Search results for "WASTE"
showing 10 items of 2580 documents
Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
2016
Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The fir…
Liquid chromatography–mass spectrometry as a tool for wastewater-based epidemiology: Assessing new psychoactive substances and other human biomarkers
2017
Wastewater-based epidemiology (WBE) started to develop significantly in the last 8 years due, in part, to the advance of liquid chromatography–mass spectrometry (LC–MS). Its initial objective ― to estimate the consumption of illicit drugs ― has been expanded to new psychoactive substances (NPS) and other human biomarkers of health, lifestyle and disease. The purpose of this review is to introduce recent methods and outstanding challenges in the application of LC–MS to these new targets, including target, suspect and non-target screening and, outline the workflows developed for discovering metabolites of NPS and biomarkers. Further, we discuss a number of specific methodological challenges t…
Determination of Phenols from Automobile Exhaust by Means of High-Performance Liquid Chromatography (HPLC)
1981
Abstract The paper describes a procedure to determine ten representative phenols (phenol, m-, p-, o-cresol, 2,4-, 2,6-, 3,4-, 3,5-xylenol, 2,3,6-, 2,4,6-trimethylphenol) in engine exhaust. Sampling was performed by a conventional Grimmer device. A sample of the water condensate collected was extracted with ether. After concentration of the ether extract phenols were isolated from other interfering compounds by stepwise elution on a Lobar column packed with LiChroprep Si 60 under controlled conditions. Relative recovery of the majority of reference phenols ranged from 90-100%. Separation of phenols into individual components was performed on polar packings as well as on Reverse Phase packing…
Solid-Phase Extraction of Organochlorine Pesticides from Water Samples
1990
Abstract A procedure for the accumulation of organochiorine pesticides by reversed-phase adsorption on octadecylsilica glass microcolumns was used for the isolation and concentration from spiked distilled and natural waters. The pesticides were eluted from the octadecylsilica with light petroleum, and analyzed by gas chromatography using an electron capture detector. The average recovery was over 90% in spiked water samples at 0.1 ng/ml. The performance of the octadecylsilica when applied to the analysis of water samples were compared with the Rodier and the APHA solvent extraction methods.
Cultivation of granular sludge with hypersaline oily wastewater
2015
The time required to stabilise mature aerobic granules is rather variable. In addition, cultivation time and the structural characteristics of granules seem to be related to the nature of wastewater influent. Granular sludge has been used for the treatment of several industrial wastewaters, but nothing has been reported about wastewater characterized by the simultaneous presence of hydrocarbons and high chloride concentration. In this work, the authors analysed the granulation process and performance as well as the physical characteristics of aerobic granules in two Granular Sequencing Batch Airlift Reactors (GSBARs), fed with acetate-based synthetic wastewater in reactor 1 (R1) and with a …
EDTA excess Zn(II) back-titration in the presence of 4-(2-pyridylazo)-resorcinol indicator and naphthol green beta as inert dye for determining Cr(II…
2006
The colour changes of 4-(2-pyridylazo)-resorcinol and naphthol green beta as new screening metallochromic indicator in back-titration of EDTA excess with Zn(II) to determine Cr(III)/EDTA complex was investigated with the help of tristimulus colorimetry. Specific colour discrimination (SCD) and L*, a*, b* 1976 parameters were successfully applied to evaluate the quality of colour transition at the end-point in non-alkaline media and in the presence of Zn(II) and Ca(II) which resulted in non-interfering species at 1x10(-3) M and 2x10(-3) M, respectively. The above concentrations are comparable with those used for Cr(III). Validation of the fast and accurate reported method was performed by at…
Chromium liquid waste inertization in an inorganic alkali activated matrix: Leaching and NMR multinuclear approach
2015
A class of inorganic binders, also known as geopolymers, can be obtained by alkali activation of aluminosilicate powders at room temperature. The process is affected by many parameters (curing time, curing temperature, relative humidity etc.) and leads to a resistant matrix usable for inertization of hazardous waste. In this study an industrial liquid waste containing a high amount of chromium (≈ 2.3 wt%) in the form of metalorganic salts is inertized into a metakaolin based geopolymer matrix. One of the innovative aspects is the exploitation of the water contained in the waste for the geopolymerization process. This avoided any drying treatment, a common step in the management of liquid ha…
Removal of trivalent chromium from tannery waste waters using bone charcoal
2002
International audience; The ability of bone charcoal to remove Cr(III) from aqueous solutions by adsorption has been investigated. The adsorbent used was first characterised and then the adsorption was studied as a function of time and amount of charcoal. Tests were carried out with synthetic solutions whose Cr concentrations (500 mg L-1) were similar to those found in some effluents of Moroccan tannery industries. Cr removal efficiencies higher than 90% were obtained at pH 3.5 using 3 g of bone charcoal and a stirring time of about 30 min. Results of Cr removal by all sieved fractions of bone charcoal had shown the same interesting capabilities for Cr(III) retention. The cross interference…
Cadmium and lead in infant cereals — electrothermal-atomic absorption spectroscopic determination
1999
Because infant cereals are an important component of the infant diet from the fourth month of life onwards and therefore contribute to the dietetic intake of metals by infants, cadmium and lead were measured in samples of cereals commercially available in Spain. For this purpose an electrothermal atomic absorption (ET-AAS) method for determining cadmium and lead in these products was studied. The ET-AAS instrumental conditions and temperature/time furnace program were selected. The analytical parameters of the method (linearity, detection and quantification limits and precision) show its usefulness in measuring cadmium and lead in infant cereal products. The method was applied to eight diff…
Ischemic cardiovascular disease in workers occupationally exposed to urban air pollution – A systematic review
2018
Introduction Cardiovascular disease is the first cause of morbidity and mortality worldwide. Among several known risk factors, researchers also focus their attention on the chronic exposure to air pollution. There is much evidence that exposure to air pollution, especially to ultrafine particles, can damage the endothelium and can favour cardiovascular diseases in the general population. Occupational exposition could be an additive risk factor for the cardiovascular system. This article presents a scientific review of the linkage between occupational exposure to air pollution and ischemic heart disease. Material and methods A scientific review was undertaken, followed by PRISMA Statements. …