60 wt.% Sn, Pb-80 wt.% Sn are measured. Measurements are performed in a temperature gradient furnace from 20 degrees C to 500 degrees C, for both solid and liquid states. Temperatures are measured with T-type copper-constantan thermocouples, while voltage signal between copper electrodes of those thermocouples is recorded in order to calculate ATP of the sample metal.
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…