Search results for "aorta"
showing 10 items of 458 documents
Cardiovascular disease in aging: an overview on thoracic aortic aneurysm as an emerging inflammatory disease
2017
Medial degeneration associated with thoracic aortic aneurysm and acute aortic dissection was originally described by Erdheim as a noninflammatory lesion related to the loss of smooth muscle cells and elastic fibre fragmentation in the media. Recent evidences propose the strong role of a chronic immune/inflammatory process in aneurysm evocation and progression. The coexistence of inflammatory cells with markers of apoptotic vascular cell death in the media of ascending aorta with aneurysms and type A dissections raises the possibility that activated T cells and macrophages may contribute to the elimination of smooth muscle cells and degradation of the matrix. On the other hand, several infla…
Genotyping strategy of SMAD-3 rs3825977 gene variant for a differential management of ascending aorta aneurysm in women people: Gender oriented diagn…
2020
Abstract Background and objectives The research of opportune strategies for facilitating the management of complex pathologies, such as ascending aorta aneurysm (AAA), currently represents the principal object of clinicians, clinical pathologists included. Herein, we propose genotyping of gene variants related to TGF-β pathway as useful strategy to improve the complex AAA management, exclusively based on imaging evaluations. Precisely, we investigated four functional SNPs in SMAD and VEGF genes, encoding molecules able to modulate functions and cross-talks of TGF-β pathway. Populations and methods Our study included 92 individuals (70 men (76%) and 22 (24%) women; mean age: 71.4 ± 2.6 years…
Leisure-time physical activity and artery lumen diameters: A monozygotic co-twin control study
2010
Exercise is thought to increase the diameter of the conduit arteries supplying the muscles involved. We studied the effects of a physically active vs inactive lifestyle on artery diameters in monozygotic (MZ) twin pairs discordant over 30 years for leisure-time physical activity habits. In a population-based co-twin control study design, six middle-aged (50-65 years) same-sex MZ twin pairs with long-term discordance for physical activity were comprehensively identified from the Finnish Twin Cohort (TWINACTIVE study). Discordance was initially defined in 1975 and the same co-twin remained significantly more active during the 32-year follow-up. The main outcomes were arterial lumen diameters …
CT-Determined Maximum Pulmonary Artery to Ascending Aorta Diameter Ratio in Nonsevere COVID-19 Patients
2021
Quality Control in 3D Printing: Accuracy Analysis of 3D-Printed Models of Patient-Specific Anatomy
2021
As comparative data on the precision of 3D-printed anatomical models are sparse, the aim of this study was to evaluate the accuracy of 3D-printed models of vascular anatomy generated by two commonly used printing technologies. Thirty-five 3D models of large (aortic, wall thickness of 2 mm, n = 30) and small (coronary, wall thickness of 1.25 mm, n = 5) vessels printed with fused deposition modeling (FDM) (rigid, n = 20) and PolyJet (flexible, n = 15) technology were subjected to high-resolution CT scans. From the resulting DICOM (Digital Imaging and Communications in Medicine) dataset, an STL file was generated and wall thickness as well as surface congruency were compared with the original …
Estudio de la evolución del sellado distal ilíaco en el tratamiento endovascular de la aorta abdominal
2018
Introducción: En las endoprótesis aórticas (EVAR) existen diferentes opciones y teorías respecto al sellado distal para ilíacas comunes dilatadas y controversia en cuanto a su evolución. Objetivo: conocer los resultados, la evolución del sellado distal en EVAR y formalizar un algoritmo terapéutico. Pacientes y metodología: Se realiza un análisis retrospectivo de los pacientes sometidos a EVAR, en el Hospital Universitario Doctor Peset, entre 2007 y 2015. La investigación consta de 5 estudios. Los tres primeros estudios son comparativos: • El primero compara los resultados y la evolución del sellado entre ilíaca externa y común tras el cambio de estrategia en nuestro centro (sellado en ilíac…
CT angiography for the assessment of EVAR complications : a pictorial review
2022
Aortic aneurysm; Blood vessel prosthesis implantation; Endovascular procedures Aneurisma aórtico; Implantación de prótesis de vasos sanguíneos; Procedimientos endovasculares Aneurisma aòrtic; Implantació de pròtesis de vasos sanguinis; Procediments endovasculars Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complication…
Periscopes, chimneys, sandwich and VORTEC to facilitate abdominal and thoracoabdominal aortic aneurysm repair
2012
The VORTEC (VIABAHN open revascularization technique) and the chimney graft technique are tools with which to maintain or restore blood flow to the aortic branches and can be used intentionally or as a bailout procedure in open surgery or endovascular procedures. VORTEC is a stent graft-based vascular connection technique that achieves end-to-end anastomosis configuration; it is especially useful when the traditional suture technique proves (can be) cumbersome. It is also a speedy tool with virtually no blood flow interruption and no anastomotic bleeding, and patency rates compare favorably with sutured anastomosis. The chimney/periscope, as well as the sandwich graft technique (CHIMPES), i…
Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft
2017
Abstract Objective One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human lipo…
Effect of aneurysm on the mechanical dissection properties of the human ascending thoracic aorta
2012
Objectives: The acute dissection of an ascending thoracic aortic aneurysm (ATAA) represents a devastating separation of elastic layers occurring when the hemodynamic loads on the diseased wall exceed the adhesive strength between layers. At present, the mechanics underlying aortic dissection are largely unclear, and the biomechanical delamination properties of the aneurysmal aorta are not defined. Individuals with bicuspid aortic valve (BAV) are particularly predisposed to ascending aortic aneurysm formation, with a marked risk of aortic dissection. The purpose of this study was to evaluate and compare the dissection properties of nonaneurysmal and aneurysmal human ascending thoracic aorta …