Search results for "ample"
showing 10 items of 2398 documents
Determination of quinolone residues in chicken and fish by capillary electrophoresis-mass spectrometry
2006
A specific pressure-assisted CE-MS method is described for the analysis of five quinolone residues. MS using a single quadrupole is compared with multiple-stage MS using a quadrupole IT (QIT-MS(n)). The procedure involves a common sample preparation by SPE on disposable cartridges. The most suitable electrolyte is 60 mM (NH(4))(2)CO(3) at pH 9.2. Single quadrupole does not provide enough fragmentation to confirm identities according to the current legislation. However, QIT-MS(n) achieves selective fragmentation. Using this method, danofloxacin, enrofloxacin, flumequine, ofloxacin, and pipemidic acid are analyzed in fortified samples of chicken and fish. Recoveries at levels of 50 ng/g were …
BEHAVIOUR OF GRAPHITIZED CARBON BLACK IN THE EXTRACTION OF POLAR NON-IONIC NITROGEN-CONTAINING PESTICIDES. A CHECKING OF HYPOTHESES
2000
Graphitized Carbon Black (GCB) extractive cartridges are evaluated for on-line coupling with a C8 analytical column to determine eleven carbamates and one carboximide pesticide from spiked deionized water at the 1.2 μg/L level. Several experiments were carried out to ascertain whether GCB saturation, pesticide degradation on the surface, existence of by-pass channels, mobility among the bulk cartridge, or strong retention on the surface interfere with the determination of pesticides. Problems in on-line CGB elution are partially solved by modifying the acetonitrile/water gradient to contain a front of 100% acetonitrile for a few seconds. Eluting the same GCB cartridges off-line with dichlor…
Solid phase extraction of amines
2005
Abstract The objective of this paper is to provide information about solid phase extraction (SPE) as an alternative to liquid–liquid extraction of amines from several matrices. Different sorbents ranging from non-polar phases, such as C 18 silica to more polar such as cyanopropylsilica (CN) have been tested for analysis of aliphatic amines as monoamines, diamines and polyamines. Phenylalkylamines such as amphetamine or methamphetamine and heterocyclic amines such as histamine or cephalosporins (which also contain a carboxylic group), have also been studied. The different steps involved in the extraction procedure have been tested (conditioning, retention, pre-concentration, washing and elut…
Molecularly imprinted polymer-based device for field collection of oral fluid samples for cocaine identification.
2020
In this paper, a low-cost, rapid, easy, and potentially portable tool for the identification of cocaine and its semi-quantitative determination in oral fluid has been proposed. A field collection device has been designed, based on a cotton pad with an indicator and a molecularly imprinted polymer (MIP) sorbent, to selective retain cocaine from oral fluid components. After sample collection, cocaine is transferred by using phosphate buffer to the MIP and then eluted with 2-propanol. The obtained extract is analysed by ion mobility spectrometry (IMS), providing a cut-off value of 20 µg L-1 that identifies 100 % true-positive and 95 % true-negative samples. The MIP-IMS procedure has been valid…
Rapid method for analysis of nicotine and nicotine-related substances in chewing gum formulations
1998
Abstract Based on environmental requirements and demands for a high throughput a rapid method for the analysis of nicotine and nicotine-related substances in chewing gum formulations was developed. The method is based on sample preparation through liquid–liquid extraction followed by reversed-phase HPLC using gradient elution. It allowed up to nine analytes to be determined within 15 min, including the sample preparation, and was considered as accurate and robust.
Extraktionschromatographische trennung der freien porphyrine auf tri-n-butylphosphat-s?ulen im pH-gradienten
1969
Abstract The method described allows the separation of the free porphyrins on a tri-n-butyl phosphate (TBP) column by elution with a pH gradient. The prophyrins are eluted from the column at discrete pH values (xD) according to the number of carboxyl groups in the side chains. Separation of isomers could not be observed under the conditions used. The xD values indicate the centre of the pH-interval, in which the dissociation of the carboxyl groups occurs. This finding could be confirmed by spectro-photometric measurements. By combining the method proposed with the method of separation by extraction chromatography in the TBP/IN HCl partition system and the thin-layer technique in the 2,6-lut…
Solid-phase extraction of quaternary ammonium herbicides
2000
This paper highlights recent advances in the solid-phase extraction (SPE) of quaternary ammonium herbicides in water, soil, plant and biological samples. After a brief introduction summarizing the properties of quaternary ammonium herbicides and the difficulties involved in measuring them, attention is paid primarily to solid supports used for isolation and concentration, pre-treatments required for the different matrices, and eluents applied for quantitative desorption of these analytes. The determination techniques used after SPE and applications of the proposed SPE methodology are also briefly discussed.
Levels in the interpretive optimisation of selectivity in high-performance liquid chromatography: a magical mystery tour.
2006
Interpretive approaches for selectivity optimisation, which are those supported by retention models, are able to exploit efficiently the capabilities of the chromatographic system. The resolution of a mixture is usually faced in a first trial by looking for a unique experimental condition, able to resolve all compounds in the sample. If this is not possible, the problem can be outlined with less ambitious aims, focusing on only some compounds. In an extreme case, a single analyte can be individually optimised. Current strategies that give answer to the different goals pursued in the analysis, which are classified as total, partial and specific, are reviewed. Optimisation oriented to deconvo…
Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography-electrospray ionization mass spectrometry and integrated sam…
2000
A novel restricted access cation exchanger with sulphonic acid groups at the internal surface was proven to be highly suitable in the sample clean up of peptides on-line coupled to HPLC-electrospray ionization (ESI)-MS. Neuropeptide Y (NPY) and several of its fragments in plasma were subjected to the sample clean-up procedure. The peptides were eluted by a step gradient from the restricted access column, applying 10 mM phosphate buffer pH 3.5 from 5 to 20% (v/v) of acetonitrile with 1 M NaCl and transferred to a Micra ODS II column (33x4.6 mm). The separation of the peptides and their fragments was performed by a linear gradient from 20 to 60% (v/v) acetonitrile in water with 0.1% formic ac…
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…