Search results for "WAVELENGTH"
showing 10 items of 741 documents
Analysis of multi-spectral photoplethysmograph biosensors
2013
Multi-spectral photoplethysmograph biosensor intended for analysis of peripheral blood volume pulsations at different vascular depths has been experimentally tested. Light emitting diodes with four different wavelengths were used as the light emitters. A single photodiode with multi-channel signal output processing was used as the light detector. This study analyzed rising time difference between wavelengths at systole maximum, wavelengths relations between systole and diastole peak difference. The proposed methodology is discussed.
A magnetostrictive sensor interrogated by fiber gratings for DC-current and temperature discrimination
2000
A magnetostrictive sensor head with temperature compensation has been developed for measurement of static magnetic fields. The device consists on two different alloys with similar thermal expansion coefficient one of which has a giant magnetostriction, the expansion of both materials produced by heat and magnetism is detected by two fiber gratings. One of the gratings measures the temperature of the sensor and the difference between the wavelengths reflected by the gratings is a measurement of the magnetically induced strain.
Scanning electron microscopy study of twins in ZnSe single crystals grown by solid-phase recrystallization
2001
ZnSe single crystals were grown from n-type microcrystalline boules by a solid phase recrystallization (SPR) method. During SPR, twinned regions appear with different electronic recombination properties. The recrystallizations were performed under different atmospheres, Ar or Se, and pressures to investigate the influence of growth conditions on these structural features. Recombination properties were studied by means of cathodoluminescence (CL) and remote-electron beam induced current (REBIC). Wavelength dispersive X-ray (WDX) mappings were also performed to analyze possible differences in stoichiometry related to the presence of extended defects.
Two-Color Single Hybrid Plasmonic Nanoemitters with Real Time Switchable Dominant Emission Wavelength
2015
International audience; We demonstrate two-color nanoemitters that enable the selection of the dominant emitting wavelength by varying the polarization of excitation light. The nanoemitters were fabricated via surface plasmon-triggered two-photon polymerization. By using two polymerizable solutions with different quantum dots, emitters of different colors can be positioned selectively in different orientations in the close vicinity of the metal nanoparticles. The dominant emission wavelength of the metal/polymer anisotropic hybrid nanoemitter thus can be selected by altering the incident polarization.
Clinical measurements analysis of multi-spectral photoplethysmograph biosensors
2014
The developed portable multi-spectral photoplethysmograph (MS-PPG) optical biosensor device, intended for analysis of peripheral blood volume pulsations at different vascular depths, has been clinically verified. Multi-spectral monitoring was performed by means of a four – wavelengths (454 nm, 519 nm, 632 nm and 888 nm) light emitted diodes and photodiode with multi-channel signal output processing. Two such sensors can be operated in parallel and imposed on the patient’s skin. The clinical measurements confirmed ability to detect PPG signals at four wavelengths simultaneously and to record temporal differences in the signal shapes (corresponding to different penetration depths) in normal a…
Clinical measurements with multi-spectral photoplethysmography sensors
2012
A portable multi-spectral photoplethysmography device has been used for studies of 40 subjects. Multi-spectral monitoring was performed by means of a four - wavelengths (465 nm, 530 nm, 630 nm and 870 nm) light emitted diodes (LED) and a single photodiode with multi-channel signal output processing. The proposed methodology and potential clinical applications are discussed.
Autofluorescence spectroscopy of cutaneous neoplasia under ultraviolet, visible and near infrared excitation
2020
We investigated melanin-pigmented skin samples ex vivo, of benign and dysplastic nevi, as well as malignant melanoma, obtained after surgical excision, containing so called safety areas, where a normal skin could be observed, to obtain a complex and complete view about the feasibility of different excitation sources solely and/or in combination to induce fluorescence signal useful for diagnosis of pigmented cutaneous neoplasia. Using the specialized multispectral analysis of the data obtained by fluorescence using excitation in broad spectral range, covering ultraviolet, visible and near-infrared spectral range, contribute considerably to the both the fundamental determination of tumour tis…
Lattice-Matched GaN–InAlN Waveguides at $\lambda=1.55\ \mu$m Grown by Metal–Organic Vapor Phase Epitaxy
2008
We report on the demonstration of low-loss, single-mode GaN-InAlN ridge waveguides (WGs) at fiber-optics telecommunication wavelengths. The structure grown by metal-organic vapor phase epitaxy contains AlInN cladding layers lattice-matched to GaN. For slab-like WGs propagation losses are below 3 dB/mm and independent of light polarization. For 2.6-mum-wide WGs the propagation losses in the 1.5- to 1.58-mum spectral region are as low as 1.8 and 4.9 dB/mm for transverse-electric- and transverse-magnetic-polarization, respectively. The losses are attributed to the sidewall roughness and can be further reduced by the optimization of the etching process.
Efficient unidirectional polarization-controlled excitation of surface plasmon polaritons
2014
Efficient excitation of surface plasmon polaritons (SPPs) remains one of the most challenging issues in areas of plasmonics related to information communication technologies. In particular, combining high SPP excitation efficiency and acceptance of any polarization of incident light appeared to be impossible to attain due to the polarized nature of SPPs. Here we demonstrate plasmonic couplers that represent arrays of gap SPP resonators producing upon reflection two orthogonal phase gradients in respective linear polarizations of incident radiation. These couplers are thereby capable of efficiently converting incident radiation with arbitrary polarization into SPPs that propagate in orthogon…
Chirped fibre Bragg gratings for phased-array antennas
1997
A variable delay line for phased-array antennas based on a chirped fibre Bragg grating is demonstrated. The time delay of a microwave modulating signal is modified by scanning in wavelength a chirped grating. In this initial experiment, time delay variations up to 556 ps have been achieved using a grating of 0.4 nm bandwidth and 6 cm length and modulating in the frequency range 390 MHz-5.20 GHz.