Search results for "absorptio"
showing 10 items of 2815 documents
Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten
1997
PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…
Effect of Training-Induced Changes in Achilles Tendon Stiffness on Muscle–Tendon Behavior During Landing
2018
During rapid deceleration of the body, tendons buffer part of the elongation of the muscle–tendon unit (MTU), enabling safe energy dissipation via eccentric muscle contraction. Yet, the influence of changes in tendon stiffness within the physiological range upon these lengthening contractions is unknown. This study aimed to examine the effect of training-induced stiffening of the Achilles tendon on triceps surae muscle–tendon behavior during a landing task. Twenty-one male subjects were assigned to either a 10-week resistance-training program consisting of single-leg isometric plantarflexion (n = 11) or to a non-training control group (n = 10). Before and after the training period, plantarf…
Long Term Leisure Time Physical Activity Has a Positive Effect on Bone Mass Gain in Girls
2009
The purpose of this 7-year prospective longitudinal study was to examine whether the level and consistency of leisure-time physical activity (LTPA) during adolescence affected the bone mineral content (BMC) and bone mineral density (BMD) attained at early adulthood. The study subjects were 202 Finnish girls who were 10 to 13 years of age at baseline. Bone area (BA), BMC, and BMD of the total body (TB), total femur (TF), and lumbar spine (L2–L4) were assessed by dual-energy X-ray absorptiometry (DXA). Scores of LTPA were obtained by questionnaire. Girls were divided into four groups: consistently low physical activity (GLL), consistently high (GHH), and changed from low to high (GLH) and fro…
Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden
2008
OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…
Operator-Related Errors and Pitfalls in Dual Energy X-Ray Absorptiometry: How to Recognize and Avoid Them.
2020
Dual-energy X-ray absorptiometry (DXA) is the most common modality for quantitative measurements of bone mineral density. Nevertheless, errors related to this exam are still very common, and may significantly impact on the final diagnosis and therapy. Operator-related errors may occur during each DXA step and can be related to wrong patient positioning, error in the acquisition process or in the scan analysis. The aim of this review is to provide a practical guide on how to recognize such errors in spine and hip DXA scan and how to avoid them, also presenting some of the most common artifacts encountered in clinical practice.
Multiphoton Absorption of Myoglobin Nitric-Oxide complex: Relaxation by D-NEMD of a Stationary State
2012
ABSTRACT: The photodissociation and geminate recombination of nitric oxide in myoglobin, under continuous illumination, is modeled computationally. The relaxation of the photon energy into the protein matrix is also considered in a single simulation scheme that mimics a complete experimental setup. The dynamic approach to non-equilibrium molecular dynamics is used, starting from a steady state, to compute its relaxation to equilibrium. Simulations are conducted for the native form of sperm whale myoglobin and for two other mutants, V68W and L29F, illustrating a fair diversity of spatial and temporal geminate recombination processes. Energy flow to the heme and immediate protein environment …
The impact of Nordic walking on bone properties in postmenopausal women with pre-diabetes and non-alcohol fatty liver disease
2021
This study investigated the impact of Nordic walking on bone properties in postmenopausal women with pre-diabetes and non-alcohol fatty liver disease (NAFLD). A total of 63 eligible women randomly participated in the Nordic walking training (AEx, n = 33), or maintained their daily lifestyle (Con, n = 30) during intervention. Bone mineral content (BMC) and density (BMD) of whole body (WB), total femur (TF), femoral neck (FN), and lumbar spine (L2-4) were assessed by dual-energy X-ray absorptiometry. Serum osteocalcin, pentosidine, receptor activator of nuclear factor kappa-B ligand (RANKL) levels were analyzed by ELISA assay. After an 8.6-month intervention, the AEx group maintained their BM…
Second Harmonic Emission From Dielectric Nanoresonators in the Absorption Regime
2023
We study second harmonic generation in dielectric nanocylinders as a function of the wavelength of the incident field and geometrical dimensions. Uncommonly, we consider a spectral range in which the emitted nonlinear signal is partially absorbed by the dielectric. Surprisingly, we reveal that the second harmonic efficiency does not decrease as the imaginary part of the complex dielectric refractive index increases. Indeed, the presence of higher order multipoles supported by the resonators at the fundamental wavelength can significantly boost the generated second harmonic signal even in the dielectric absorption spectral region achieving nonlinear efficiency of the same order of magnitude …
Third order nonlinear optical properties of novel TetrathiafulvalenePhenanthroline based dyads
2011
The non-linear optical properties of π-conjugated organic molecules such as TTF and their derivatives have recently gained particular interest due to their extended π-system and the strong electron donating character. The knowledge of the nonlinear optical response, as well as the impact of the charge transfer on the nonlinearity is very important. As such systems can be used in a variety of applications. In this study we investigate the nonlinear absorption of novel tetrathiafulvalene-phenanthroline based dyads by means of the Z-scan technique.
Fundamental movement skill proficiency and body composition measured by dual energy X-ray absorptiometry in eight-year-old children
2014
Objective: The main aim was to examine the association between fundamental movement skills (FMS) and objectively measured body composition using dual energy X-ray absorptiometry (DXA). Methods: Study of 304 eight-year-old children in Finland. FMS were assessed with the Test of Gross Motor Development, 2nd ed. (TGMD-2). Total body fat percentage (BF%), abdominal region fat percentage (AF%), and fat-free mass (FFM) were assessed by DXA. Waist circumference, height and weight were measured and International Obesity Task Force (IOTF) cut-off values for BMI were used for the definition of healthy weight and overweight/obesity. Results: Better FMS proficiency (object-control, locomotor, total FMS…