Search results for "atomic"

showing 10 items of 27529 documents

Synthesis of ZnO–Ag2CO3–Fe3O4@rGO core–shell structure: magnetically separable photocatalyst for degradation of MB using the Box–Behnken design

2020

In this work, a simple microwave method was utilized to prepare ZnO sheet linked with Fe3O4@rGO core–shell and of Ag2CO3 through formation of the quadri-photocatalytic with high activity. The microstructure, morphology, spectroscopic, and magnetic characteristics of the prepared samples were assessed using XRD, SEM, PL, TEM, FT-IR, DLS, and VSM analysis. The photocatalytic activity of the material was evaluated for photodegradation of methylene blue dye under the UV and visible light with home-made photoreactor. The response surface method in a Box–Behnken design was utilized to design the experiments. The parameters affecting the efficiency of the degradation including, pH (5–9), photocata…

010302 applied physicsMaterials scienceCondensed Matter PhysicsMicrostructure01 natural sciencesBox–Behnken designAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsCatalysischemistry.chemical_compoundchemistryChemical engineering0103 physical sciencesPhotocatalysisDegradation (geology)Fe3O4 magnetically separable photocatalyst photocatalysis photodegradationElectrical and Electronic EngineeringPhotodegradationMethylene blueVisible spectrumJournal of Materials Science: Materials in Electronics
researchProduct

Quasi-antiferromagnetic multilayer stacks with 90 degree coupling mediated by thin Fe oxide spacers

2019

We fabricated quasiantiferromagnetic (quasi-AFM) layers with alternating antiparallel magnetization in the neighboring domains via 90° magnetic coupling through an Fe-O layer. We investigated the magnetic properties and the relationship between the magnetic domain size and the 90° magnetic coupling via experiments and calculations. Two types of samples with a Ru buffer and a (Ni80Fe20)Cr40 buffer were prepared, and we found that with the NiFeCr buffer, the sample has a flatter Fe-O layer, leading to stronger 90° magnetic coupling and a smaller domain size compared with the Ru buffer sample. This trend is well explained by the bilinear and biquadratic coupling coefficients, A12 and B12, in L…

010302 applied physicsMaterials scienceCondensed matter physicsMagnetic domainAtomic force microscopy530 PhysicsOxideGeneral Physics and Astronomy02 engineering and technology021001 nanoscience & nanotechnology530 Physik01 natural sciencesInductive couplingBuffer (optical fiber)Magnetizationchemistry.chemical_compoundchemistry0103 physical sciencesAntiferromagnetism0210 nano-technologyAntiparallel (electronics)
researchProduct

Arsenic diffusion in relaxedSi1−xGex

2003

The intrinsic As diffusion properties have been determined in relaxed ${\mathrm{Si}}_{1\ensuremath{-}x}{\mathrm{Ge}}_{x}$ epilayers. The properties were studied as a function of composition x for the full range of materials with $x=0,$ 0.20, 0.35, 0.50, 0.65, 0.8, and 1. The activation enthalpy ${E}_{a}$ was found to drop systematically from 3.8 eV $(x=0)$ to 2.4 eV $(x=1).$ Comparisons with other impurity atom- and self-diffusion results in Si, Ge, and SiGe show that both interstitials and vacancies contribute as diffusion vehicles in the composition range $0l~xl~0.35$ and that vacancy mechanism dominates diffusion in the composition range $0.35lxl~1.$

010302 applied physicsMaterials scienceCondensed matter physicschemistryImpurityVacancy defect0103 physical sciencesEnthalpychemistry.chemical_elementAtomic physics010306 general physics01 natural sciencesArsenicPhysical Review B
researchProduct

How activator ion concentration affects spectroscopic properties on Ba4Y3F17: Er3+, Yb3+, a new perspective up-conversion material

2018

Abstract Ba4Y3F17 with Er3+ and Yb3+, a promising material for up-conversion luminescence, was synthesized. Excellent isomorphic capacity was detected. Low-temperature measurements show that erbium ions are incorporated in multiple lattice positions, which is inconsistent with the current model of Ba4Y3F17 crystal lattice structure. Activator ion concentration has a different impact on 4S3/2 and 4F9/2, states (for the green and red luminescence, respectively) depopulation. Energy transfer from Er3+ 4S3/2 state to Yb3+ is observed even at low temperature (15 K) while Er-Er cross-relaxation is observed from 120 K and above. Yb3+ concentration has a great impact to red-to-green up-conversion l…

010302 applied physicsMaterials scienceEnergy transferBiophysicsAnalytical chemistryQuantum yield02 engineering and technologyGeneral ChemistryCrystal structure021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciencesBiochemistryAtomic and Molecular Physics and OpticsIonLattice (order)0103 physical sciencesActivator (phosphor)Up conversion0210 nano-technologyLuminescenceJournal of Luminescence
researchProduct

A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions

2019

Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…

010302 applied physicsMaterials scienceEquivalent series resistanceAmplifierPenning trap01 natural sciences7. Clean energySignalFourier transform ion cyclotron resonance010305 fluids & plasmasIonCrystal0103 physical sciencesAtomic physicsInstrumentationSensitivity (electronics)Review of Scientific Instruments
researchProduct

Experimental evidence on photo-assisted O− ion production from Al2O3 cathode in cesium sputter negative ion source

2020

The production of negative ions in cesium sputter ion sources is generally considered to be a pure surface process. It has been recently proposed that ion pair production could explain the higher-than-expected beam currents extracted from these ion sources, therefore opening the door for laser-assisted enhancement of the negative ion yield. We have tested this hypothesis by measuring the effect of various pulsed diode lasers on the O − beam current produced from Al 2O 3 cathode of a cesium sputter ion source. It is expected that the ion pair production of O − requires populating the 5d electronic states of neutral cesium, thus implying that the process should be provoked only with specific …

010302 applied physicsMaterials scienceGeneral Physics and Astronomy02 engineering and technologyPhoton energy021001 nanoscience & nanotechnologyLaser01 natural sciencesCathodeIon sourceIonlaw.inventionPhysics::Plasma PhysicslawSputtering0103 physical sciencesAtomic physics0210 nano-technologyBeam (structure)DiodeJournal of Applied Physics
researchProduct

Photoelectron Emission from Metal Surfaces Induced by VUV-emission of Filament Driven Hydrogen Arc Discharge Plasma

2015

Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.

010302 applied physicsMaterials scienceHydrogenPhysics::Instrumentation and DetectorsFluxchemistry.chemical_elementFOS: Physical sciencesPlasma01 natural sciences7. Clean energyPhysics - Plasma PhysicsIon source010305 fluids & plasmasElectric arcPlasma Physics (physics.plasm-ph)chemistryPhysics::Plasma Physics0103 physical sciencesPhysics::Atomic and Molecular ClustersQuantum efficiencyPhysics::Atomic PhysicsAtomic physicsHydrogen spectral seriesOrder of magnitude
researchProduct

Operating a cesium sputter source in a pulsed mode

2020

A scheme is presented for pulsing of a cesium sputter negative ion source by periodically switching on and off the high voltage driving the sputtering process. We demonstrate how the pulsed ion beam can be used in combination with a pulsed laser (6 ns pulse length) that has a 10 Hz repetition rate to study the photodetachment process, where a negative ion is neutralized due to the absorption of a photon. In such experiments, where the ion beam is used only for a small fraction of the time, we show that the pulsed mode operation can increase the lifetime of a cathode by two orders of magnitude as compared with DC operation. We also investigate how the peak ion current compares with the ion c…

010302 applied physicsMaterials scienceIon beamPulse durationIon currentHigh voltage01 natural sciencesCathode010305 fluids & plasmasIonlaw.inventionPhysics::Plasma PhysicsSputteringlaw0103 physical sciencesAtomic physicsAbsorption (electromagnetic radiation)InstrumentationReview of Scientific Instruments
researchProduct

A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams

2020

An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very stro…

010302 applied physicsMaterials scienceIon beamsyklotronittutkimuslaitteetHighly charged ionchemistry.chemical_elementhiukkaskiihdyttimet01 natural sciences7. Clean energyIon sourceElectron cyclotron resonance010305 fluids & plasmasIonXenonchemistry0103 physical sciencesIrradiationAtomic physicsInstrumentationBeam (structure)
researchProduct

The effect of plasma instabilities on the background impurities in charge breeder ECRIS

2017

International audience; Experimental observations of plasma instabilities in the 14.5 GHz PHOENIX charge breeder ECRIS are summarized. It has been found that the injection of 133Cs+ or 85Rb+ into oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which results to sputtering of the surfaces exposed to the plasma, followed by up to an order of magnitude increase of impurity currents in the extracted n+ charge state distribution. The transition from stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb altering the discharge parameters in 10 - 100 ms time scale, not by a prompt interaction between the incident ion beam and the EC…

010302 applied physicsMaterials scienceIon beamta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Buffer gasCyclotronPlasmaElectroncharge breederplasmafysiikka7. Clean energy01 natural sciences010305 fluids & plasmaslaw.inventionIonECRISSputteringlawIonization0103 physical sciencesAtomic physicsplasma (kaasut)plasma
researchProduct