Search results for "asma"

showing 10 items of 4204 documents

Polymorphism of amyloid-beta fibrils and its effects on human erythrocyte catalase binding.

2009

The Alzheimer's amyloid-beta (Abeta) peptide exists as a number of naturally occurring forms due to differential proteolytic processing of its precursor molecule. Many of the Abeta peptides of different lengths form fibrils in vitro, which often show polymorphisms in the fibril structure. This study presents a TEM based analysis of fibril formation by eighteen different Abeta peptides ranging in length from 5 to 43 amino acids. Spectrophotometric analysis of Congo red binding to the fibrillar material has been assessed and the binding of human erythrocyte catalase (HEC) to Abeta fibrils has also been investigated by TEM. The results show that a diverse range of Abeta peptides form fibrils a…

AmyloidErythrocytesGeneral Physics and AstronomyPeptidemacromolecular substancesPlasma protein bindingFibrilchemistry.chemical_compoundMicroscopy Electron TransmissionStructural BiologyHumansGeneral Materials Sciencechemistry.chemical_classificationbiologyStaining and LabelingCongo RedCell BiologyCatalaseIn vitroAmino acidCongo redPolymorphism (materials science)BiochemistrychemistryCatalaseSpectrophotometrybiology.proteinProtein BindingMicron (Oxford, England : 1993)
researchProduct

Cholesterol facilitates interactions between α‐synuclein oligomers and charge‐neutral membranes

2015

AbstractOligomeric species formed during α-synuclein fibrillation are suggested to be membrane-disrupting agents, and have been associated with cytotoxicity in Parkinson’s disease. The majority of studies, however, have revealed that the effect of α-synuclein oligomers is only noticeable on systems composed of anionic lipids, while the more physiologically relevant zwitterionic lipids remain intact. We present experimental evidence for significant morphological changes in zwitterionic membranes containing cholesterol, induced by α-synuclein oligomers. Depending on the lipid composition, model membranes are either unperturbed, disrupt, or undergo dramatic morphological changes and segregate …

AmyloidParkinson's diseaseFluorescent DyeBiophysicsPlasma protein bindingBiochemistryOligomerProtein Structure SecondaryMultiphoton microscopyMembrane phase separationCell membranechemistry.chemical_compoundGeneticStructural Biology2-NaphthylamineLaurdan fluorescenceGeneticsFluorescence microscopemedicineMolecular BiologyFluorescent DyesLaurateα-SynucleinMembranesChemistryMedicine (all)2-NaphthylamineCell MembraneMembraneCell BiologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CholesterolMembranemedicine.anatomical_structureBiophysicBiochemistryStructural biologyOligomeralpha-SynucleinParkinson’s diseaseProtein MultimerizationLaurdanLauratesProtein BindingFEBS Letters
researchProduct

Determination of antimony, arsenic, bismuth and copper by inductively coupled plasma atomic emission spectrometry in the electrorefining of copper

1996

Inductively coupled plasma atomic emissionspectrometry (ICP-AES) has been applied as a rapid and routine method for the analysis of process electrolytes in the electrorefining of copper. Antimony, arsenic, bismuth and copper have been selected as major electrolyte constituents. For these elements profound statistical studies of spectral and interelement effects have been carried out. For As, Bi and Sb two analyte wavelengths have been selected, and for Cu one relatively insensitive analyte line has been chosen due to the high Cu concentration in samples. Best analytical lines were: As at 193.759 nm, Bi at 306.772 nm, Sb at 206.833 nm and Cu at 216.953 nm. Multiple linear regression proved t…

AnalyteAntimonyChemistryAnalytical chemistrychemistry.chemical_elementElectrolyteInductively coupled plasmaBiochemistryCopperArsenicAnalytical ChemistryElectrowinningBismuthAnalytical and Bioanalytical Chemistry
researchProduct

The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…

2009

Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…

AnalyteChromatographyAcoustics and UltrasonicsOrganic ChemistryAnalytical chemistrychemistry.chemical_elementZincInorganic Chemistrychemistry.chemical_compoundChromiumDigestion (alchemy)chemistryFly ashChemical Engineering (miscellaneous)Environmental ChemistryAqua regiaRadiology Nuclear Medicine and imagingInductively coupled plasmaMicrowave digestionUltrasonics sonochemistry
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

AnalyteChromatographyChemistryAnalytical chemistrychemistry.chemical_elementPlasmaAnalytical ChemistryMatrix (chemical analysis)Fly ashStandard additionLinear regressionInductively coupled plasmaSpectroscopyArsenicJournal of Analytical Atomic Spectrometry
researchProduct

A preliminary study on the stability of benzodiazepines in blood and plasma stored at 4 degrees C.

1997

An approach to determine the stability of benzodiazepines and some of their metabolites (n = 13) by means of a routinely applied gas chromatographic method using electron capture detection was made in this preliminary study. Validation data of the method are given. Spiked blood and plasma samples were stored at 4 degrees C and analysed at selected times up to 240 days. The concentrations of all analytes had decreased to at least 60% of the original levels at the end of the observation period. A clear pattern of breakdown could not be established. The data obtained suggest that results from long-term stored samples should be interpreted cautiously. Further investigations concerning the stabi…

AnalyteChromatographyChromatography GasPlasma samplesChemistryObservation periodForensic toxicologyPlasmaForensic MedicinePathology and Forensic MedicineSpecimen HandlingSubstance Abuse DetectionBenzodiazepinesPlasmaBloodReference ValuesRefrigerationReference valuesLinear ModelsHumansGas chromatographyInternational journal of legal medicine
researchProduct

First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas

2014

The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…

AnalyteHydrogenAnalytical chemistrychemistry.chemical_elementOxygenAnalytical ChemistryTriple quadrupole mass spectrometerIonAmmoniachemistry.chemical_compoundchemistryIsobaric processInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Electrochemical pH Control at Gold Nanowires

2018

In this work, interdigitated arrays of nanowire electrodes are used with one array acting as the working electrode while the other is used to generate the required protons. Finite element simulations of the pH control electrodes were performed to provide insight on the generation and subsequent diffusion of protons. This informed the inter-tine spacing of the electrodes used.. This electrochemical pH control method was then used to enable the detection of analytes of interest.

AnalyteWorking electrodeMaterials sciencePhysics::Instrumentation and Detectorsbusiness.industry020209 energy010401 analytical chemistryPh controlNanowire02 engineering and technologypH control gold nanowire heavy metal in situ simulationElectrochemistry01 natural sciencesFinite element method0104 chemical sciencesSettore ING-IND/23 - Chimica Fisica ApplicataPhysics::Plasma PhysicsElectrode0202 electrical engineering electronic engineering information engineeringOptoelectronicsDiffusion (business)business2018 IEEE 18th International Conference on Nanotechnology (IEEE-NANO)
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Transmembrane electrochemistry of erythrocytes: Direct electrochemical test for detecting hemolysis in whole blood

2016

A rapid method for detecting hemolysis in whole blood based on a direct electrochemical assay either in venous blood and finger blood, respectively at glassy carbon and screen-printed graphite electrodes is described. The presence of hemolysis is detected from characteristic voltammetric signatures associated to Fe-heme units in healthy and hemolyzed erythrocytes. The voltammetric response of blood was also investigated using scanning electrochemical microscopy (SECM) and scanning tunneling microscopy (STM) and involved transmembrane electrochemistry of erythrocytes superimposed to molecular electrochemistry of heme-containing proteins and heme fragments in the plasma. Voltammetric testing …

Analytical chemistry02 engineering and technologyGlassy carbon010402 general chemistryElectrochemistry01 natural sciencesScanning electrochemical microscopyBlood plasmaMaterials ChemistrymedicineElectrochemistryElectrical and Electronic EngineeringInstrumentationWhole bloodHemolysis indexDetection limitChromatographyChemistryMetals and AlloysVenous blood021001 nanoscience & nanotechnologyCondensed Matter Physicsmedicine.diseaseHemolysis0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsVenous bloodFinger blood0210 nano-technology
researchProduct