Search results for "addition"
showing 10 items of 933 documents
Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determi…
1997
Abstract The aim of this report is to demonstrate the usefulness of the HPSAM in all instances where the determination of two analytes requires the use of an absorbent reagent, particularly when it does not present a constant analytical signal because of its consumption. This problem can be treated as a ternary mixture by the HPSAM method and then, the fundamentals of the method for resolving these kind of mixtures can be applied. The method can calculate the concentration of one species from spectral data at two wavelengths where the two other species present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. The…
Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…
2010
A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…
A chemometric study of the simultaneous determination of calcium and magnesium in natural waters
1999
A method for the simultaneous spectrophotometric determination of calcium and magnesium in mineral waters with an FIA system is tested. The method is based on the reaction between the analytes and arsenazo(III) at pH 8.5. The calculations of the amounts of both analytes in the samples are carried out with the H-point standard addition method (HPSAM) for ternary mixtures, and with a partial least squares (PLS) model after a proper variable selection. The results obtained for the determination of calcium were comparable using both methods. The employment of the HPSAM brings to our attention the influence of the calcium concentration in the sample to the development of the reaction between mag…
Development of the H-point standard additions method for analyte determinations in unknown matrix
1993
Abstract The development of the H-point standard additions method is proposed in order to obtain the unbiased analyte concentration when the matrix of the sample is completely unknown. A spectral region where the interferent behaviour can be considered linear at three wavelengths must be chosen. The method uses the analytical signal data at these three wavelengths, usually situated in the maxima region of the analyte. Two procedures are proposed in order to know and to locate this behaviour for the unknown interferent. Several binary and ternary mixtures of phenol, 4-chlorophenol and 4-chloro-3-methylphenol as representative examples have been assayed, with accurate (less than 3% relative e…
Generalised H-point standard addition method for the isolation of the analyte signal from the sample signal when coelution of unknown compounds occur…
1999
The generalised H-point standard addition method (GHPSAM) is proposed for isolating the analytical signal of an analyte from the signal of an unknown sample. Samples containing two and three coeluting compounds have been analysed. The accuracy of the predictions depends on the shape of the analyte and interferent spectra but not on the degree of chromatographic overlap. This methodology involves the location of linear intervals for the unknown interference spectrum from the spectrum of the sample. Once the linear interval has been found the selection of three wavelengths within the interval will allow the cancellation of the signal of the unknown interferent. The method has been applied to …
Quantitative electron probe microanalysis of metallic oxide mixtures applying an empirical calibration technique
1997
Abstract An analytical procedure is proposed for the independent quantitative chemical analysis of each element in the presence of other elements in the matrix of a sample by Energy Dispersive Electron Probe Microanalysis. For this purpose, an empirical calibration technique (which we shall call here the JABO method), which studies the variation of the X-ray intensities in terms of the analyte concentration in a chemical system with a complex matrix, is established. The methodology consists of the modification of the unknown sample by addition of a diluent, an internal standard and the analyte itself (dilution-addition method). A mathematical model is proposed to calculate the K parameters …
The H-point and generalized H-point standard additions methods for flow injection procedures.
1997
This paper establishes the fundamentals of the H-point standard additions method (HPSAM) and generalized H-point standard additions method (GHPSAM) in the flow injection technique. Two kinds of analytical signals can be employed, FIA peaks and spectra. Different analytical problems have been studied: determinations of one analyte in the presence or absence of matrix effect when different blank features are present, and determination of two analytes in the presence of blank bias error affecting the development of one of them. The determination of chloride with mercury thiocyanate which presents a matrix effect, and the determinations of calcium and/or magnesium with arsenazo III are examined…
Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations
1998
The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…
Polyacrylonitrile block copolymers for the preparation of a thin carbon coating around TiO2 nanorods for advanced lithium-ion batteries.
2013
Herein, a new method for the realization of a thin and homogenous carbonaceous particle coating, made by carbonizing RAFT polymerization derived block copolymers anchored on anatase TiO2 nanorods, is presented. These block copolymers consist of a short anchor block (based on dopamine) and a long, easily graphitizable block of polyacrylonitrile. The grafting of such block copolymers to TiO2 nanorods creates a polymer shell, which can be visualized by atomic force microscopy (AFM). Thermal treatment at 700 °C converts the polyacrylonitrile block to partially graphitic structures (as determined by Raman spectroscopy), establishing a thin carbon coating (as determined by transmission electron m…
Stabilizing nanostructured lithium insertion materials via organic hybridization: A step forward towards high-power batteries
2014
Abstract Herein, we present the electrochemical characterization of carbon-coated TiO 2 nanorods, obtained by carbonizing RAFT (reversible addition fragmentation chain transfer) polymerization derived block copolymers anchored on anatase TiO 2 nanorods. These carbon-coated TiO 2 nanorods show an improved electrochemical performance in terms of first cycle reversibility, specific capacity, cycling stability, and high rate capability. More importantly, however, the structural disordering observed in the uncoated TiO 2 nanorods by means of galvanostatic and potentiodynamic cycling as well as ex situ XRD analysis, does not occur for the carbon-coated material. Preventing this structural disorde…